Construction details - Tata Steel Construction

27 downloads 264 Views 4MB Size Report
May 5, 2004 - These construction recommendations are based on state-of-the-art technology. They are provided to the best
Corus Bausysteme

Construction details Kalzip® roof systems

Preface

Planning Guidance

Kalzip® aluminium roofing systems are suitable for a wide variety of applications and not only offer a lengthy service life but also excellent economic efficiency. Their compliance with the current requirements of construction physics relating to fire/acoustic protection and the EnEV energy-saving directives is exemplary. These construction recommendations are based on state-of-the-art technology. They are provided to the best of our knowledge and based on our experience and studies. They do not refer to any specific application and cannot give rise to any claims for compensation. We reserve the right to make any changes to the construction or product range which seem technically sensible in view of our high demands for quality and progress. The vendor accepts no liability for the advice rendered to the purchaser within the framework of the technical service which he provides. All drawings, sales documents or other suggested structures, procedures and ideas are presented without obligation to the purchaser for checking. It is the duty of the purchaser to ensure that there is no infringement of the trade mark rights (protection rights/industrial property rights?) of a third party. The constructional details represent suggestions for roof structures designs which have two shells and must be adapted to suit the actual constructional facts and conditions. The design of these types of structures requires careful planning, calculation, skilled preparation and installation. For this reason, all conditions and facts relating to use, in particular those relating to construction physics, must be taken into consideration. Standard constructions, which fulfil all requirements, are not possible.

Kalzip® plastic compound clip Kalzip® compound clips are not available in all sizes. All details are also applicable to the use of aluminium clips. Standards/instructions The current applicable standards and manufacturer’s instructions should be observed. Air tightness All room sealing connections should be made air-tight in accordance with the EnEV energy-saving directives. Fixed points/ fasteners Fixed points and featured fasteners should be used in accordance with the static calculations.

May 2004 This construction guide replaces all previous construction details.

Contents

Construction details truss roof/purlin roof Construction 101 102

Kalzip® deck roof system - rafter roof Kalzip® deck roof system - purlin roof

Ridge

121 122 123 124 125 126

Duo-pitch ridge Duo-pitch ridge Mono-pitch ridge Abutment ridge to parapet Mono-pitch ridge overhang (with clip bar) Mono-pitch ridge overhang (without clip bar)

purlin roof truss roof truss roof truss roof truss roof truss roof

Eaves

141 142 143 144 145 146

Eaves detail with gutter Eaves detail with gutter Parapet eaves gutter detail Overhanging eaves (with clip bar) Overhanging eaves (without clip bar) Valley gutter detail

purlin roof truss roof truss roof truss roof truss roof truss roof

Ridge

161 162 163 164 165 166 167 168

Verge Verge Abutment to parapet Verge with Kalzip® transition sheet Cantilevered verge Cantilevered verge with steel plate bracket Curved verge Curved verge with Kalzip® transition sheet

purlin roof truss roof truss roof truss roof truss roof purlin roof truss roof truss roof

Construction details rafter roof Construction 201 202

Roof construction with rafter insulation Roof construction Kalzip® AF with intermediate rafter insulation

rafter roof rafter roof

Ridge

221 222 223 224

Ridge with fixed point Abutment ridge to parapet Cantilevered ridge with clip bar Overhanging ridge with cantilever rafter

rafter rafter rafter rafter

roof roof roof roof

Eaves

241 242 243 244 245

Dripping eaves Cantilevered dripping eaves with clip bar Overhanging ridge with cantilever rafter Dripping eaves Kalzip® AF Dripping eaves Kalzip® AF/ventilated masonry

rafter rafter rafter rafter rafter

roof roof roof roof roof

Ridge

261 262 263 264

Overhanging Overhanging Overhanging Overhanging

rafter rafter rafter rafter

roof roof roof roof

verge verge with Kalzip® transition sheet verge with Kalzip® AF round verge

Supplementary construction details Hip

301 302

Hip with ridge closure Welded hip with Kalzip® transition sheet

purlin roof purlin roof

Groove

303 304 305

Groove with gutter Groove with Kalzip® AF Groove on building unit with expansion member

rafter roof rafter roof

Contents

Roof-light

311 312 313 314 315

Domed roof-light roofing frame Cross-section roof-light with flat flange - roofing frame Cross-section roof-light with flat flange Cross-section roof-light with Kalzip® roofing frame Longitudinal roof-light with Kalzip® roofing frame

truss truss truss truss

roof roof roof roof

Roof lights

321 322 323 324

Lighting Lighting Lighting Lighting

truss truss truss truss

roof roof roof roof

Joints

331 332

Curved roof with welded ridge jolt Curved roof with sealed lateral jolt

truss roof truss roof

Stepped roofs

341 342

Lowered dripping eaves Lowered verge

rafter roof rafter roof

Expansion joint

351

Expansion joint Kalzip®

truss roof

Ridge

361 362 363

Ridge flashing - cantilevered Sliding ridge - Duo-pitch roof Ventilated ridge

truss roof rafter roof

row row row row

connection, below gable end connection, below gable end connection, below gable end joint - lateral

Construction details Kalzip NatureRoof® Ridge

401 402 403

Duo-pitch ridge Mono-pitch ridge Mono-pitch roof with attic

purlin roof truss roof truss roof

Eaves

411 412

Dripping eaves detail with gutter Dripping eaves with parapet

purlin roof truss roof

Verge

421 422 423

Verge Verge with parapet Verge with Kalzip® transition sheet

purlin roof truss roof truss roof

Additions

431 432 433 434

Installation and shearing protection Domed rooflight Internal box gutter thermally insulated Curved roof with welded ridge jolt

truss truss truss truss

roof roof roof roof

Construction details Kalzip Duo® and Kalzip DuoPlus® Construction

Additions

501 502 503 504 505 506

Roof Roof Roof Roof Roof Roof

construction construction construction construction construction construction

511 521 531

Duo-pitch ridge Dripping eaves Verge

with trapezoidal steel deck with aerated concrete roof slaps with upper insulation intermediate rafter insulation with trapezoidal steel profile (structural deck)

truss roof truss roof purlin roof rafter roof rafter roof truss roof purlin roof truss roof truss roof

Construction detail 101 Kalzip® deck roof system - rafter roof Cross-section

Compound clip* (diagonally installed) Alternative: Al-clip with thermal barrier Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer

Structural deck Rafter

Horizontal section

Compound clip* (diagonally installed) Alternative: Al-clip with thermal barrier Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer

Structural deck Rafter * Compound clips are not available in all sizes.

Detail 101

01.02.04 scale 1:10

Construction detail 102 Kalzip® deck roof system - purlin roof Cross-section Compound clip* Alternative: Al-clip with thermal barrier Top-hat sub-purlin Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer

Structural deck Purlin Rafter

Horizontal section Compound clip* Alternative: Al-clip with thermal barrier Top-hat sub-purlin Kalzip® Kalzip® rock wool insulation Kalzip® vapour control layer

Structural deck Purlin Rafter * Compound clips are not available in all sizes.

01.02.04 scale 1:10

Detail 102

Construction detail - Kalzip® liner-deck roof system - purlin roof 121 Duo-pitch ridge

Type of fixed point to be determined by calculation

Alternative: Fixed point clip Al-clip with thermal barrier

Ridge flashing

Fixed point clip Compound clip*

Spacer profile Fixing of ridge flashing: max. distance 400 mm, only into ridge closure

Filler block

Ridge turn up

≥ 100

Ridge closure

≥ 70

Kalzip®

Ridge flashing

Liner deck

Insulation - rigid**

Top-hat sub-purlin

Kalzip® vapour control layer

Purlin

Kalzip rock wool insulation

Rafter

®

Inner skin flashing

* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.

Detail 121

01.02.04 scale 1:5

Construction detail - Kalzip® deck roof system - rafter roof 122 Duo-pitch ridge

Type of fixed point to be determined by calculation

Ridge flashing Alternative: Fixed point clip Al-clip with thermal barrier Fixing of ridge flashing: max. distance 400 mm, only into ridge closure

Fixed point clip Compound clip*

Spacer profile Ridge turn up

Filler block Ridge closure

≥ 100

≥ 70

Kalzip®

Kalzip® rock wool insulation Insulation - rigid**

Structural deck

Kalzip® vapour control layer

Rafter

* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.

01.02.04 scale 1:5

Detail 122

Construction detail - Kalzip® deck roof system - rafter roof 123 Mono-pitch ridge

Type of fixed point to be determined by calculation

Al-Fixed point clip with thermal barrier Alternative: Compound clip*

Kalzip® Kalzip® rock wool insulation

Filler block

Spacer profile

Fixing of ridge flashing: max. distance 400 mm, only into Ridge closure

Ridge turn up Ridge flashing Retainer

Ridge closure

Kalzip® vapour control layer

Insulation - rigid**

Slosure profile to structural liner tray Sealing strip 2x

Structural deck

Kalbau® trapezoidal deck

Internal closure flashing

Structural liner tray

Insulation

Sealing strip

Thermal isolation strip

* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.

Detail 123

01.02.04 scale 1:5

Construction detail - Kalzip® deck roof system - rafter roof 124 Abutment ridge to parapet

Ridge flashing Spacer profile Ridge turn up

Coping system Timber bearer

Fixed point clip Compound clip* Alternative: Al-clip with thermal barrier

Coping bracket

Filler block Fixing of ridge flashing: max. distance 400 mm; not into standing seam

≥ 100

Ridge closure

≥ 70

Kalzip®

Kalzip® rock wool insulation Structural deck Insulation - rigid** Kalzip vapour control layer ®

Internal closure flashing Sealing strip

* Compound clips are not available in all sizes. ** Special precautions must be taken when soft thermal insulation is used to prevent penetration.

01.02.04 scale 1:5

Detail 124

Detail 125 Internal closure flashing

Structural top hat supports

Kalzip® vapour control layer

Structural deck

on by calculati

Timber spacer

determined

on by calculati determined

Insulation

Structural liner tray

Kalbau®

Sealing strip 2x

Thermal isolation strip

Closure profile to structural liner tray

Kalbau®

) (max. 1500

Ridge closure

Ridge turn up

Spacer profile

Al-clip bar

Kalzip® rock wool insulation

Flashing

Filler block

Kalzip®

Fixed point to be determined by calculation Fixing of ridge flashing: max. distance 400 mm, not into standing seam

Construction detail - Kalzip® deck roof system - rafter roof 125 Mono-pitch ridge overhang (with clip bar)

01.02.04 scale 1:5

01.02.04 scale 1:5 Internal closure flashing

Structural deck

Kalzip® vapour control layer

Timber supports

Kalzip® rock wool insulation

Kalzip®: Length min. 5,0 m

Timber ridge bearer

AL-fixed point clip length to be determined by calculation

) (max. 1000

Insulation

Structural liner tray

Kalbau® trapezoidal profile

Sealing strip 2x

Thermal isolation strip

Closure profile to structural liner tray

Angle with sealing strip

on by calculati determined

‘Eaves’ filler block

Drip angle

‘Eaves’ filler block

Construction detail - Kalzip® deck roof system - rafter roof 126 Mono-pitch ridge overhang (without clip bar)

Detail 126

Construction detail - Kalzip® liner-deck roof system - purlin roof 141 Eaves detail with gutter

Compound clip*

Alternative

Filler block Drip angle

Closure flashing Timber eaves bearer Timber spacer

Kalzip® Kalzip® rock wool insulation

Sealing strip

Kalzip® vapour control layer Insulation - rigid

Al-clip

Gutter Gutter brackets Closure flashing Liner-deck Purlin Rafter

* Compound clips are not available in all sizes.

Detail 141

01.02.04 scale 1:5

Construction detail - Kalzip® deck roof system - rafter roof 142 Eaves detail with gutter

Kalzip®

Gutter

Insulation rigid

Filler block Drip angle

Timber spacer Kalzip® vapour control layer

Closure flashing Gutter brackets

Kalzip rock wool insulation ®

Timber eaves bearer Al-clip

Thermal isolation strip

Closure profile to structural liner tray

Structural deck

Internal closure flashing

Rafter Sealing strip 2x

Structural liner tray

Insulation

Kalbau® SN 18/76

01.02.04 scale 1:5

Detail 142

Detail 143

Rainwater pipe

Gutter liner outlet

Gutter outlet

Circular sealing strip

Rafter

Structural deck

Kalzip® rock wool insulation

Compound clip* Alternative: Al-clip with thermal barrier

Kalzip® vapour control layer

Insulation - rigid

Kalzip®

Emergency overflow

Filler block

Drip angle

Insulation retainer

Gutter liner (fully sealed)

Insulation - rigid

Gutter

Sealing strip

Closure flashing

Z-Profile

Kalbau® trpezoidal profile

Timber

Coping bracket

Coping system

Construction detail - deck roof system - rafter roof 143 Parapet eaves gutter detail

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

01.02.04 scale 1:5

Kalzip® vapour control layer

Top-hat sub-purlin

Spacer profile

Rafter

Sealing strip 2x

Internal closure flashing

Structural deck

determined by calculation

Drip angle

Kalzip® rock wool insulation

Kalbau® SN 18/76

Insulation

Structural liner tray

Closure profile to structural liner tray

Thermal isolation strip

Kalbau® SN 18/76

determined by calculation (m ax. 1500)

Gutter brackets

Filler block

Gutter

Al-clip bar

Kalzip®

Construction detail - deck roof system - rafter roof 144 Overhanging eaves (with clip bar)

Detail 144

Detail 145 Rafter

Sealing strip 2x

Internal closure flashing

Structural deck

Kalzip® vapour control layer

Timber spacer

Kalzip® rock wool insulation

Kalzip®: Lenght min. 5,0m

Timber eaves bearer

Al-clip length determined by calculation

Kalbau® trapezoidal profile

Insulation

Structural liner tray

Closure profile to structural liner tray

Thermal isolation strip

Gutter brackets

Al-clip: length 200 mm 2 rivets on the small rib

Drip angle

Filler block

Gutter

Construction detail - Kalzip® deck roof system - rafter roof 145 Overhanging eaves (without clip bar)

01.02.04 scale 1:5

01.02.04 scale 1:5

Alternative without timber eaves bearer

Rainwater pipe

Gutter liner outlet

Gutter outlet

Circular sealing strip

Kalzip® rock wool insulation

Kalzip® vapour control layer

Compound clip*

Insulation - rigid

Kalzip®

Closure flashing

Drip angle

Filler block

Gutter liner (fully sealed)

Insulation - rigid

Gutter

Emergency overflow

Closure flashing

Timber spacer

Rafter

Structural deck

Alternative with timber eaves bearer

Timber eaves bearer

Al-clip

Construction detail - Kalzip® deck roof system - rafter roof 146 Valley gutter detail

* Compound clips are not available in all sizes.

Detail 146

Construction detail - Kalzip® liner-deck roof system - purlin roof 161 Verge

Al-clip Tolerance profile

Sealing strip

Gable end channel

Timber verge bearer

Gable end clip

Kalzip®

Verge flashing

Kalzip® rock wool insulation

Retainer flashing Compound clip* Alternative: Al-clip with thermal barrier

Closure flashing Tolerance

Top-hat sub-purlin Kalzip® vapour control layer

Kalzip ® TF 800 R

Liner deck Interal closure flashing

Purlin Rafter

* Compound clips are not available in all sizes.

Detail 161

01.02.04 scale 1:5

Construction detail - Kalzip® deck roof system - rafter roof 162 Verge

Alternative

Verge profile Tolerance

Al-clip

Timber verge bearer

Tolerance profile

Kalzip®

Gable end channel

Kalzip® rock wool insulation

Gable end clip

Compound clip* Alternative: Al-clip with thermal barrier

Verge flashing

Tolerance

Flashing retainer support Kalzip® vapour control layer

Structural deck Sealing strip Rafter * Compound clips are not available in all sizes.

05.05.04 scale 1:5

Detail 162

Construction detail - Kalzip® deck roof system - rafter roof 163 Abutment to parapet

Alternative

Coping system Coping bracket Timber bearer

min. 150

Z-Profil Kalbau® trapezoidal profile

Retainer flashing Kalzip® transition sheet

Verge flashing Gable end clip

Insulation - rigid

Gable end channel Tolerance

Kalzip® Compound clip* Alternative: Al-clip with thermal barrier

Tolerance profile

Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck Insulation - rigid Sealing strip

* Compound clips are not available in all sizes.

Detail 163

01.02.04 scale 1:5

Construction detail - Kalzip® deck roof system - rafter roof 164 Verge with Kalzip® transition sheet

Closure flashing Flashing retainer/support Kalzip® transition sheet Compound clip* Alternative: Al-clip with thermal barrier Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck

Internal closure flashing Sealing strip

Kalzip® TF 800 R

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 164

Detail 165

Kalbau® SN 18/76

Kalbau® SN 18/76

Insulation

Structural liner tray

Closure profile to structural liner tray

Sealing strip

Thermal isolation strip

Thermal isolation

Top-hat support profile

Structural deck

determined by calculation

Kalzip® vapour control layer

Kalzip® transition sheet

Top-hat support

Kalzip® rock wool insulation

Flashing retainer/support

Rectangular hollow section

Al-clip with thermal barrier

Kalzip®

Construction detail - Kalzip® deck roof system - rafter roof 165 Cantilevered verge

01.02.04 scale 1:5

01.02.04 scale 1:5

Al-clip

Omega profile

Gable end clip

®

Kalbau SN 18/76

Purlin

Thermal isulation

Internal closure flashing

Rafter

Liner-deck

Vapour control layer clamped sealed

Steel plate bracket

Compound clip* Alternative: Al-clip with thermal barrier

Top-hat sub-purlin

Kalzip® vapour control layer

Kalzip® rock wool insulation

Kalzip®

Construction detail - Kalzip® liner-deck roof system - purlin roof 166 Cantilevered verge with steel plate bracket

* Compound clips are not available in all sizes.

Detail 166

Construction detail - Kalzip® deck roof system - rafter roof 167 Curved verge

Curved verge flashing

Perforated closure flashing Flashing retainer/support Gable end clip Gable end channel (curved by slotting) Tolerance profile (in short lenghts)

Convex Kalzip® Kalzip® rock wool insulation Compound clip* Alternative: Al - clip with thermal barrier

Ri Vapour control layer clamped and sealed

Kalzip® vapour control layer Structural deck

Kalbau® SN 18/76

Closure flashing

* Compound clips are not available in all sizes.

Detail 167

01.02.04 scale 1:5

Construction detail - rafter roof 168 Curved verge with Kalzip® - transition sheet

Kalzip® transition sheet - curved

Compound clip* Alternative: Al-clip with thermal barrier

Perforated closure flashing Flashing retainer/support

Kalzip® rock wool insulation Convex Kalzip®

Ri Vapour control layer clamped and sealed Kalbau® SN 18/76

Kalzip® vapour control layer Structural deck Closure flashing

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 168

Construction detail rafter roof 201 Roof construction with rafter insulation Cross-section Compound clip* Alternative: Al-clip with thermal barrier Timber (min. 10/6) Kalzip®

Timber rater Timber shuttering Kalzip® vapour control layer H Kalzip® rock wool insulation

Longitudinal section Timber (min. 10/6) Compound clip* Alternative: Al-clip with thermal barrier Kalzip®

Timber rater Timber shuttering Kalzip® vapour control layer H Kalzip® rock wool insulation

Detail 201

* Compound clips are not available in all sizes.

01.02.04 scale 1:10

Construction detail rafter roof 202 Roof construction Kalzip® AF with intermediate rafter insulation Cross-section Compound clip E10 (diagonally installed) Alternative: Al-clip L10 Precovering (open for diffusion) Kalzip® AF Timber shuttering

Timber rater Kalzip® rock wool insulation Kalzip® vapour control layer Timber lathing Interior lining layer

Longitudinal section Kalzip® AF Compound clip E10 (distributed installed) Alternative: Al-clip L10 Precovering (open for diffusion)

Timber rater Timber shuttering Kalzip® rock wool insulation Kalzip® vapour control layer Timber lathing Interior lining layer

01.02.04 scale 1:10

Detail 202

Detail 221

Kalzip® rock wool insulation

Thermal insulation - rigid

Ridge closure

Filler block

Type of fixed point to be determined by calculation * Compound clips are not available in all sizes.

Kalzip® vapour control layer H

Timber shuttering

Timber rafter

Fixing of ridge flashing: max. distance 400 mm, into ridge closure

Fixed point clip determined by calculation Compound clip*

Timber

Fixed point clip determined by calculation; Al-clip ≥ 70

Ridge flashing

Ridge turn out

0 ≥ 10

Kalzip®

Spacer profile

Construction detail - rafter roof 221 Ridge with fixed point

01.02.04 scale 1:5

Construction detail - rafter roof 222 Abutment ridge to parapet

Type of fixed point to be determined by calculation

Coping system Timber eaves bearer Coping bracket

Ridge flashing Spacer profile Ridge turn up Kalzip® rock wool insulation Timber Fixed point clip determined by calculation; Compound clip* Filler block



100

≥ 70

Ridge closure Kalzip®

Clip track with sealing strip Timber rafter Timber shuttering Kalzip® vapour control layer H Thermal insulation - rigid

01.02.04 scale 1:5

* Compound clips are not available in all sizes.

Detail 222

Detail 223

ulati

on

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

calc d by e n i rm dete

Al-clip bar

Kalzip®

Kalzip® rock wool insulation

Timber supports

Filler block rm dete

ined

by

0 . 150

)

Drip angle with sealing strip

Filler block

Panel

Insulation

Alternative

Clipping track with sealing strip

Stripping felt

Kalbau® SN 18/76

Spacer profile

Closure flashing

Filler block

Ridge closure

(max tion a l u calc

Construction detail - rafter roof 223 Cantilevered ridge with clip bar

01.02.04 scale 1:5

01.02.04 scale 1:5

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

Kalzip® rock wool insulation

Timber spacer

Kalzip®

Drip angle

Clipping track with sealing strip

Ridge closure

Cantilever rafter

Timber shuttering

Insulation

Filler block

Flashing

Timber bearer

Fixed point clip Al-clip

Construction detail - rafter roof 224 Overhanging ridge with cantilever rafter

Detail 224

Construction detail - rafter roof 241 Dripping eaves

Gutter Filler block Drip angle Closure flashing Gutter brackets Closure flashing Flashing retainer Timber eaves bearer Timber spacer Al-clip

20

Kalzip®

Timber rafter Timber shuttering Kalzip® vapour control layer H Thermal insulation - rigid Kalzip® rock wool insulation

Detail 241

01.02.04 scale 1:5

01.02.04 scale 1:5

Gutter

Gutter brackets

Clipping track with sealing strip

Connecting angle

Kalbau® SN 18/76

y ed b rmin e t e d

500) ax. 1 m ( n latio calcu

Drip angle

Filler block

Kalzip

®

Al-clip bar

Timber

Timber spacer

Kalzip® rock wool insulation

ulati

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

Timber supports

alc by c ned i m r dete

on

Construction detail - rafter roof 242 Cantilevered eaves with clip bar

Detail 242

Detail 243 Sealing strip

Closure profile

Cantilever rafter

Kalzip®

Al-clip

Timber eaves bearer

Closure flashing

Drip angle

Filler block

Gutter

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

Kalzip® rock wool insulation

Timber spacer

Construction proposal rafter roof 243 Overhanging dripping eaves with cantilever rafter

01.02.04 scale 1:5

Alternative

01.02.04 scale 1:5 Gutter

Filler block

Drip angle

Closure flashing

Compound clip E10

Exposed shuttering

Kalzip® AF

Coping rafter

Embeding gutter brackets

Exposed shuttering

Al-clip

Kalzip®

Precovering (open for diffusion)

Timber shuttering

Timber rafter

Kalzip® rock wool insulation

Timber lathing

Interior lining layer

Kalzip® vapour control layer

Clipping track with sealing strip

Construction detail - rafter roof 244 Dripping eaves Kalzip® AF

Detail 244

Detail 245

Kalzip® AF

Exposed shuttering

Perforatet metal sheet

Gutter

Filler block

Drip angle

Closure flashing

Compound clip E10

Precovering (open for diffusion)

Timber shuttering

Timber rafter

Kalzip® rock wool insulation

Timber lathing

Interior lining layer

Kalzip® vapour control layer

Clipping track with sealing strip

Construction detail - rafter roof 245 Dripping eaves Kalzip® AF/ventilated masonry

01.02.04 scale 1:5

01.02.04 scale 1:5 Tolerance profile Verge flashing

Kalzip®

Al-clip

Timber spacer

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

Clipping track with sealing strip

Flashing retainer - two-part

Cantilever purlin

Timber shuttering

Gable end channel

Kalzip® rock wool insulation

determined by calculation

Gable end clip

Purlin

Construction detail - rafter roof 261 Overhanging verge

Detail 261

Detail 262 Timber shuttering

Al-clip

Timber spacer

Timber rafter

Timber shuttering

Kalzip® vapour control layer H

Clipping track with sealing strip

determined by calculation

Kalzip® transition sheet

Kalzip®

Cantilever purlin

Flashing retainer

Kalzip® rock wool insulation

Construction detail - rafter roof 262 Overhanging verge with Kalzip® transition sheet

01.02.04 scale 1:5

01.02.04 scale 1:5

Kalzip® rock wool insulation

Kalzip® vapour control layer H

Timber lathing

Interior lining layer

Clipping track with sealing strip

Timber shuttering

Exterior rafter lower

Exposed shuttering

Kalzip® AF transition sheet

Compound clip E10 Alternative: Al-clip

Precovering (open for diffusion)

Flashing retainer

Kalzip® AF profile sheet

Construction detail - rafter roof 263 Overhanging verge Kalzip® AF

Detail 263

Detail 264

Timber spacer

Timber rafter

determined by calculation

Kalzip® rock wool insulation

Timber shuttering

Kalzip® vapour control layer H

Clipping track with sealing strip

Kalzip®

Al-clip

Cantilever purlin

Alternative

Gable end clip Curved gable end channel

Tolerance profile (in short lenghts)

Curved verge flashing

Flashing retainer

Kalzip® transition sheet

Construction detail - rafter roof 264 Overhanging round verge

01.02.04 scale 1:5

Construction detail - purlin roof 301 Hip with ridge closure

Type of fixed point to be determined by calculation Ridge turn up

Spacer profile

Fixed point clip Compound clip*

Ridge flashing Filler block

≥ 100

≥ 70

Ridge closure Kalzip®

Insulation - rigid

Hip purlin

Kalzip vapour control layer

Top-hat sub-purlin

Kalzip rock wool insulation

Structural liner-deck

®

®

Fixing of ridge flashing: max. distance 400 mm, not into standing seam

Ridge flashing Spacer profile Filler block Ridge closure Kalzip®

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 301

Construction detail - purlin roof 302 Welded hip with Kalzip® transition sheet

Fixed point clip Compound clip* Kalzip® Welding seam Kalzip® welding basis Kalzip® transition sheet

Insulation - rigid (not inflammable) Kalzip® vapour control layer

Hip purlin Structural deck Top-hat sub-purlin

Kalzip® rock wool insulation

Type of fixed point to be determined by calculation

Kalzip® transition sheet Welding seam Kalzip®

* Compound clips are not available in all sizes.

Detail 302

01.02.04 scale 1:5

01.02.04 scale 1:5

Kalzip® vapour control layer H

Timber shuttering

Timber rafter

Timber spacer

Kalzip® rock wool insulation

Thermal insulation - rigid

Compound clip E10

Timber eaves bearer

Filler block

Drip angle

Kalzip®

Flashing

Construction detail - rafter roof 303 Groove with gutter

Detail 303

Detail 304

Compound E10

Internal lining layer

Timber lathing

Kalzip® vapour control layer

Coping timber rafter

Kalzip® rock wool insulation

Timber shuttering

Precovering (open for diffusion)

Filler block

Drip angle

Kalzip® AF

Gutter metal sheet

Construction detail 304 Groove with gutter Kalzip® AF

01.02.04 scale 1:5

Construction detail 305 Groove on building unit with expansion member

Wall connection profile sealed Cantilever metal sheet Flashing

Expansion member (1-head) Insulation - compressible Welding joint

approx. 500

Kalzip® Kalzip® transition sheet

01.02.04 scale 1:5

Detail 305

Construction detail 311 Domed roof-light roofing frame

Domed roof-light Flat flange-roofing frame (to weld)

Light cupola-skylight Attaching frame Flat flange-roofing frame Upper conecting frame

Domed roof-light Kalzip® roofing frame (standing seam)

Flashing Attaching frame Kalzip® roofing frame Upper conecting frame Light cupola-skylight

Detail 311

01.02.04 scale 1:5

01.02.04 scale 1:5

Rafter

Roofing frame

* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame

Kalzip® rock wool insulation

Insulation - rigid (not inflammable)

min. 200

Flashing profile

Order size

x x

Insulation

Welding seam

Kalzip®

Compound clip*

Kalzip® vapour control layer

100

Longitudinal beam determined by calculation

min. 200

x

Height

Structural deck

Kalzip® welding basis

Flat flange roofing frame

Upper connecting frame

Domed roof-light**

l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm

Construction detail 312 Cross-section roof-light with flat flange - roofing frame

Detail 312

Construction detail 313 Cross-section roof-light with flat flange

Domed roof-light** Upper connecting frame Flat flange - roofing frame Welding seam Kalzip® welding basis Cut Kalzip® sheet

Height

Compound clip*

100

Kalzip®

Ordering size

Kalzip® rock wool insulation Kalzip® vapour control layer Cross beam determined by calculation Insulation - rigid (not inflammable) Structural deck Framing profile Roofing frame

* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame

Detail 313

01.02.04 scale 1:5

01.02.04 scale 1:5

Rafter

Roofing frame

Roofing frame

Longitudinal profile determined by calculation

100

Ordering size

Height

Structural deck

Fixed point clip

Ridge closure + filler block

Ridge flashing

Ridge turn up

Spacer profile

Upper connecting frame

Domed roof-light**

Insulation - rigid (not inflammable)

Kalzip® welding basis

min. 200

* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame

Kalzip® rock wool insulation

Kalzip® vapour control layer

x x

Kalzip® roofing frame

Welding seam

Kalzip®

Compound clip*

l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm

Construction detail 314 Cross-section roof-light with Kalzip® roofing frame

Detail 314

Construction detail 315 Longitudinal roof-light with Kalzip® roofing frame

Domed roof-light** Upper connecting frame Kalzip® roofing frame

Height

Compound clip*

100

Kalzip®

Ordering size

Kalzip® rock wool insulation Profile determined by calculation Kalzip® vapour control layer Structural deck Insulation - rigid (not inflammable) Flashing profile Roofing frame

* Compound clips are not available in all sizes. ** Domed rooflight: complete with curb, light dome, cantilever metal sheet and frame

Detail 315

01.02.04 scale 1:5

Construction detail 321 Lighting row connection, below gable end · truss roof

l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm

Cantilever metal sheet Flashing Kalzip® welding basis Welding seam Compound clip*

Kalzip®

x x

min. 200

Insulation compressible Insulation Lighting row frame Sealing strip

Structural deck

Kalzip® rock wool insulation

Trimmer beam Rafter

Kalzip® vapour control layer Insulation - rigid (not inflamable)

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 321

Construction detail 322 Lighting row connection, below gable end · truss roof

Spacer profile Ridge flashing Ridge closure + filler block Fixing of ridge flashing: max. distance 400 mm, not into standing seam Kalzip® Fixed point clip Compound clip*

Insulation Lighting row frame Sealing strip

Kalzip® rock wool insulation

Structural deck Trimmer beam

Insulation - rigid

Rafter

Kalzip vapour control layer ®

* Compound clips are not available in all sizes.

Detail 322

01.02.04 scale 1:5

Construction detail 323 Lighting row connection, below gable end · truss roof

l = distance fixed point - domed roof-light [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm

Cantilever metal sheet Ridge flashing Kalzip® welding basis Welding seam Kalzip® Compound clip* x x

Insulation compressible

min. 200 Insulation Lighting row frame Sealing strip

Kalzip® rock wool insulation

Structural deck Trimmer beam

insulation - rigid (not inflammable)

Rafter

Kalzip® vapour control layer

* Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 323

Detail 324

* Compound clips are not available in all sizes.

Tolerance profile

Tolerance

Gable end channel

Gable end clip

Verge flashing

Alternative

Sealing strip

Lighting row frame

Insulation

min. 150

Trimmer beam

Insulation - rigid

Structural deck

Kalzip® vapour control layer

Kalzip® rock wool insulation

Kalzip® transition sheet

Cantilever metal sheet

Compound clip*

Kalzip®

Construction detail - rafter roof 324 Lighting row joint - lateral

01.02.04 scale 1:5

01.02.04 scale 1:5 Welded joint

Rafter

Structural deck

®

Kalzip

Alternative: Fixed point clip Al-clip with thermal barrier

Kalzip® vapour control layer

Insulation - rigid (not inflammable)

Kalzip® welding basis

Type of fixed point to be determined by calculation

100

Ri

Kalzip ®

* Compound clips are not available in all sizes.

Fixed point clip Compound clip* Kalzip® rock wool insulation

Kalzip®

Construction detail - trussed roof 331 Curved roof with welded ridge jolt

Detail 331

Detail 332

Approved aluminiumseal rivet Ø 4,8 mm with stainless steel bolt

Rafter

Seal scheme for Kalzip® with two beads

Ri

Structural deck

Kalzip® vapour control layer

®

Kalzip rock wool insulation

Kalzip®

200

Silic

ping

ours

Silicone

200 one

rlap

r Ka lzip ® c

Ove

uppe e

Incl inat min

100

ion: . 2, 9°

low er lzip ® co urs

e

* Compound clips are not available in all sizes.

Compound clip*

Ka

Construction detail - rafter roof 332 Curved roof with sealed lateral jolt

01.02.04 scale 1:5

01.02.04 scale 1:5

Kalzip®

Al-clip

Kalzip® rock wool insulation

Kalzip® vapour control layer H

Ridge closure + filler block

Flashing

Drip angle

Filler block

Plank (min. 10/6)

Gutter

Closure flashing

Timber shuttering

Visible shuttering

Timber rafter

Flashing retainer

Compound clip*

Kalzip® rock wool insulation Insulation - rigid

* Compound clips are not available in all sizes.

Construction detail - rafter roof 341 Lowered dripping eaves

Detail 341

Detail 342

Kalzip®

Kalzip® rock wool insulation

Compound clip*

Kalzip® transition sheet

Supporting profile

Kalzip® vapour control layer H

Timber

Timber rafter

External rafter lower

Al-clip

Visible shuttering

Timber shuttering

Kalzip® transition sheet

Insulation - rigid

Flashing retainer

* Compound clips are not available in all sizes.

Construction detail - rafter roof 342 Lowered verge

01.02.04 scale 1:5

Construction detail -rafter roof 351 Expansion joint Kalzip®

Flashing

Section A-A

Holder

* Compound clips are not available in all sizes.

Flashing retainer

Gable end clip Flashing

Gable end channel

Holder

Compound clip*

Flashing retainer

A

Strain

A Kalzip®

Strain

Kalzip® rock wool insulation

Structural deck Rafter

Kalzip® vapour control layer

01.02.04 scale 1:2,5

Flat metal strip (fixed on one side)

Detail 351

Fixing of ridge flashing in ridge closure: max. distance 400 mm; not into standing seam

Detail 361 2 rows sealing matter

Fixing within the overlapping only for the lower ridge flashing

Kalzip®

Ridge turn up

Ridge closure

Spacer profile

Filler block

Ridge flashing L = max. 6,0 m

Construction detail 361 Ridge flashing - cantilevered

02.07.03 scale 1:5

Construction detail - rafter roof 362 Sliding ridge - Duo-Pitch roof

Cross-section scale 1:1

Ridge flashing Sliding member Fixing of ridge flashing on sliding member: max. distance 400 mm; not into standing seam

Kalzip® Clip Sliding potential between Kalzip® and sliding unit

Reinforcing profile

l = distance ridge to fixed point [mm] x = sliding path = l/1000 + min. 5 mm x min. = 20 mm

Ridge turn up Ridge flashing Compound clip*

Fixing of ridge flashing on sliding member: max. distance 400 mm; not into standing seam

Sliding member

≥ 100+x

≥ 70

Filler block Ridge closure Kalzip®

Kalzip® rock wool insulation Insulation - rigid

Structural deck

Kalzip® vapour control layer

Rafter

* Compound clips are not available in all sizes.

01.02.04 scale 1:10

Detail 362

Construction detail - Rafter Roof 363 Ventilated ridge

Ridge turn up

Ridge flashing

Kalbau® structural deck*

Spacer profile

Perforated sheet angle 50/50

Filler block

Fixed point clip Al-clip

≥100

Ridge closure Fixing of ridge flashing: max. distance 400 mm

Kalzip®

Rafter Purlin

* Kalbau® structural deck (trapezoidal profile 50/167) l = 150 mm/construction width = 833 mm

Detail 363

01.02.04 scale 1:5

01.02.04 scale 1:5

≥100

®

Structural deck

Purlin

Kalzip rock wool insulation

≥70

Top-hat sub-purlin

≥100

Fixed point Compound clip*

Ridge flashing

Spacer profile

Ridge turn up

Kalzip vapour control layer ®

Insulation - rigid

Al-beam claw (joint)

Ridge terminal

KD 33 linear drainage system

NDS 60 plant substrate

Planting

* Compound clips are not available in all sizes.

Kalzip® 65/333

Ridge closure

Filler block

Construction detail - purlin roof 401 Duo-Pitch ridge

Detail 401

Construction detail - rafter roof 402 Mono-Pitch ridge

NDS 60 plant substrate

Ridge termination Al-beam claw (joint)

KD 33 linear drainage system

Kalzip® 65/333 Ridge closure

Kalzip® rock wool insulation

Filler block Kalzip® vapour control layer

Ridge flashing

Planting

Spacer profile ≥100

10

Ridge turn up

Insulation - rigid

Closure profile to structural liner tray Sealing strip 2x

Al-fixed point clip with thermal barrier Alternative: Compound clip*

Rafter

Structural deck

Kalbau® structural deck

Internal closure flashing

Structural liner tray

Insulation

Sealing strip

Thermal isolation strip * Compound clips are not available in all sizes.

Detail 402

01.02.04 scale 1:5

Construction suggestions Kalzip NatureRoof® 403 Monopitch roof with attic · truss roof

* Compound clips are not available in all sizes.

Kalzip® 65/333 Ridge turn up Spacer profile Ridge flashing Planting Coping system

NDS 60 plant substrate

Timber KD 33 linear drainage system

Coping bracket

Ridge termination flashing Al-beam claw (joint) Filler block Ridge closure ≥100

≥70

10

≥100

Kalzip® rock wool insulation

Fixed point clip compound clip* Structural deck

Insulation - rigid Kalzip® vapour control layer Rafter

01.02.04 scale 1:5

Internal closure flashing Sealing strip

Detail 403

Construction detail - purlin roof 411 Dripping eaves detail with gutter

Filler block Drip angle Planting NDS 60 plant substrate KD 33 linear drainage system Eaves termination flashing

Closure flashing Timber eaves bearer Timber spacer

Al-beam claw joint Kalzip® 65/333

≥100 Sealing strip Clip

Kalzip® rock wool insulation Kalzip® vapour control layer

Gutter Gutter brackets Flashing

Insulation rigid Purlin Structural deck Rafter

Detail 411

01.02.04 scale 1:5

01.02.04 scale 1:5

Gutter liner outlet

Planting

Rainwater pipe

Gutter outlet

Circular sealing strip

Rafter

Structural deck

10

KD 33 linear drainage system

Compound clip*

Kalzip® rock wool insulation

NDS 60 plant substrate

Al-beam claw (joint)

Eaves termination flashing

Kalzip® vapour control layer

Insulation - rigid

≥100

Emergency owerflow

Filler block

* Compound clips are not available in all sizes.

Inferior steel gutter

Insulation - rigid

Gutter

Sealing strip

Closure profile

Z-profile

Kalbau® structural deck

Timber bearer

Flashing Drip angle

Coping bracket

Kalzip® 65/333

Coping system

Construction detail - rafter roof 412 Dripping eaves with parapet

Detail 412

Construction detail - purlin roof 421 Verge

Sealing strip Timber verge bearer Al-clip

Kalzip®

Tolerance profile

Kalzip® rock wool insulation

Gable end channel

Top-hat sub-purlin Verge termination flashing

Gable end clip

Al-beam claw (joint)

Verge flashing

Compound clip* Retainer flashing Planting

Perforated closure flashing Tolerance

Kalzip® TF 800 R

NDS 60 plant substrate KD 33 linear drainage system Kalzip® vapour control layer Structural deck Internal closure flashing Purlin * Compound clips are not available in all sizes.

Detail 421

Rafter

01.02.04 scale 1:5

Construction detail - rafter roof 422 Verge with parapet

Coping system Coping bracket Timber bearer

Planting NDS 60 plant substrate

Z-profile Kalbau® structural deck

KD 33 linear drainage system Al-beam claw (joint)

Flashing retainer Verge termination flashing Verge flashing Gable end clip

Kalzip® 65/333

Gable end channel

10

Tolerance

Tolerance profile

Compound clip* Kalzip® rock wool insulation Kalzip® vapour control layer Structural deck Insulation - rigid Sealing strip * Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 422

Construction detail - rafter roof 423 Verge with Kalzip® transition sheet

Perforated closure flashing Retainer flashing Kalzip® - transition sheet Compound clip* Alternative: Al-clip with thermal barrier Kalzip® 65/333 Kalzip® rock wool insulation Kalzip® vapour control layer

10

Structural deck

Internal closure flashing Sealing strip

Kalzip® TF 800 R

Al-beam claw (joint) Verge termination flashing KD 33 linear drainage system NDS 60 plant substrate Planting

* Compound clips are not available in all sizes.

Detail 423

01.02.04 scale 1:5

Construction suggestions Kalzip NatureRoof® Additions 431 Installation and shearing protection· truss roof

DN ≤ 5°

Compound clip*

NDS 60 Plant substrate KD 33 linear drainage system

Planting Kalzip® 65/333 Mounting lock

Rafter Structural deck Thermal insulation

DN > 5°

NDS 60 Plant substrate Compound clip*

Kalzip® vapour control layer KD 33 linear drainage system Mounting lock

Planting Kalzip® 65/333 Shearing lock Al-beam claw (joint)

Draina

ge

Rafter Structural deck Thermal insulation

Kalzip® vapour control layer * Compound clips are not available in all sizes.

01.02.04 scale 1:5

Detail 431

Construction suggestions Kalzip NatureRoof® Additions 432 Domed rooflight · truss roof

I = distance fixed point - domed rooflight (mm) x = sliding path = I/1000 + min. 5 mm x min. = 20 mm

KD 33 linear drainage system Domed rooflight** NDS 60 plant substrate Cantilever metal sheet Planting Flat flange-framing Ridge terminal Al-beam claw (joint)

Kalzip® welding basis

Height of the flange

Kalzip® welded

≥100

x x

100

10

min. 200

Order size

Compound clip*

Structural deck Longitudinal beam determined by calculation

Kalzip® vapour control layer

Flashing profile

Kalzip® rock wool insulation

Roofing frame

Insulation - rigid (not inflammable)

Rafter

* Compound clips are not available in all sizes. ** Roof light: complete with curb, roof-light, flange sheet and framing

Detail 432

01.02.04 scale 1:5

01.02.04 scale 1:5 ≥100

Alternative without timber eaves bearer

Rainwater pipe

Gutter outlet Gutter liner outlet

Circular sealing strip

Planting

Closure flashing

Al-clip

Eaves termination flashing

Al-beam claw (joint)

Rafter

Timber spacer

Timber eaves bearer

Structural deck

* Compound clips are not available in all sizes.

Alternative with timber eaves bearer

KD 33 linear drainage system

NDS 60 plant substrate

Emergency overflow

Lower steel gutter (with sealing lateral jolt)

Insulation - rigid

Gutter

Drip angle Framing metal

Filler block

Kalzip® rock wool insulation

Kalzip® vapour control layer

Compound clip*

Insulation - rigid

Kalzip® 65/333

Construction detail - rafter roof 433 Internal box gutter thermally insulated

Detail 433

Detail 434

* Compound clips are not available in all sizes.

Alternative: fixed point clip Al-clip with thermal barrier

Kalzip® vapour control layer

Weleded joint

Rafter

Structural deck

®

Kalzip

Insulation - rigid (not inflammable)

Kalzip® welding basis

Type of fixed point to be determined by calculation

100

Planting

NDS 60 plant substrate

KD 33 linear drainage system

Ri

Kalzip ®

Kalzip®

Kalzip® rock wool insulation

Compound clip*

Construction detail - rafter roof 434 Curved roof with welded ridge joint

01.02.04 scale 1:5

Construction detail - rafter roof Kalzip DuoPlus® 501 Roof construction with trapezoidal steel deck

Kalzip® Kalzip® rock wool insulation DuoPlus clip DuoPlus track 45° direction of span TRP Insulation - rigid h = 100 mm

Kalzip® vapour control layer Structural deck Rafter

01.02.04

Detail 501

Construction detail - rafter roof Kalzip DuoPlus® 502 Roof construction with aerated concrete roof slabs

Kalzip® Kalzip® rock wool insulation DuoPlus clip DuoPlus track 45° direction of span of roof slabs Insulation - rigid h = 100 mm

Kalzip® vapour control layer Aerated concrete roof slabs Rafter

Detail 502

01.02.04

Construction detail - purlin roof Kalzip DuoPlus® 503 Roof construction

Kalzip®

DuoPlus Clip

Kalzip® rock wool insulation

DuoPlus track 90° to direction of span Insulation - rigid h = 100 mm

Purlin Kalzip® vapour control layer Structural deck

01.02.04

Detail 503

Construction detail - rafter roof Kalzip DuoPlus® 504 Roof construction with upper insulation

Kalzip®

DuoPlus Clip

Kalzip rock wool insulation

DuoPlus track 90° to the rafter, fixing into rafter

®

Insulation - rigid h = 100 mm

e≤ 0,8 0

m

Kalzip® vapour control layer H Timber shuttering Timber rafter

* When exceeding the maximum rafter distance e ≤ 0,80m, place DuoPlus track 45° to the rafter and fix it in the shuttering. (length of span according to statics)

Detail 504

01.02.04

Construction detail - rafter roof Kalzip DuoPlus® 505 Roof construction intermediate rafter insulation

Kalzip®

DuoPlus Clip

Kalzip rock wool insulation

DuoPlus track 90° to the rafter, fixing into rafter

®

e≤ 0,8 0

m

Timber rafter Kalzip® vapour control layer Timber lathing Interior lining layer

01.02.04

Detail 505

Construction proposal rafter roof Kalzip Duo® 506 Roof construction with trapezoidal steel profile (structural deck)

Kalzip® Kalzip® rock wool insulation DuoPlus Clip DuoPlus track 45° to direction of span Strip insulation - rigid h = 100 mm, b = 240 mm

Kalzip® vapour control layer Structural deck Rafter

Detail 506

05.05.04

Construction detail - purlin roof Kalzip DuoPlus® 511 Duo-pitch ridge

Ridge turn up Spacer profile Fixing of ridge flashing: max. distance 400 mm, not into standing seam

Ridge flashing Fixed point clip Thermal barrier Filler block

Insulation rigid

≥ 100

≥ 70

Ridge closure Kalzip®

Timber bearer

Structural deck

Kalzip vapour control layer

Top-hat sub-purlin

Insulation - rigid

Purlin

Kalzip rock wool insulation

Rafter

®

®

Ridge flashing furring Ridge flashing

Alternative with timber ridge bearer

01.02.04 scale 1:5

Alternative with top-hat sub-purlin

Detail 511

Construction detail - rafter roof Kalzip DuoPlus® 521 Dripping eaves

DuoPlus Clip

Gutter

Kalzip®

Filler block

Insulation - rigid

Drip angle

Timber spacer Closure flashing Kalzip® rock wool insulation

Gutter brackets Treated timber

Thermal isolation strip

Closure profile to structural liner tray Kalzip® vapour control layer

Internal closure flashing

Structural liner tray

Structural layer

Sealing strip 2x

Insulation

Rafter Kalbau® SN 18/76

Detail 521

01.02.04 scale 1:5

Construction detail - rafter roof Kalzip DuoPlus® 531 Verge

Angel Kalzip® transition sheet Closure profile to structural liner tray

Kalzip® DuoPlus Clip DuoPlus track 45° Kalzip® rock wool insulation

Retainer flashing

Insulation - rigid

Sealing strip

Structural liner tray Insulation

Kalzip® vapour control layer Structural deck

Kalbau® SN 18/76 Sealing strip

Thermal isolation strip

01.02.04 scale 1:5

Detail 531

Notes

www.kalzip.com Austria Corus Bausysteme Bruckner Büro Center Honauerstraße 2 A-4020 Linz · Austria T +43 - 7 32 78 61 14 F +43 - 7 32 78 61 15 [email protected] Belgium Corus Building Systems NV A. Stocletlaan 87 B-2570 Duffel · Belgium T +32 - 15 30 29 22 F +32 - 15 30 29 20 [email protected] Cyprus Phanos N. Epiphaniou Ltd. 21 Markou Drakou Avenue Pallouriotissa P.O. Box 9078 CY-1621 Nicosia Cyprus T +35 - 722 79 35 20 F +35 - 722 43 15 34 [email protected] Czech Republic and Slovakia Engineering Office Eva Sanovcová Cejl 20 CZ-60200 Brno Czech Republic T +42 - 05 45 11 74 40 F +42 - 05 45 11 74 55 [email protected] Denmark Corus ByggeSystemer A/S Kaarsbergsvej 2 Box 136 DK-8400 Ebeltoft Denmark T +45 - 8953 2000 F +45 - 8953 2001 [email protected] France Corus Building Systems SAS 8, Avenue Desclers · B.P. 20 F-77515 Faremoutiers France T +33 - 1 64 65 30 56 F +33 - 1 64 03 98 55 [email protected] Greece Phanos N. Epiphaniou Ltd. 82 Grammou Str. GR-18345 Moschato Greece T +30 - 21 09 40 59 41 F +30 - 21 09 41 24 65 [email protected]

Italy Corus S.C. Milano SpA Via Treves 21/23 I-20090 Trezzano sul Naviglio (Milano) Italy Ufficio Milano Dott. Ing. Giacomo Magnifico Via Merano 13 I-20060 Gessate (MI) · Italy T +39 - 02 95 38 13 07 F +39 - 02 95 38 03 97 [email protected] Ufficio Verona Dott. Ing. Nicola Finato Vicolo Crocioni n.4 I-37122 Verona · Italy T +39 - 045 800 35 49 F +39 - 045 59 33 77 [email protected] The Netherlands HAFKON BV Postbus 46 NL-3140 AA Maassluis The Netherlands T +31 - 105 91 53 00 F +31 - 105 91 51 25 [email protected] Norway Corus Bygg Systemer AS Røraskogen 2 N-3739 Skien · Norway T +47 - 3591 5200 F +47 - 3591 5201 [email protected]

English

Switzerland Büro Dach & Wand Jürg Senteler P.O. Box 247 CH-7302 Landquart · Switzerland T +41 (0) 81 3 22 38 38 F +41 (0) 81 3 22 38 39 [email protected] Turkey Tür Group Architectural Materials Mahmut Sk. No: 8 TR-81200 Kosuyolo-Istanbul · Turkey T +90 - 216 327 4720 F +90 - 216 327 4724 [email protected] United Kingdom and Ireland Corus Building Systems Haydock Lane, Haydock GB-St. Helens · Merseyside WA11 9TY United Kingdom T +44 - 19 42 29 55 00 F +44 - 19 42 27 21 36 [email protected] Overseas: Near East

Poland A-B Space Lukasz Lomozik Ul. Stawowa 31 B PL-43-250 Pawlowice SI. · Poland T +48 - 32 47 25 110 F +48 - 32 47 57 010 [email protected] Portugal Corus Sistemas Constructivos Lda. Av. dos Combatentes 76 Abrunheira P-2710-034 Sintra · Portugal T +35 - 12 19 15 88 00 F +35 - 12 19 15 88 09 [email protected] Spain Corus Sistemas Constructivos S.L.U. Calle Guatemala, 1 Bajos 3 y 4 E-28016 Madrid · Spain T +34 - 9 13 43 03 43 F +34 - 9 13 59 94 73 [email protected]

Corus Bausysteme GmbH August-Horch-Str. 20-22 · D-56070 Koblenz P.O. Box 10 03 16 · D-56033 Koblenz T +49 (0) 2 61 - 98 34-0 F +49 (0) 2 61 - 98 34-100 [email protected]

Sweden Corus ByggSystem AB Sliparegatan 5 · Box 4003 S-300 04 Halmstad · Sweden T +46 - 3510 0110 F +46 - 3515 9200 [email protected]

Lebanon Naggiar Agencies SCS P.O. Box 175415 Beirut Negib Hobeika Street LB-Saifi-Beirut 20296406 Lebanon T +961 - 1 56 26 52 F +961 - 1 44 83 91 [email protected] www.naggiar.com.lb

Overseas: Far East China/Guangzhou Corus Building Systems Suite 1208, West Tower Yang Cheng International Commercial Centre Tian He Ti Yu Dong Road Guangzhou, PR China 510620 T +86 - 20 38 87 01 90/91 F +86 - 20 38 87 02 65 [email protected] www.kalzip.com.cn China/Beijing Corus Building Systems Suite 610, Jing Guang Centre Office Building, Hujialou Chao Yang District Beijing, PR China 100020 T +86 - 10 65 97 42 25/41 45 F +86 - 10 65 97 42 26 [email protected] China/Shanghai Corus Building Systems Suite 3002, Lt Chengdu North Road Shanghai, PR China 200003 T +86 - 21 63 52 61 22 F +86 - 21 63 60 33 99 [email protected] Hong Kong Corus Building Systems Room 1903, Asia Orient Tower 33 Lockhart Road, Wan Chai Hong Kong T +852 - 28 87 53 41 F +852 - 22 34 67 39 [email protected] Singapore Corus Building Systems Pte Ltd 41 Gul Circle Singapore 629576 T +65 - 67 68 90 81 F +65 - 68 98 93 74 [email protected] www.corus.com.sg Overseas: Australia

Overseas: Middle East Dubai Corus Building Systems P.O. Box 18294 Jebel Ali UAE-Dubai · United Arab Emirates T +971 - 48 87 32 32 F +971 - 48 87 39 77 [email protected]

Australia Corus Building Systems 80/82 Hallam South Road Hallam Victoria · Australia T +61 - 387 95 78 33 F +61 - 387 95 78 44

Kuwait Ali Alghanim & Sons Trading & Contracting Group Co. W.L.L. · P.O. Box 21540 KT-Safat 13076 · Kuwait T +965 - 4 84 22 23 F +965 - 4 84 18 12 The product information and technical details contained in this brochure are accurate, according to our research and technical programme, at the point of going to press. They do not refer to any specific application and cannot give rise to claims for compensation. We reserve the right to make any changes to the construction or product range which seem technically appropriate, in view of our high standards for product advancement and development. Copyright 2004

Corus Bausysteme GmbH · Part of Corus Group plc

adhoc media gmbh:909:GB:04/2005

Europe: