Miretti MeconEX - Miretti srl

16 downloads 289 Views 2MB Size Report
for offshore engines ensures maximum “work-on” time with no unnecessary operational shut- .... Innovation – is at
Explosion Protection for the Oil & Gas industries

MIRETTI S.r.l Sede Commerciale, amministrativa e magazzini: 20812 LIMBIATE (MB) Italia –Via Marconi 29/31 Tel. +39-02/99081.1 – Fax +39-02/99052488

Web pages: http//www.miretti.org

Miretti Oil & Gas: your ideal Partner, able to turn Problems into Solutions

Turning Problems into Solutions with Miretti Oil & Gas Problem - cost of “passively” protecting to Zone 2 diesel engine oilfield equipment with complex control systems and cost of downtime and service maintenance of cleaning exhaust flame traps every 8-20 hours

Solution - Miretti 3GMIR Zone 2 Gas Detection with infrared gas sensing and automatic engine/equipment shutdown

Miretti 3GMIR Zone 2 Gas Detection … Zone 2 Gas Detection for diesel engine oilfield equipment

enables exhaust flame trap elimination

Miretti 3GMIR Zone 2 Gas detection and automatic engine/equipment shut-down system ensures maximum safety and eliminates the need for exhaust flame traps and equipment “down-time” caused when cleaning conventional exhaust flame

Turning problems into solutions with Miretti Oil & Gas Problem - cost of replacing “dry” turbocharger and exhaust manifolds of industrial engines to water-cooled versions as part of Zone 2 conversion process

Solution - Miretti CoatEX a patented process that enables the retention of original OEM engine turbocharger and manifolds

Miretti CoatEX Solutions

Miretti’s patent

Miretti CoatEX enables the OEM “dry” turbocharger and manifold to be retained reducing Zone 2 conversion costs and minimising risk of failure by fitting non OEM turbo and water cooled manifold

Turning problems into Solutions with Miretti Oil & Gas Problem - cost of oilfield equipment “downtime” during operations and the maintenance costs of servicing conventional exhaust flame traps every 8-20 hours

Solution - Miretti FilterEX self cleaning catalytic exhaust flame trap enables up to 1,000 hours operation before inspecting and eventually cleaning and allows oilfield equipment to “work-through” until completion of task

The “Work-through” and “Work-on” solution that enables you to run safe for up to 1.000 hours

Miretti FilterEX

Diesel engines working in classified areas require exhaust flame traps or GD with automatic shutdown to prevent a potential explosion and to comply with ATEX, EN 1834.1.2000, EEMUA 107 and other oil and gas standards.

Miretti FilterEX Solutions Manicooler for low rated engines

Miretti’s patent Exhaust Gas cooler for high rated engines

Miretti FilterEX enables the engine to work for up to 1000 hrs between inspecting intervals and Zone 2 engines to “workthrough” and “work-on” in situations where Gas Detection systems would automatically shut the engine down at 25% LEL

Miretti FilterEX Solutions … for offshore engines ensures maximum “work-on” time with no unnecessary operational shut-downs Miretti FilterEX catalyst based self cleaning exhaust flame traps enable engines/equipment to “work-on” without need for “down-time” as required when replacing/cleaning traditional exhaust flame traps every 8-20 hr (this needs frequent and costly maintenance!)

Turning problems into Solutions with Miretti Oil & Gas Problem – Cost and complexity for modification and compliance of oilfield and engine equipment electrics to different global/regional standards of explosion protection

Solution - Miretti MeecaEX – unified compact engine control system approved worldwide under ATEX, NEC (FM), IECEX, CNEX

Miretti MeecaEX … Zone 2 and FM electronic control system for oilfield equipment enables fast fit and reliable consistent operation

Miretti Meeca.EX Zone 2 electronic controlled system for oilfield equipment ensures simple installation and operation. Certified IECEx/ ATEX Zone 2 and FM to Class 1 Division 2

Miretti MeecaEX Why choose Miretti MeecaEX? compact limited use of EX enclosures approved Worldwide ATEX, NEC (FM), IECEX, CNEX

Turning problems into Solutions with Miretti Oil & Gas Problem – cost of frequent flame arrestor and heat exchanger cleaning maintenance, higher fuel consumption and DPF performance compromised when using “dirty” fuel with high sulphur content

Solution - Miretti MeconEX reduced and normalized flame arrestor maintenance intervals, reduced clogging of exhaust heat exchangers, lower fuel consumption

Miretti MeconEx ...anti-pollution device that save costs by improving efficiency

An environmentally-friendly system which, by improving combustion offers: energy saving reduction of emissions (PM 10 - NOx - HC - CO - CO2 - NO2)

Miretti MeconEx    

very low production of pollutant agents reduction of Carbon Dioxide (CO2) emission high saving of fuel consumption no service stop for flame arrestor cleaning in normal operating conditions  increases the life of Anti-Particulate Filter (DPF)

Turning problems into Solutions with Miretti Oil & Gas Problem - cost of “passive added-safety” for diesel engine and battery electric equipment operating in unclassified areas and risk that equipment continues to operate with explosive atmosphere present

Solution - Miretti GasChecker is a basic kit of parts that can be installed locally to provide gas detection, visual/audible alarms and automatic equipment shutdown at 25% LEL Propane in Air. The system provides for “added-safety” within areas not formally classified

Miretti GasChecker Miretti GasChecker is: compact ergonomic and user-friendly cost effective protection for a multitude of applications

Miretti GasChecker …. “added-safety” Gas detection and automatic shutdown systems available as a kit of parts for local installation

Miretti GasChecker systems are ATEX certified and offer infrared or pellistor based gas detection, visual/audible alarms at 10% LEL and automatic shutdown at 25% LEL. The system has a “forced” gas test to ensure system integrity and can be fitted to most equipment within 1-2 days.

Turning problems into Solutions with Miretti Oil & Gas Problem – availability for rental at short notice ATEX and/or FM compliant material handling equipment for both onshore and offshore applications

Solution - Miretti EXcalibur trucks 4 wheel 48V battery electric counterbalance trucks available on short or long term rental contracts. Miretti also offer to explosion proof all brands of forklift trucks to ATEX or FM requirements

Ex Conversion of OEM trucks or Miretti EXcalibur Zone 1/2 electric trucks for short or long term rental Miretti EXcalibur FM Division 1 or Zone 1 ATEX IIBT4 48V battery electric forklift trucks for on/offshore operation. Available for rental these trucks are simple to operate and to maintain. Options also available for pedestrian pallet, stacker trucks and diesel forklifts

The perfection is made by details (Michelangelo )

Why choose Miretti? Expertise – we have over 40 years experience within the oil and gas, mining and industrial markets

Independence – we serve all brands to enable customers to specify their preferred supplier

Quality – we are ISO 9001 and EN 14001 accredited and our ATEX and Ex systems are approved by all major OEM’s

Global footprint – we have manufacturing and Ex conversion factories in Europe, USA and China and Technical Sales/Service offices throughout Europe

Innovation – is at the heart of our business. We focus on offering

solutions for the problems faced by our customers

Why choose Miretti? Team – our experienced sales, service and technical teams are available to help wherever you are located

Competitive – we offer quality, proven and market leading products and systems at competitive pricing

Certification – our products and systems are independently certified by leading certification authorities including SIRA, INERIS, FM, CNEX, IECEx, TUV

FilterEX – a self cleaning exhaust flame trap that when combined with Miretti exhaust gas coolers can help diesel engine oilfield operators make significant cost saving through reduced ‘downtime’ and service maintenance of flame traps

MIRETTI WORLDWIDE HQ ITALY

USA

FRANCE BRANCH

UK BRANCH

GERMANY BRANCH

SHANGHAI

AUSTRALIA

25

www.miretti.org Head Office – Italy Miretti S.r.l. Via Marconi 29/31 – 20812 Limbiate (MB) Tel +39 02 99081.1 – Fax + 39 02 99052488

[email protected] Miretti UK LTD Office 5 and 7, Premier House 43-45 Sanders Road Finedon Road Industrial Estate Wellingborough NN8 4NL Northamptonshire Tel +44 (0)1933278471

[email protected] Excalibur Miretti – USA 285 Eldridge Road Fairfield New Jersey – 07004 - 2508 Tel: +1 (0)973.57.77.911 – Fax + 1 (0)973.54.50.222

[email protected]