Carrier Comfort Network (CCN) makes them possible! What if you can ... Monitors performance based on real time chiller p
Carrier Hong Kong Limited
Carrier Comfort Network - optimizes the performance of HVAC Systems & is the premier solution for Building Control
Carrier Comfort Network
Fire Systems
Lifts & Elevators
Plumping Systems
Major components in Building Management System CCTV Systems
Lighting Systems
Security Systems
Temperature Controls
HVAC Systems
Opportunities for better efficiency, comfort, remote control & analytical analytical capability. Experience the difference! What if you can improve system performance & extend the equipment life? How better the case will be if you can manage your chilled water plant for greater comfort & efficiency? What if you can coordinate up to eight centrifugal, screw or reciprocating chillers? Orchestrate all peripherals? Integrate with your building's entire HVAC system? Trim down energy cost?
Carrier Comfort Network (CCN) makes them possible!
Efficiency Provides stable operation by scheduling, chilled water set-point reset, etc Replaces manual tasks by automatic control
Comfort Provides a balanced temperature, relative humidity & fresh air environment
Analytical Capability Remote Control
02
Enables two way remote access to the systems for control diagnosis
Captures data for energy analysis
Comfort Controller Hardwire
19XR Centrifugal Chiller Chillervisor System Manager
Cooling Tower
Cooling Tower Control
[ Chillervisor System Manager (CSM III) ] Hardwire
Condensing Water Pump Control
Condensing Water Pump
CCN Bus Chilled Water Pump Control
Central control & management of multichillers Auto start & stop chillers to balance operating hours Enhances working efficiency of chillers
Hardwire Chilled Pump
Water
30GX/HX Screw Chiller
[ Universal Controller and Comfort ID ]
[ Comfort View ]
Applies to control Air Handler Units, Fan Coil Units and VAV zoning systems
Illustrational operation allows immense convenience on Building Management System
VAV zoning
Air Handler Unit
Comfort ID Universal controller
[ CCN Web ]
[ Prognostics Services ]
Navigates the whole CCN by using internet anywhere and anytime
Monitors performance based on real time chiller performance parameters CCN Prognostics monitor
Local ISP dial-in internet
Schedule actions upon receipt of indications Web Browsers
Remote service technicians or any PC with modem
03
Carrier Comfort Network
Chiller System Manager ties up multiple stand-alone equipment together for an automated chiller plant to increase efficiencies and reduces operational costs. Chillers under control can be centrifugal, reciprocating, screw…….in the same plant.
CMS III offers… offers….
Performance Performance
Paybacks Paybacks
Stable water chilling plant temperature control Automatic restoration of plant capacity after power failure Equalizes chiller operating hours by automatically rotating chillers Minimizes the downtime of the chiller plant
Expandability
Reliability Reliability
Factory Proven Control Logic & Programming Fills in the Blank & Selection Control Logic for application
04
Optimizes equipment start/stop to reduce electricity demand charge Temperature reset for energy savings Demand limits to meet customers’ expectation on energy consumption
No programming is required for adding new chillers
Ease of Installation Ease of Installation
Main chiller supply temperature sensor & main chiller return temperature sensor are required for most of application
Low Investment Cost Low Investment Cost
Low Running Cost Low Running Cost
Less engineering time
Optimizes chiller operation before starting lag chiller
[ Pre-engineered Standard Control Algorithm ]:
Lighting
Pump
Exhaust fan
Heating/cooling coil control Humidification/dehumidification Mixed air damper optimization VAV fan control VAV supply & return fan tracking Indoor Air Quality for CO2 sensor control Generic PID control Control point reset Time of day scheduling Discrete device controlled as analog Discrete staging Thermostat simulation
Boiler
[ Features & Functions ]:
Heating/cooling coil control Stand-alone DDC control Pre-engineered standard control algorithms Energy saving/optimization routines On-board data trending On-board consumable 365-day real-time clock with holidays No battery is necessary for holding programs and parameters Variable Air Volume Systems Pressure Independent DDC VAV air terminal controller VAV Cooling, Parallel and Series Fan Box Terminals CV & VAV Dual Duct Terminals Zone Pressure Control Demand Control Ventilation for IAQ
05
Carrier Comfort Network
Displays dynamic data in both test and graphic modes Creates dynamic trend plots of data from one or multiple controllers Adjusts operating parameters such as time schedules, set points and point configuration Customizes graphics and create custom links Generates reports from system data
CCNWeb is a cost-effective method to achieve Internet connectivity to Carrier's communicating controls by eliminating the need for an on-site computer. It includes a library of ViewSPACE templates for most CCN controllers.
Setpoint
Time schedule
Cell phone Web access to CCN
Graphic display
PDA
Alarm
Status display
Desktop
- predictive intelligence What if you could predict and prevent chiller failures? What if you could be immediately alerted to equipment performance issues, enabling you to resolve them before they affected operating efficiency?
Carrier's Prognostics Service makes this possible!
[ Historical Data ]
[ Reliability ]
24-hour data collection for analysis
Provides reliable operation by predictive ability Enables equipment to be repaired before it shuts down
[ Performance ] Prognostics:
Learning:
06
Normal Operation Normal Operation
Prognostic Thresholds
Chiller Failure Metric
Chiller Failure Metric Time
Prognostic Alarm
Time
Advanced Warning
BACnet/Modbus Translator
Data Transfer Option
Application Supplies BACnet MS/TP or Modbus RS485 One Translator for each piece of equipment Supports any controller that speaks CCN Auto-finds PIC Auto-maps First 60 Points Can be changed View, Force/Auto status point data Allows Time/Setpoint BACnet MS/TP Schedule adjustments or Modbus
Data Collection IV/Data Transfer Option (DCIV)
Eprom Memory – no batteries required Communication rate up to 38400 baud Daily, monthly, and yearly reports for Runtimes and Consumables 99 Data collection tables History - analog or discrete points (temperature, humidity, fan, etc.) Runtimes - discrete points only (fan/pump status) 1 table supports 8 points Consumable - analog or pulse meter point (KW, flow, etc.)
Chiller Interface CSMIII interface for 3rd party chillers or Carrier chillers without PICs Centrifugal, Screw, Scroll, Rotary, reciprocating and absorption chillers Carrier & non-Carrier brands Must meet I/O requirements Occupancy Schedule for backup local mode Chilled water reset (4-20mA/0-10Vdc) Demand Limit (4-20mA/0-10Vdc)
LON Translator Application Supplies LON FT-10A ANSI/EIA709.1 3 Profiles Chiller Rooftop Generic One Translator for each piece of equipment Supports any controller that speaks CCN Auto-finds PIC View, Force/Auto status point data Allows Time/Setpoint Schedule adjustments 07
Carrier Comfort Network
Baptist University Educational Resource Centre French International School HKUST VTC
Institutions
Lee Yue Mun Plaza Ming Tak Shopping complex Wing On Centre Whampoa Garden
Shopping Complex
Bank of China Public Bank Centre Shanghai Commercial Bank
Banks
Gate Gourmet Catering Facility Garment Centre Hua Wei Technologies Factory SCMP Factory
Industrial Buildings
Commercial Buildings
DHL Centre Equinix Hong Kong Limited Exchange Square III Science Park St. George’s Building Disneyland Hotel Hollywood Hotel Wharney Guang Dong Hotel
Hotels
Macau International Airport HK Productivity Centre MTRC
Others
For more detailed information on CCN, please feel free to contact us. E-mail Website 08
: :