4.0M Dia SUA-CO40 - Street Umbrellas Australia

1 downloads 195 Views 205KB Size Report
Pavers/Tiles. Non-shrink grout. Levelling nuts. See Bolt* and. Slab Note*. Non-shrink grout. Levelling nuts. See Bolt* a
220

TOP HAT aluminium powder coat finish

4050 overall

3610 minimum

eral l 0 ov 437

Collar and arm in closed position.

Stainless steel sleeve pole protector for length of collar travel.

Plan

1:100 at A4

FABRIC, PVC PVDF coated Standard colour, white

CABLE S.S. Gr.316 with S.S. fittings

NOTE: Allow up to 50mm sag due to stretch of membrane fabric.

ARM Ø38 CHS powder coat finish

Arc of arm when opening.

COLLAR Ø102 CHS powder coat finish (in opened position)

1:100 at A4

OCTAGONAL 4m - SUA-CO40 Wind Rating: 33m/sec (120km/h) Rated when umbrella is fully erected. Umbrella weight: 80kg Overall dimensions represent clearance dimensions for the complete umbrella. Membrane dimensions differ, depending on variations in tensioning and fabrication.

OPENED POSITION

0

1000

1500

1810 2100

770 500

1225

BASE PLATE 200x200x12 pl. with Ø50 service hole. 4-M12 hold down bolts at 140mm c/crs. Grade 4.6/s galvanised or stainless steel Gr.316. With dome nuts and levelling nuts.

740

POLE Ø89 CHS powder coat finish

920

Elevation

3010

2100 clear

RETAINING ROD stainless steel

2000 2140

CLOSED POSITION

4m Centre Support Octagonal Umbrella Model SUA-CO40

Dimensions are in millimeters.

Centre Support Octagonal Umbrella Model:SUA-CO40 Engineering Framing

=

==

Plan

230 embedment (cast in)

Natural ground 4-N16 vertical R6 helix at 300 pitch

40 min 120 max

150

300

Non-shrink grout

4-M12 Gr.4.6/S galvanised H.D. bolts with nuts and levelling nuts - Cog 100 Bolt projection to suit level of top of paving, tiling, etc 40 min 120 max.

1400

140

grout

430 min overlap

=

==

140

Plan Non-shrink

==

900

=

140

==

Assumed soil conditions: Pad - bearing capacity 100kPa Pier - cu=50kPa (stiff clay)

60 cover

=

Notes: Design wind speed 33m/sec (W33)

140

900

Minimum 60mm cover to all reinforcement Concrete grade to be N25 20mm aggregate size Slump 65mm Anchor bolt location tolerances per Australian Standard AS 4100-1990 - 3mm for anchor bolt centres within an anchor bolt group. - 6mm for adjacent anchor bolt group centres. - Maximum accumulation of 6mm per 30m not to exceed a total of 25mm. - 6mm from anchor bolt group centre to column line centre.

F82 fabric central

Bolt projection 40 min. 120 max. Embedment 110 min.

2025

eral l

4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. Supplied with nuts, washers and levelling nuts. Chemical anchors, at 140 x 140 centres to be 'Hilti HVU', or engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions. Hole to be clean and dry at time of installation.

Elevation

SUA-CO40 Pier Footing 2025

4050 overall

140 c/crs

Ø450

2025

Non-shrink grout

0 ov

SUA-CO40 Pad Footing

Natural Ground

437

Elevation

2025

4050 overall

H.D. Bolt Layout Plan

Chemical Anchor Detail

Not to scale

Centre Support Octagonal Umbrella Model:SUA-CO40 Footing Detail

140 c/crs

* H.D. BOLT NOTE Structure pole has 200 x 200 x 12 base plate. 4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. at 140 x 140 centres.

140 c/crs

120 max

See Bolt* and Slab Note*

Pavers/Tiles Non-shrink grout

Embedment Refer Table

Grout/bedding (no sand)

varies

Pavers/Tiles

Slab Thickness Refer Table

varies

Non-shrink grout

Embedment Refer Table

Slab Thickness Refer Table

120 max.

Levelling nuts

Levelling nuts

Over Pavers 120 max

140 c/crs

See Bolt* and Slab Note*

* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint. Contact a SUA Dealer if the slab does not meet any of the requirements.

Under Pavers

Chemical Anchor Fixing to Slab on Ground

On Slab Slab Thickness 100 110 120 130 140 plus

Min. Embedment H.D. Bolts* Chemical Anchor Min. Slab Edge Distance* 80 4-M12 at 140 c/crs 400 Ramset Reo 502 (or Hilti HIT-RE 500) 90 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 100 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 110 400 Hilti HVU 4-M12 at 140 c/crs 110 400 Hilti HVU 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions.

Installation Detail Model SUA-CO40

2025

2025

4050 overall

H.D. Bolt Layout Plan

Not to scale

Centre Support Octagonal Umbrella Model:SUA-CO40 Installation Detail

4050 overall

2025 2025

See Bolt* and Slab Note*

437 0 ov eral l

Levelling nuts

Embedment Refer Table

Slab Thickness Refer Table

Non-shrink grout

Varies 120 max.

Slab Thickness Refer Table Embedment Refer Table

Pavers/Tiles

Over Pavers

Slab Thickness Refer Table Embedment Refer Table

140 c/crs

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws. (Counter-sunk option if required)

* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint.

Non-shrink grout See Ferrule* and Slab Note*

Contact SUA Dealer if the slab does not meet any of the requirements.

At Pavers Rubber grommets, stainless steel grub screws with hex socket or brass flat dome head screws, screwd into ferrule flush with paving to keep ferrule thread clean.

437

2025

0 ov

See Ferrule* and Slab Note*

Flexible sealant (Mastic or similar) Pavers/Tiles

Slab Thickness Refer Table Embedment Refer Table

Grout/bedding (no sand) See Ferrule* and Slab Note*

140 c/crs

* FERRULE NOTE Ferrules at 140 x 140 centres are M20 stainless steel Gr.316 threaded rods tapped for M12.

Chemical Anchor Fixing to Slab on Ground Slab Thickness 100 110 120 130 140 plus

Ferrule Fixing with Umbrella Removed

2025

On Slab

Ferrules* Min. Embedment Min. Slab Edge Distance* Chemical Anchor 80 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 90 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 100 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 110 400 4-M12 at 140 c/crs Hilti HVU 110 400 Hilti HVU 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions.

Ferrule Detail Model SUA-CO40

2025

2025

4050 overall

H.D. Bolt Layout Plan

Not to scale

Centre Support Octagonal Umbrella Model:SUA-CO40 Ferrule Fixing

4050 overall

Varies 120 max.

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws.

Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 counter-sunk set screws.

eral l

3 mm clearance

140 c/crs