Pavers/Tiles. Non-shrink grout. Levelling nuts. See Bolt* and. Slab Note*. Non-shrink grout. Levelling nuts. See Bolt* a
300
TOP HAT aluminium powder coat finish
Stainless steel sleeve pole protector for length of collar travel.
Collar and arm in closed position.
4950 overall
4350 minimum
534 5 ov
eral l
FABRIC, PVC PVDF coated Standard colour, white
Plan
1:100 at A4
CABLE S.S. Gr.316 with S.S. fittings
NOTE: Allow up to 50mm sag due to stretch of membrane fabric.
ARM Ø38 CHS powder coat finish
Arc of arm when opening.
COLLAR Ø102 CHS powder coat finish (in opened position)
1:100 at A4
OCTAGONAL 5m - SUA-CO50 Wind Rating: 33m/sec (120km/h) Rated when umbrella is fully erected. Umbrella weight: 96kg Overall dimensions represent clearance dimensions for the complete umbrella. Membrane dimensions differ, depending on variations in tensioning and fabrication.
OPENED POSITION
1235
500
1000
1500
2000
1910 2200
860
0
650
BASE PLATE 200x200x12 pl. with Ø50 service hole. 4-M12 hold down bolts at 140mm c/crs. Grade 4.6/s galvanised or stainless steel Gr.316. With dome nuts and levelling nuts.
545
POLE Ø89 CHS powder coat finish
550
Elevation
3360
2200 clear
RETAINING ROD stainless steel
2500 2630
CLOSED POSITION
5m Centre Support Octagonal Umbrella Model SUA-CO50
Dimensions are in millimeters.
Centre Support Octagonal Umbrella Model:SUA-CO50 Engineering Framing
=
==
Plan
230 embedment (cast in)
40 min 120 max
Anchor bolt location tolerances per Australian Standard AS 4100-1990 - 3mm for anchor bolt centres within an anchor bolt group. - 6mm for adjacent anchor bolt group centres. - Maximum accumulation of 6mm per 30m not to exceed a total of 25mm. - 6mm from anchor bolt group centre to column line centre.
Natural ground 4-N16 vertical R6 helix at 300 pitch
150
300
Non-shrink grout
4-M12 Gr.4.6/S galvanised H.D. bolts with nuts and levelling nuts - Cog 100 Bolt projection to suit level of top of paving, tiling, etc 40 min 120 max.
1400
140
grout
Minimum 60mm cover to all reinforcement Concrete grade to be N25 20mm aggregate size Slump 65mm
Bolt projection 40 min. 120 max. Embedment 110 min.
4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. Supplied with nuts, washers and levelling nuts. Chemical anchors, at 140 x 140 centres to be 'Hilti HVU', or engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions. Hole to be clean and dry at time of installation.
2475 4950 overall
Non-shrink grout
Ø450
Elevation
SUA-CO50 - Pier Footing
2475
SUA-CO50 Pad Footing
534 5 ov eral l
Natural Ground
2475
2475 4950 overall
H.D. Bolt Layout Plan
Chemical Anchor Detail
Not to scale
Centre Support Octagonal Umbrella Model:SUA-CO50 Footing Detail
140 c/crs
* H.D. BOLT NOTE Structure pole has 200 x 200 x 12 base plate. 4-M12 H.D. bolts to be threaded rod grade 4.6/s hot dipped galvanised, or stainless steel Gr.316. at 140 x 140 centres.
140 c/crs
120 max
See Bolt* and Slab Note*
Pavers/Tiles Non-shrink grout
Embedment Refer Table
Grout/bedding (no sand)
varies
Pavers/Tiles
Slab Thickness Refer Table
varies
Non-shrink grout
Embedment Refer Table
Slab Thickness Refer Table
120 max.
Levelling nuts
Levelling nuts
Over Pavers 120 max
140 c/crs
See Bolt* and Slab Note*
* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint. Contact a SUA Dealer if the slab does not meet any of the requirements.
Under Pavers
Chemical Anchor Fixing to Slab on Ground
4950 overall
2475 2475
See Bolt* and Slab Note*
534 5 ov eral l
Levelling nuts
Embedment Refer Table
Slab Thickness Refer Table
Non-shrink grout
On Slab Slab Thickness 100 110 120 130 140 plus
Min. Embedment H.D. Bolts* Chemical Anchor Min. Slab Edge Distance* 80 4-M12 at 140 c/crs 400 Ramset Reo 502 (or Hilti HIT-RE 500) 90 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 100 400 4-M12 at 140 c/crs Ramset Reo 502 (or Hilti HIT-RE 500) 110 400 Hilti HVU 4-M12 at 140 c/crs 110 400 Hilti HVU 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions.
Installation Detail Model SUA-CO50
2475
2475 4950 overall
H.D. Bolt Layout Plan
Not to scale
Centre Support Octagonal Umbrella Model:SUA-CO50 Existing Slab on Ground
Varies 120 max.
Over Pavers
Slab Thickness Refer Table Embedment Refer Table
140 c/crs
Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws. (Counter-sunk option if required) See Ferrule* and Slab Note*
See Ferrule* and Slab Note*
Contact a SUA Dealer If the slab does not meet any of the requirements.
At Pavers Rubber grommets, stainless steel grub screws with hex socket or brass flat dome head screws, screwd into ferrule flush with paving to keep ferrule thread clean.
On Slab
Chemical Anchor Fixing to Slab on Ground Slab Thickness 100 110 120 130 140 plus
Non-shrink grout
Ferrule Fixing with Umbrella Removed
Min. Embedment 80 90 100 110 110
Ferrules* Min. Slab Edge Distance* 4-M12 at 140 c/crs 400 400 4-M12 at 140 c/crs 400 4-M12 at 140 c/crs 400 4-M12 at 140 c/crs 400 4-M12 at 140 c/crs Chemical anchor to be as above or Engineer approved equivalent, and to be installed in accordance with the manufacturer's instructions. Chemical Anchor Ramset Reo 502 (or Hilti HIT-RE 500) Ramset Reo 502 (or Hilti HIT-RE 500) Ramset Reo 502 (or Hilti HIT-RE 500) Hilti HVU Hilti HVU
Ferrule Detail Model SUA-CO50
4950 overall
See Ferrule* and Slab Note*
* SLAB ON GROUND NOTE The existing reinforced concrete slab on ground is to be approved for adequacy by a Structural Engineer before installation. Concrete strength - f'c 25MPa. Installation requires 1 sq m of continuous reinforced slab with the pole centre 400mm minimum from a slab edge or control joint.
Pavers/Tiles
Slab Thickness Refer Table Embedment Refer Table
Grout/bedding (no sand)
Flexible sealant (Mastic or similar)
2475
Slab Thickness Refer Table Embedment Refer Table
Pavers/Tiles
140 c/crs
* FERRULE NOTE Ferrules at 140 x 140 centres are M20 stainless steel Gr.316 threaded rods tapped for M12.
2475
Varies 120 max.
Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 set screws.
Structure pole with 200 x 200 x 12 base plate. 4-M12 S.S. Gr.316 counter-sunk set screws.
534 5 ov eral l
3 mm clearance
140 c/crs
2475
2475 4950 overall
H.D. Bolt Layout Plan
Not to scale
Centre Support Octagonal Umbrella Model:SUA-CO50 Ferrule Fixing