2.7M Square SUA-CS27 - Street Umbrellas Australia

16 downloads 185 Views 203KB Size Report
Pavers/Tiles. Non-shrink grout. Levelling nuts. See Bolt* and. Slab Note*. Non-shrink grout. Levelling nuts. See Bolt* a
200

TOP HAT aluminium powder coat finish Collar and arm in closed position.

FABRIC, PVC PVDF coated Standard colour, white

37 80

ov er all

2300 minimum

NOTE: Allow up to 50mm sag due to stretch of membrane fabric.

Plan

CABLE S.S. Gr.316 with S.S. fittings

1:100 at A4

Arc of arm when opening.

3200

ARM Ø38 CHS powder coat finish 2250 clear

COLLAR Ø76 CHS powder coat finish (in opened position)

Overall dimensions represent clearance dimensions for the complete umbrella. Membrane dimensions differ, depending on variations in tensioning and fabrication. Dimensions are in millimetres.

BASE PLATE 200x200x12 pl. with Ø50 service hole. 4-M12 hold down bolts at 140mm c/crs. Grade 4.6/s galvanised or stainless steel Gr.316. With dome nuts and levelling nuts.

OPENED POSITION

0

500

2250

SQUARE 2.7m - SUA-CS27 Wind Rating: 33m/sec (120km/h) Rated when umbrella is fully erected. Umbrella weight: 52 kg

POLE Ø60 CHS powder coat finish

1740

1:100 at A4

1380

Elevation

1215

RETAINING ROD stainless steel

1190

2700 overall

Stainless steel sleeve pole protector for length of collar travel.

1000

1500

1860

CLOSED POSITION

2.7m Centre Support Square Umbrella Centre Support - Model SUA-CS27 Centre Support Square Umbrella MODEL: SUA-CS27 Engineering Framing

=

==

Elevation

Natural Ground

140 c/crs

Bolt projection 40 min. 120 max. Embedment 110 min.

40 min 120 max

SUA-CS27 - Pier Footing 4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. Supplied with nuts, washers and levelling nuts. Chemical anchors, at 140 x 140 centres to be 'Hilti HVU', or engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions. Hole to be clean and dry at time of installation.

all er ov

Non-shrink grout

Elevation

80 37

CS27 - Pad Footing

Ø450

1350

F82 fabric central

Anchor bolt location tolerances per Australian Standard AS 4100-1990 - 3mm for anchor bolt centres within an anchor bolt group. - 6mm for adjacent anchor bolt group centres. - Maximum accumulation of 6mm per 30m not to exceed a total of 25mm. - 6mm from anchor bolt group centre to column line centre.

1350

230 embedment (cast in)

4-N16 vertical R6 helix at 300 pitch

150

300

Non-shrink grout

Natural ground

Minimum 60mm cover to all reinforcement Concrete grade to be N25 20mm aggregate size Slump 65mm

2700 overall

Plan

4-M12 Gr.4.6/S galvanised H.D. bolts with nuts and levelling nuts - Cog 100 Bolt projection to suit level of top of paving, tiling, etc 40 min 120 max.

1000

140

grout

430 min overlap

=

==

140

Plan Non-shrink

==

900

=

140

==

Assumed soil conditions: Pad - bearing capacity 100kPa Pier - cu=50kPa (stiff clay)

60 cover

=

Notes: Design wind speed 33m/sec (W33)

140

900

1350

1350

2700 overall

H.D. Bolt Layout Plan

Chemical Anchor Detail

Not to scale

Centre Support Square Umbrella Model:SUA-CS27 Footing Detail

140 c/crs

* H.D. BOLT NOTE Structure pole has 200 x 200 x 12 base plate. 4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. at 140 x 140 centres.

140 c/crs

120 max

See Bolt* and Slab Note*

Non-shrink grout Levelling nuts

Over Pavers 120 max

140 c/crs

* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint.

Pavers/Tiles

Embedment Refer Table

Grout/bedding (no sand)

varies

Pavers/Tiles

Slab Thickness Refer Table

varies

Non-shrink grout

Embedment Refer Table

Slab Thickness Refer Table

120 max.

Levelling nuts

See Bolt* and Slab Note*

Contact SUA Dealer if the slab does not meet any of the requirements.

Under Pavers

Chemical Anchor Fixing to Slab on Ground

On Slab Slab Thickness 100 110 120 130 140 plus

Min. Embedment H.D. Bolts* Chemical Anchor Min. Slab Edge Distance* 80 4-M12 at 140 c/crs 400 Ramset Reo 502 (or Hilti HIT-RE 500) 90 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 100 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 110 400 Hilti HVU 4-M12 at 140 c/crs 110 400 Hilti HVU 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions.

Installation Detail - Model SUA-CS27

1350

2700 overall

See Bolt* and Slab Note*

1350

Embedment Refer Table

Levelling nuts

all er ov 80 37

Slab Thickness Refer Table

Non-shrink grout

1350

1350

2700 overall

H.D. Bolt Layout Plan

Not to scale

Centre Support Square Umbrella Model:SUA-CS27 Existing Slab on Ground

3 mm clearance

140 c/crs

Varies 120 max.

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws. Varies 120 max.

Slab Thickness Refer Table Embedment Refer Table

Pavers/Tiles

Over Pavers

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws. (Counter-sunk option if required) See Ferrule* and Slab Note*

Flexible sealant (Mastic or similar)

* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint.

Non-shrink grout See Ferrule* and Slab Note*

Contact SUA Dealer if the slab does not meet any of the requirements.

At Pavers Rubber grommets, stainless steel grub screws with hex socket or brass flat dome head screws, screwd into ferrule flush with paving to keep ferrule thread clean.

80 37

Slab Thickness Refer Table Embedment Refer Table

140 c/crs

* FERRULE NOTE Ferrules at 140 x 140 centres are M20 stainless steel Gr.316 threaded rods tapped for M12.

Pavers/Tiles

Slab Thickness Refer Table Embedment Refer Table

Grout/bedding (no sand) See Ferrule* and Slab Note*

140 c/crs

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 counter-sunk set screws.

Slab Thickness 100 110 120 130 140 plus

Min. Embedment Ferrules* Chemical Anchor Min. Slab Edge Distance* 80 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 400 90 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 100 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 110 400 Hilti HVU 4-M12 at 140 c/crs 110 400 Hilti HVU 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions.

Ferrule Detail - Model SUA-CS27

1350

Ferrule Fixing with Umbrella Removed

1350

Chemical Anchor Fixing to Slab on Ground

2700 overall

all er ov

On Slab

1350

1350

2700 overall

H.D. Bolt Layout Plan

Not to scale

Centre Support Square Umbrella Model: SUA-CS27 Ferrule Fixing