Heating. Nom. m³/min. 48.0. 83. Sound power level Cooling. dBA. 65. 70. 71. 70. 71. Sound pressure level. Cooling. Nom.
Siesta

Sky Air COMMERCIAL CATALOGUE

About

Daikin

Daikin has a worldwide reputation based on over

90 years’ experience in the successful manufacture of high quality heating, ventilation, air conditioning and refrigeration equipment for industrial, commercial and residential use and 55 years as leader in heat pump technology.

2

Daikin quality Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.

Environmental awareness Air conditioning enhances the indoor climate, providing pleasant

the market. Similarly, advanced computerised control packages

working and living conditions in even the harshest climates.

ensure optimum system efficiency at all times and allow remote

In recent years however, aware of the need to safeguard

monitoring via the internet.

the environment, Daikin has taken great strides to limit

Reducing waste

negative effects associated with its production and operation.

Daikin was the first European air conditioning manufacturer to

As a result, new energy saving equipment combined with

gain ISO14001 environmental certification. The company’s zero

innovative manufacturing techniques, minimise any impact on

waste policy ensures that many of its manufacturing by products

the environment.

can be recycled, reused or recovered.

Commitment to the environment

Recycling materials

Concern for the environment is inherent throughout Daikin’s

Daikin recycles materials as a matter of course. For instance,

global operations, from design and production to the everyday

the sludge recovered from pre treated waste water is used in

actions of its workforce. Daikin heat pumps in combination with

cement manufacture. The recycling of other types of waste is also

in-house inverter technology offer unparallelled indoor heating

supported by investment in returnable packaging.

comfort and process efficiency.

Daikin leading the way to seasonal efficiency

Heat pump efficiency

Seasonal efficiency is a measure mandated by the European

Heat pumps can extract heat energy from the outside air, even on

Union to optimise energy consumption. The EU wants to make

the coldest days of winter. Daikin systems are capable of providing

people aware of what units are consuming and ban non-efficient

comfortable and efficient indoor heating as well as meeting exact

products from the market. Seasonal efficient units reflect the

industrial heating and cooling requirements.

actual performance you can expect over an entire heating and

Energy efficient equipment

cooling season. The standard came into force in January 2013 for

Many product innovations stem from Daikin environmental

products under 12kW.

awareness. Inverter control reduces unit start up time and varies

Today, Daikin is leading the way towards more efficient and cost-

compressor output to match precise system load requirements.

effective comfort solutions. All Daikin products - residential and

Also, when linked with Daikin DC compressor motors, it allows

commercial as well as industrial - are seasonal efficient, they all

Daikin equipment to achieve the highest COP ratings in

reduce energy and costs in a smart way.

3

Why choose Daikin? Cutting edge technology For the last 50 years, Daikin has been the market leader in cutting-edge climate control technology that is both energy efficient and eco-friendly. Our systems have been independently tested against the latest and most demanding energy and ecological standards and our heat pump systems were the first to receive the EU’s Eco-Label.

3/4 Renewable

ambient air

As your partner of choice for the installation and maintenance of flexible, trouble-free and costeffective climate control solutions, we have a global network of engineers providing local

ser vice . B y installing Daikin equipment you can be assured that you have very energy efficient units with a low ecological impact thus saving you money and helping the environment.

Heat pump Air-to-air heat pumps obtain 75% of their output energy from a renewable source: the ambient air, which is both renewable and inexhaustible*.

1/4 Electrical energy

Of course, heat pumps also require electricity to run the system, but increasingly this electricity can also be generated from renewable energy sources such as solar energy, wind energy, hydropower and biomass. A heat pump’s efficiency is measured in COP (Coefficient Of Performance) for heating and EER (Energy Efficiency Ratio) for cooling. * EU objective COM (2008)/30

Heat pump system:

compared to

COP 3.61*

Traditional electrical heating system: COP

3/4 kW 3/4 kW + + 3/4 kW 1/4 kW 4/4 kW1/4 kW+ 1 600mm

1

Radiateur standard basse température

0.75 kW

renewable energy (air)

+

3/4 kW +1 kW energy

0.25 kW

1/4 kW

1/4 kW 700mm 4

2000mm

4/4 kW 4/4 kW 600mm

4/4 1 kW Console Daikin

Desired room temperature optimally maintained

22°C

Inverter technology Daikin’s inverter technology is a true innovation in the field of climate control. The principle is simple: inverters adjust the power used to suit the actual requirement - no more, no less! This technology provides you with two main benefits:

1. Optimizing comfort levels The inverter repays its investment many times over by improving comfort. A climate control system with an inverter continuously adjusts its cooling and heating output to suit the temperature in the room, thus improving comfort levels. The inverter reduces system start-up time enabling the required room temperature to be reached more quickly. As soon as the correct

Temperature / Power input

temperature is reached, the inverter ensures that it is

Air conditioning without Inverter

constantly maintained.

Slow start

2. Energy efficiency

Set temp.

Because an inverter monitors and adjusts ambient temperature whenever needed, energy consumpTemperature remains stable

Air conditioning with Inverter

tion drops by 30% compared to a traditional on/off Time

5

(non-inverter) heat pump system!

Overview Indoor units Type

Model Siesta, 4-way blow ceiling mounted cassette

Ceiling mounted cassette

ACQ-C

• for shops requiring maximum floor space and perfect integration • solution for basic cooling and heating

Siesta, concealed ceiling unit

Concealed ceiling

ABQ-C

• for shops requiring maximum floor space and perfect integration • solution for basic cooling and heating

Siesta, ceiling suspended cassette

Ceiling suspended

System

AHQ-C

• for shops with narrow or no false ceiling • solution for basic cooling and heating

Outdoor units

Pair application

Type

Product name AZQS-BV1

• for shop application • basic cooling/heating solution • pair application

AZQS-BY1

Seasonal efficiency gives a more realistic indication on how efficient air conditioners operate over an entire heating or cooling season.

Inverter technology

In combination with inverter controlled outdoor units

Fan only

The air conditioner can be used as fan, blowing air without cooling or heating.

Draught prevention

When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.

Auto cooling-heating changeover

Automatically selects cooling or heating mode to achieve the set temperature.

Air filter

Removes airborne dust particles to ensure a steady supply of clean air.

Ceiling soiling prevention

A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.

Fan speed steps

Allows to select up to the given number of fan speed.

Weekly timer

Timer can be set to start operation anytime on a daily or weekly basis

Infrared remote control

Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance.

Wired remote control

Wired remote control to start, stop and regulate the air conditioner from a distance.

Auto-restart

The unit restarts automatically at the original settings after power failure.

Self-diagnosis

Simplifies maintenance by indicating system faults or operating anomalies.

Drain pump kit

Facilitates condensation draining from the indoor unit.

Air flow

Air treatment

Comfort

We care icons

Seasonal efficiency - Smart use of energy

Remote control & timer

Heat pump

Model

Other funtions

Air cooled

Product name

INVERTER

6

Capacity (class)

25

35

50

60

71

100

125

140

200

250

Capacity (class)

71

100

125

140

200

250

Ceiling mounted cassette

Concealed ceiling unit

Ceiling suspended unit

ACQ-C

ABQ-C

AHQ-C































4

3

3











standard

standard

optional

standard

optional













standard

7

ACQ-C / AZQS-BV1/BY1

ACQ71C

›› ›› ›› ›› ›› ›› ››

Siesta, 4-way blow ceiling mounted cassette

AZQS71BV1

ARCWLA

Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings Air can be discharged in any of 4 directions Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance Control several indoor units at the same time via the Siesta Sky Air group control (optional) Standard drain pump Fresh air intake: up to 20 %

Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input Seasonal efficiency (according to EN14825)

Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Dimensions Weight Decoration panel

Fan - Air flow rate Sound power level Sound pressure level Piping connections Power supply

Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Cooling Energy label Pdesign SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption EER COP Annual energy consumption Energy label Cooling/Heating HeightxWidthxDepth Unit Unit Colour HeightxWidthxDepth Dimensions Weight High/Nom./Low/Silent operation Cooling High/Nom./Low/Silent operation Heating Cooling Heating High/Nom./Low/Silent operation Cooling High/Nom./Low/Silent operation Heating Liquid OD Gas OD Phase / Frequency / Voltage

OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections

Power supply Current - 50Hz

kW kW kW kW

ACQ71C -/6.8/-/7.50/2.05 2.08

kW

6.80

ACQ71C -/6.8/-/7.50/2.05 2.08

9.50

3.01 3.41 2,010 B/B

6.80

kWh

512

716 A

kW

6.33

7.60 3.80

kWh

2,332 3.31

kWh

1,025 B/A 265x820x820 31

2,800 3.21 3.61

mm kg mm kg m³/min m³/min dBA dBA dBA dBA mm mm Hz / V

m m m m Hz / V A

24.4/20.5/17.6/15.0 24.4/20.5/17.6/15.0 54 54 41/38/35/32 41/38/35/32

AZQS71BV1 770x900x320 67 52.0 48.0 65 48/43 50 -

ACQ100C -/9.5/-/10.8/2.96 2.99

ACQ125C -/12.1/-/13.5/4.02 3.96

9.50

3.01 3.41 2,010 B/B

B

4.65

mm kg Nom. m³/min Nom. m³/min dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB

(1) EER/COP according to Eurovent 2012, for use outside EU only

ACQ125C -/12.1/-/13.5/4.02 3.96

B

HeightxWidthxDepth

OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)

ACQ100C -/9.5/-/10.80/2.96 2.99

1,480 A/A

4.65 512 6.33

7.60 3.80

2,332 3.31

2,800 3.21 3.61

1,025 B/A 265x820x820 31

300x820x820 39

29.2/24.4/21.0/17.6 29.2/24.4/21.0/17.6 57 56 44/41/38/36 44/41/38/36

716 A

White 82x990x990 4 34.0/29.2/26.3/22.1 24.4/20.5/17.6/15.0 34.0/29.2/26.3/22.1 24.4/20.5/17.6/15.0 60 54 60 54 47/44/43/41 41/38/35/32 47/44/43/41 41/38/35/32 9.52 15.88 1~ / 50 / 220-240

AZQS100BV1

1,480 A/A 300x820x820 39

29.2/24.4/21.0/17.6 29.2/24.4/21.0/17.6 57 56 44/41/38/36 44/41/38/36

AZQS125BV1 AZQS100BY1 990x940x320 81

76

34.0/29.2/26.3/22.1 34.0/29.2/26.3/22.1 60 60 47/44/43/41 47/44/43/41

AZQS125BY1 82

77

76

77

70 53/57

71 54/58

83 70 53/57

71 54/58 49 -5~46 -15~15.5 R-410A/1,975

30 40 15.0 -

50 70 30.0 0.5 1~ / 50 / 220-240

20

3N~ / 50 / 380-415 -

ABQ-C / AZQS-BV1/BY1

ABQ71C

›› ›› ›› ›› ››

Siesta, concealed ceiling unit

AZQS71BV1

ARCW8 (standard)

Ideal solution for shops, requiring maximum floor space for furniture, decorations and fittings Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Air filter removes airborne dust particles to ensure a steady supply of clean air Easy installation and maintenance Double-protection drainage system: primary and secondary drain pan

Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input

Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Nom./Low Heating High/Nom./Low Fan - External static pressure High/Nom./Low Sound power level Cooling Heating Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Piping Liquid OD connections Gas OD Power supply Phase / Frequency / Voltage OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Heating Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections

Power supply Current - 50Hz

kW kW kW kW

ABQ71C 6.8 -/7.5/2.33 2.13

kW

6.80

kWh

512

ABQ125C 12.1 -/13.5/4.31 3.96

ABQ140C -/13.0/-/15.5/4.32 4.55

B

715 A

kW

5.65

6.78 3.80

kWh

kWh mm kg m³/min m³/min Pa dBA dBA dBA dBA mm mm Hz / V

mm kg Nom. m³/min Nom. m³/min dBA dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB m m m m Hz / V A

2,082 2.91 3.51 1,165 C/B 285x600x1,007 35 18.3/16.8/15.4 18.3/16.8/15.4 90/77/64 64 64 -

AZQS71BV1 770x900x320 67 52.0 48.0 65

2,498 2.62 3.42 1,813 D/B 378x541x1,045 44 22.7/20.5/18.3 22.7/20.5/18.3 70/57/45 60 60 41/38/36 41/38/36

ABQ100C -/9.5/-/10.8/3.63 3.16 B 9.50 4.65 624 A 6.78 3.80 3,500 2.62 3.42 1,813 D/B 378x541x1,045 44 22.7/20.5/18.3 22.7/20.5/18.3 70/57/45 60 60 41/38/36 41/38/36

-

9.50 4.65

HeightxWidthxDepth

OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)

ABQ100C 9.5 -/10.8/3.63 3.16

2.81

3.01 3.41

2,153 C/B 378x541x1,299 50 40.5/37.4/34.8 40.5/37.4/34.8 150/128/111

2,159 378x541x1,499 56 48.7/43.9/37.9 48.7/43.9/37.9 150/122/92 -

53/52/50 53/52/50

AZQS100BV1 AZQS125BV1 990x940x320 81 76 77 83 70 71

55/53/50 55/53/50 9.52 15.88 1~ / 50 / 220-240 AZQS140BV1 1,430x940x320 102 83 62

ABQ125C -/12.1/-/13.5/4.31 3.96

ABQ140C -/13.0/-/15.5/4.32 4.55 -

2.81

3.01 3.41

2,153 C/B 378x541x1,299 50 40.5/37.4/34.8 40.5/37.4/34.8 150/128/111

2,159 378x541x1,499 56 48.7/43.9/37.9 48.7/43.9/37.9 150/122/92 -

53/52/50 53/52/50

AZQS100BY1 AZQS125BY1 990x940x320 82 76 77 83 70 71

55/53/50 55/53/50

AZQS140BY1 1,430x940x320 101 83 62 70

48/43 50 -

53/57

54/58

53/54

57

54/58

49 -5~46 -15~15.5 R-410A/1,975

30 40 15.0 -

50 70 30.0 0.5 1~ / 50 / 220-240

20

3N~ / 50 / 380-415 -

(1) EER/COP according to Eurovent 2012, for use outside EU only

9

53/54

AHQ-C / AZQS-BV1/BY1

AHQ125CV1

›› ›› ›› ›› ››

Siesta, ceiling suspended unit

AZQS140BV1/BY1

ARCWLA

Ideal solution for commercial spaces with no or narrow false ceilings Can be installed in both new and existing buildings Air filter removes airborne dust particles to ensure a steady supply of clean air Decrease of temperature variation by automatic fan speed selection or freely selectable 3-step fan speed. Easy installation and maintenance

Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Power input

Min./Nom./Max. Min./Nom./Max. Cooling Nom. Heating Nom. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan - Air flow rate Cooling High/Nom./Low Heating High/Nom./Low Fan - External static pressure High/Nom./Low Sound power level Cooling Heating Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Piping Liquid OD connections Gas OD Power supply Phase / Frequency / Voltage OUTDOOR UNIT Dimensions Unit Weight Unit Fan - Air flow rate Cooling Heating Sound power level Cooling Sound pressure Cooling level Heating Night quiet mode Operation range Cooling Heating Refrigerant Type/GWP Piping Piping length connections

Power supply Current - 50Hz

kW kW kW kW

AHQ100C -/9.5/-/10.8/3.62 3.17

AHQ125C -/12.1/-/13.5/4.60 3.74

B kW kWh

6.80 4.65 511

kW

6.33

7.60 3.80

kWh

kWh

mm kg m³/min m³/min Pa dBA dBA dBA dBA mm mm Hz / V

mm kg Nom. m³/min Nom. m³/min dBA Nom./Silent operation dBA Nom. dBA Level 1 dBA Ambient Min.~Max. °CDB Ambient Min.~Max. °CWB m m m m Hz / V A

2,332 3.03 3.05 1,120 B/D

2,800 2.62 3.41 1,810 D/B

2.63 3.61 2,300 D/A

260x1,320x634 38 23.8/21.3/18.9 23.8/21.3/18.9

260x1,538x634 45 31.1/27.8/24.8 31.1/27.8/24.8

260x1,786x634 54 34.4/30.6/27.2 34.4/30.6/27.2

59 62 49/48/46 49/48/46

64 64 52/47/46 52/47/46

69 69 52/50/49 52/50/49

AZQS71BV1 770x900x320 67 52.0 48.0 65 48/43 50 -

AHQ140C -/13.0/-/15.5/4.32 4.55

AHQ100C -/9.5/-/10.8/3.62 3.17 B 9.50 4.60 723 A 7.60 3.80 2,800 2.62

-

9.50 4.60 723 A

HeightxWidthxDepth

OU - IU Max. System Equivalent Level difference IU - OU Max. IU - IU Max. Phase / Frequency / Voltage Maximum fuse amps (MFA)

AHQ71C -/6.8/-/7.5/2.24 2.46

AZQS100BV1 AZQS125BV1 990x940x320 81 76 77 83 70 71 53/54/57 58

3.01

AHQ140C -/13.0/-/15.5/4.32 4.55 -

1,810 D/B

2.63 3.61 2,300 D/A

3.01 3.41 2,159 B/B

260x1,538x634 45 31.1/27.8/24.8 31.1/27.8/24.8

260x1,786x634 54 34.4/30.6/27.2 34.4/30.6/27.2

285x1,902x680 70 43.9/39.1/28.3 43.9/39.1/28.3

64 64 52/47/46 52/47/46

69 69 52/50/49 52/50/49

70 70 56/53/46 56/53/46

3.41 2,159 B/B White 285x1,902x680 70 43.9/39.1/28.3 43.9/39.1/28.3 0/0/0 70 70 56/53/46 56/53/46 9.52 15.88 1~ / 50 / 220-240

AHQ125C -/12.1/-/13.5/4.60 3.74

AZQS140BV1 1,430x940x320 102 83 62

54

AZQS100BY1 AZQS125BY1 990x940x320 82 76 77 83 70 71 53/54/57 58 49

-5~46 -15~15.5 R-410A/1,975 30 40 15.0 -

50 70 30.0 0.5 1~ / 50 / 220-240

20

3N~ / 50 / 380-415 -

(1) EER/COP according to Eurovent 2012, for use outside EU only

10

AZQS140BY1 1,430x940x320 101 83 62 70 53/54

ARCWLA / ARCWB

Siesta individual control systems

Overview controllers for Siesta Sky Air SIESTA SKY AIR INDOOR UNITS

CONTROLLERS

ACQ-C 4-way blow, ceiling mounted cassette

- Standard infrared remote control (ARCWLA) in box of decoration panel ADP125A - Optional wired remote control ARCWLB - Optional group controller R04084124324

AHQ-C ceiling suspended

- Standard infrared remote control in box of indoor unit ARCWLA - Optional wired remote control ARCWB - Optional group controller R04084124324

ABQ-C concealed ceiling

- Standard wired remote control (ARCWB) in box of indoor unit - Optional group controller R04084124324

Overview of features FEATURE

ARCWB Option for AHQ-C and ACQ-C Standard for ABQ-C

1

ON/OFF switch

Standard Default range 16-30°C

Standard

Optional range 20-30°C

By dipswitch selection

2

Temperature setting

3

Room temperature sensor on remote control

Switch between °C and °F

Standard Standard

4

Cool / Fan dry / Heat / Auto

Standard

5

Sleep mode

Standard

6

Fan Speed selection

7

Delay timer

Standard 1, 2 & 4 hours delay

8

7-days programmable timer

Standard

9

Real time clock display

Standard

10

Air swing selection

11

LCD display without backlight

Standard

12

Key lock

Standard

13

Error code indication

Standard

14

IR receiver to enable compatibility with infrared remote control (disabled when lock function is activated)

Standard

15

Last state memory from indoor PCB

16

Silent mode

By dipswitch selection

17

Turbo mode

By dipswitch selection

18

Compressor test model (compressor force ON)

Standard

19

Daikin inverter error code

Standard

20

UART communication port (for Daikin protocol)

Standard

21

Backup battery

Standard

ON/OFF swing mode

Standard

Change swing option (draft/soil prevention or standard)

Standard

Standard

Specifications Dimensions (length x width x height) ARCWB: 0.15 m x 0.21 m x 0.04 m. ARCWB comes standard with a 10 meter wire, which can be extended to maximum wire length of 15 meter. ARCWB can only control one indoor unit at a time; group control is only possible when using option R04084124324. 11

Europe’s new energy label: raising the bar on energy efficiency To realise its challenging 20-20-20 environmental goals, Europe is imposing minimum efficiency requirements for energy related projects. These minimum requirements came into effect on 1 January 2013, and will be revised upward in subsequent years. Not only does the Eco-Design Directive systematically raise the minimum requirements with respect to environmental performance, the method used to measure this performance has also been changed to better reflect real-life conditions. The new seasonal performance rating provides a much more accurate picture of actual expected energy efficiency over an entire heating or cooling season. Completing the picture is a new energy label for EU. The present label, introduced in 1992 and modified in the meantime, allows consumers to compare and make purchasing decisions based on uniform labelling criteria. The new label includes multiple classifications from A+++ to D reflected in colour shadings ranging from dark green (most energy efficient) to red (least efficient). Information on the new label includes not only the new seasonal efficiency ratings for heating (SCOP) and cooling (SEER), but also annual energy consumption and sound levels. It will allow end-users to make even better informed choices, since seasonal efficiency reflects air conditioner or heat pump

The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Fan coil units (FCU) and Air handling units (AHU). Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com

Daikin products are distributed by:

FSC

ECPEN14-130 Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

ECPEN14-130 • CD • 05/14 • Copyright Daikin The present publication supersedes ECPEN13-130_SE. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

efficiency over an entire season.