Fully pre-mixed burner. ⢠Modulating gas valve with constant air-to-gas ratio. ⢠Variable-speed combustion fan. â¢
EVERYTHING TO WARM YOU UP BOILERS
SYSTEM COMPONENTS
IMPORTANT
Dear customer, the country codes listed on the left have to be incorporated in the order code whenever ordering our boilers. The letter and number making the country code have to be “copied“ into the code you find in the price list and they replace the two “xx” placed in the code (4th and 5th position). Product code in the price list
Code
CITxx2RU32
→
L2
Your country code
Country
Code
→
Final order code
CITL22RU32
Country
A2
Albania
L4
Lebanon
D2
Algeria
L6
Libyan Arab Jamahiriya
A8
Argentina
M4
Morocco
A0
Armenia
NO
New Zealand
A4
Australia
N4
Norway
A6
Azerbaijan
P4
Palestinian territory
B4
Belarus
K8
Pakistan
B2
Brazil
M0
Republic of Moldova
B0
Bulgaria
R0
Russian Federation
C8
Chile
P6
Saint Pierre and Miquelon
C0
China
S2
Serbia
K4
Colombia
Z0
South Africa
G2
Georgia
H0
Switzerland
U0
Hungary
S4
Syrian Arab Republic
I6
Iraq
T2
Tunisia
Y0
Islamic Republic of Iran
T0
Turkey
G6
Jordan
U2
Ukraine
K0
Kazakhstan
U4
Uruguay
K2
Kyrgyzstan
U6
Uzbekistan
WARM COMFORT
8
GENERAL CONTENTS
S TA N D A R D BOILERS
CONDENSING BOILERS
DOMESTIC WALL-HUNG AND FLOOR STANDING BOILERS
13
WALL-HUNG BOILERS
97
HIGH-CAPACITY BOILERS
67
FLOOR-STANDING BOILERS
143
BURNERS
175
ACCESSORIES
182
H O T WAT E R S T O R A G E S
SYSTEM COMPONENTS
9
185
CONDENSING BOILERS
KIT FOR OUTDOOR INSTALLATION
DOMESTIC WALL-HUNG AND FLOOR STANDING BOILERS
WARM COMFORT
14
Itaca KC
18
Itaca KR
22
Itaca KRB
26
Itaca KB
30
Formentera KC
34
Formentera KR
68
Tahiti Condensing KR 55
38
Formentera KRB
72
Tahiti Condensing KR 85
42
Antea KC
76
Tahiti Condensing Modulo KR
46
Antea KR
86
Maui KR 115-280
50
Antea KRB
92
Maui KR 340-620
54
Giava KRB
58
Madeira Solar Compact KBS
62
Madeira Solar KRBS
10
HIGH- CAPACITY BOILERS
BOILERS STANDARD BOILERS
KIT FOR OUTDOOR INSTALLATION
WALL-HUNG BOILERS
FLOOR-STANDING BOILERS
HOT WATER STORAGES
98
Itaca CTFS
144
Bali B
186
WHPF BM
102
Itaca RTFS
148
Bali RTN - RTN E
188
WHPF BO
106
Formentera CTFS - CTN
150
Bali RTN PVE
190
WHPS BA SS
110
Formentera RTFS - RTN
152
Bali RTN T
192
WHPS PU S
114
Formentera RBTFS
154
Bali RTFS E
194
WHPS BA DS
118
Antea CTFS AF- CTN AF
156
Elba Dual
196
WHPS BL SS
122
Antea CTFS - CTN
158
Rodi Dual 70 ÷ 1300
198
WHPS DX
126
Antea RTFS
162
Rodi Dual 1400 ÷ 3500
130
Antea RBTFS
166
Rodi Dual HR 70 ÷ 1300
134
Panarea Compact CTFS AF - CTN AF
170
Rodi Dual HR 1400 ÷ 3500
138
Nias Dual BTFS
BURNERS
SYSTEM COMPONENTS
176
Pyrós Dual 1G / Pyrós 1G
200
Gemini
178
Pyrós 1 M
203
Accessories
180
Boiler and burner coupling
BOILERS
DOMESTIC WALL-HUNG AND FLOOR STANDING BOILERS
13
CONDENSING BOILERS
CONDENSING
ITACA KC
➲
Modulation range 1:9
➲
Touch screen user interface
➲
HHH efficiency in DHW “comfort” mode
➲
High efficiency pump (ErP ready)
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
User interface to manage three different types of solar thermal systems fitted as standard
Available heat outputs:
12 kW
24 kW
28 kW
Pre-set to run on Methane or Propane
WARM COMFORT
14
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILER, PREMIX BURNER, INSTANT DHW PRODUCTION, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• • • • • • • • • • • • • •
Heat exchanger and pre-mixed burner
Model
ITACA KC 12
ITACA KC 24
ITACA KC 28
ITACA KC 32
Modulating pump
Thermopolymer-covered stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air-to-gas ratio Variable-speed combustion fan Modulating pump with air-purging device 10-liter expansion vessel Stainless steel DHW plate heat exchanger with thermal insulation Ready for connection to a GSM modem for remote switching on and off and malfunction alarm (optional equipment) Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms DHW “Comfort” function: ★★★ Automatic or manual primary circuit filling system Installation flexibility thanks to IPX5D electrical protection degree Energy efficiency marking (92/42/EC): ★★★★ NOx emission class ((EN 297/EN 483): 5
Pre-set for connection to: • external probe • remote control • PCBs for low-temperature zone
Type of gas
Code
Methane
CITxx2CR12
PROPANE
CITxx6CR12
Methane
CITxx2CR24
PROPANE
CITxx6CR24
Methane
CITxx2CR28
PROPANE
CITxx6CR28
Methane
CITxx2CR32
PROPANE
CITxx6CR32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
35.50
24.9
105.1 %
38.00
27.9
105.5 %
39.00
32.3
106.2 %
40.50
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit 15
ITACA KC Dimensions and connection centre distances
Description
Code
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
GSM kit complete with antenna, power supply, interface board, modem
0KITMGSM00
Room temperature probe
0KITSAMB00
Gas and water tap kit
0KITRUBI04
Split pipe kit Ø 80+80
0KITSDOP00
Solar connection kit (for combi boilers)
0KITSOLC07
Connection kit for complex solar systems
0KITSOLC08
Baxi/Itaca replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
121
23 10
31
Article
60 62 67
82
73
750
76
39
100
121
23 10
124
31
63 92 G Gas inlet (½”) 190 M CH flow (¾”) C DHW outlet (½”) F Cold water inlet (½”) R CH return (¾”) S Condensate drain
76
60 62 67
82
73
315
420
63
92
190
G F
31
R
S
121
100
23 10
39
124
M
C
315
76
750
top view
60 62 67
82
73
bottom view 63
190
39
124
ACCESSORIES
92
420
Description 100
Article
Code
315
Coaxial air intake/flue gas outlet for B23 installation type
0ATTCOVE06
Ø 80 flue gas discharge chimney (height 1380 mm)
0camisca00
Beretta/ Itaca replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Immergas/ Itaca replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Pipes and taps cover
0COPETUB03
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Remote control
0CREMOTO04
Ariston/ Itaca replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Fixing template (metal)
0DIMMECO11 Tahiti/ Itaca replacement kit
Wall spacer kit
WARM COMFORT
0DISTANZ00
90° elbow and flange kit Ø 60/100
0KCURFLA00
Ø 100/60 mm coaxial kit
0KITATCO00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE01
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE02
16
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Electric zone kit with external probe
0KITZONE05
External probe
0SONDAES01
Temperature probe for solar heating plants
PSPTMILL00
TECHNICAL SPECIFICATIONS
KC 12
KC 24
KC 28
KC 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
★★★★ 5
★★★★ 5
2.00 ★★★★
2.04 ★★★★
5
5 3.0
Energy efficiency marking (92/42/EC) NOx emission class (EN 297/EN 483) CH maximum working pressure
bar
3.0
3.0
3.0
Maximum CH working temperature
°C
83
83
83
83
CH temperature range
°C
20 - 78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
Consumption at nominal heat output (CH) (80-60°C)
Methane
m3/h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (CH) (80-60°C)
Propane
kg/h
0.93 ★★★
1.84 ★★★
2.05 ★★★
2.36 ★★★
DHW nominal heat output (∆T 30°C)
kW
18.6
27.4
29.2
33.4
DHW minimum heat output (∆T 30°C)
kW
2.0
3.0
3.0
3.9
DHW nominal heat input
kW
18.0
27.3
30.4
34.5 4.2
Energy efficiency marking for DHW production according to EN 13203-1
DHW minimum flow DHW maximum pressure DHW minimum pressure DHW nominal heat output (∆T 30°C) DHW maximum working temperature DHW temperature range Consumption at nominal heat output (DHW) Consumption at nominal heat output (DHW) Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 content at nominal heat input CO2 content at nominal heat input Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure Supply pressure Power supply voltage/frequency Fuse on the power supply Power absorption Electric protection rating Gas fitting CH fittings DHW fittings LxHxD Net weight Gross weight
kW
2.0
3.0
3.3
bar
6.0
6.0
6.0
6.0
bar
0.5
0.5
0.5
0.5
l/min °C
8.8 62
13.4 62
15.5 62
16.2 62
°C
35 - 37
35 - 57
35 - 57
35 - 57
Methane
m3/h
1.90
2.89
3.22
3.65
Propane
kg/h
1.40
2.12
2.36
2.68
°C
57.9
61.0
60.0
60.0
°C
34.5
33.0
45.0
40.5
g/s
8.25
12.43
13.93
15.81 1.87
g/s
0.89
1.33
1.47
Methane
%
9.0
9.0
9.0
9.0
Propane
%
10.0
10.0
10.0
10.0
Pa
114
130
170
183
Pa
1.4
1.6
2.0
3.5
Methane
mbar
20
20
20
20
Propane
mbar
37
37
37
37
V/Hz
230/50
230/50
230/50
230/50
A
3.15
3.15
3.15
3.15
W
121
121
121
121
IPX5D
IPX5D
IPX5D
IPX5D
G½
G½
G½
G½
G¾
G¾
G¾
G¾
G½
G½
G½
G½
mm
17
420x750x315
kg
32.00
34.50
35.50
37.00
kg
35.50
38.00
39.00
40.50
CONDENSING BOILERS
WALL-HUNG CONDENSING COMBI BOILERS
ITACA KR
➲
Modulation ratio: 1:9
➲
Touch screen user interface
➲
High efficiency pump (ErP ready)
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Time control of hot water storage regeneration
Available with the following outputs:
12 kW
24 kW
28 kW
Pre-set to run on Methane or Propane
WARM COMFORT
18
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILER, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermosetting polymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air/gas ratio • Variable-speed combustion fan • Modulating pump with built-in air purging device • 10-litre expansion vessel • Presetting for connection to GSM modem for switching on and off and remote display of faults (optional) • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Flexible installation thanks to IPX5D electrical protection degree • Efficiency rating according to 92/42/EC: ★★★★ • NOx emission class (EN 297): 5 Ready for connection to: • external probe • Remote Control • PCBs for low-temperature zones Heat exchanger and pre-mixed burner
Model
ITACA KR 12 ITACA KR 24 ITACA KR 28 ITACA KR 32
Modulating pump
Type of gas
Code
METHANE
CITxx2RR12
PROPANE
CITxx6RR12
METHANE
CITxx2RR24
PROPANE
CITxx6RR24
METHANE
CITxx2RR28
PROPANE
CITxx6RR28
METHANE
CITxx2RR32
PROPANE
CITxx6RR32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
34.00
24.9
105.1 %
35.50
27.9
105.5 %
37.00
32.3
106.2 %
38.50
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit 19
ITACA KR Article
Description
Code
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE02
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
GSM kit complete with antenna, power supply, interface board, modem
0KITMGSM00
Room temperature probe
0KITSAMB00
Gas and water tap kit
0KITRUBI04
Split pipe kit Ø 80+80
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Baxi/Itaca replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
121
23 10
31
Dimensions and connection centre distances
60 62 67
82
73
750
76
63
92
190
100
39
124
G Gas inlet (½”) M CH system flow (¾”) F Cold water inlet (½”) R CH system return (¾”) SI Condensate drain RS Boiler drain cock
315
420
top view bottom view
ACCESSORIES Article
Description
Code
Coaxial air intake/flue gas outlet for B23 installation type
0ATTCOVE06
Beretta/ Itaca replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Ø 80 flue gas discharge chimney (height 1380 mm)
0camisca00
Immergas/ Itaca replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Pipes and taps cover
0COPETUB03
Ariston/ Itaca replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Remote control
0CREMOTO04 Tahiti/ Itaca replacement kit
Fixing template (metal)
Wall spacer kit
WARM COMFORT
0DIMMECO11
0DISTANZ00
90° elbow and flange kit Ø 60/100
0KCURFLA00
Ø 100/60 mm coaxial kit
0KITATCO00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE01
20
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Electric zone kit with external probe
0KITZONE05
External probe
0SONDAES01
Temperature probe for solar heating plants
PSPTMILL00
TECHNICAL SPECIFICATIONS
KR 12
KR 24
KR 28
KR 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
Efficiency rating according to 92/42/EC NOx class (EN 297/EN 483) Maximum working pressure
bar
1.92
2.09
2.00
2.04
★★★★
★★★★
★★★★
★★★★
5
5
5
5
3.0
3.0
3.0
3.0
Maximum working temperature
°C
83
83
83
83
Temperature setting range
°C
20 - 78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
3
Consumption at nominal heat output (CH) (80-60°C)
Methane
m /h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (CH) (80-60°C)
Propane
kg/h
0.93
1.84
2.05
2.36
DHW maximum working temperature
°C
65
65
65
65
DHW temperature range
°C
36-65
36-65
36-35
36-35
Air-flue ΔT at nominal heat input
°C
57.9
61.0
60.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
40.5
Flue gas flow at nominal heat input
g/s
8.25
12.43
13.93
15.81
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
1.87
CO2 content at nominal heat input
Methane
%
9.0
9.0
9.0
9.0
CO2 content at nominal heat input
Propane
%
10.0
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
183
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
3.5
Supply pressure
Methane
mbar
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
V / Hz
230/50
230/50
230/50
230/50
Power mains supply fuse
Power supply voltage/frequency
A
3.15
3.15
3.15
3.15
Power absorption
W
121
121
121
121
IPX5D
IPX5D
IPX5D
IPX5D
Electric protection rating Gas fitting
G½
G½
G½
G½
CH fittings
G¾
G¾
G¾
G¾
Hot water storage fittings
G½
G½
G½
G½
WxHxD
mm
420x750x315
Net weight
kg
30.50
32.00
33.50
35.00
Gross weight
kg
34.00
35.50
37.00
38.50
21
CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS
ITACA KRB
➲
Modulation ratio: 1:9
➲
Touch screen user interface
➲
High efficiency pump (ErP ready)
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Time control of hot water storage regeneration
Available with the following outputs:
12 kW
24 kW
28 kW
Hot water storage temperature probe included
Pre-set to run on Methane or Propane
WARM COMFORT
22
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER, INTEGRATED THREE-WAY VALVE, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• • • • • • • • • • • •
Heat exchanger and pre-mixed burner
Model
ITACA KRB 12 ITACA KRB 24 ITACA KRB 28 ITACA KRB 32
Integrated 3-way deviating valve Thermosetting polymer-covered stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air/gas ratio Variable-speed combustion fan Modulating pump with built-in air purging device 10-litre expansion vessel Presetting for connection to GSM modem for switching on and off and remote display of faults (optional) Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms Installation flexibility thanks to IPX5D electrical protection degree Efficiency rating according to 92/42/EC: ★★★★ NOx emission class (EN 297/EN 483): 5
Ready for connection to: • external probe • remote control • PCBs for low-temperature zones • hot water storage probe
Modulating pump
Type of gas
Code
METHANE
CITxx2RU12
PROPANE
CITxx6RU12
METHANE
CITxx2RU24
PROPANE
CITxx6RU24
METHANE
CITxx2RU28
PROPANE
CITxx6RU28
METHANE
CITxx2RU32
PROPANE
CITxx6RU32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
36.50
24.9
105.1 %
37.00
27.9
105.5 %
38.50
32.3
106.2 %
40.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit 23
ITACA KRB Dimensions and connection centre distances
Description
Code
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE02
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
GSM kit complete with antenna, power supply, interface board, modem
0KITMGSM00
Gas and water tap kit
0KITRUBI04
Room temperature probe
0KITSAMB00
Split pipe kit Ø 80+80
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Baxi/Itaca replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Itaca replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Immergas/ Itaca replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Itaca replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
82
73
100
39
124
750
121
23 10
31
G Gas inlet (½”) M CH system flow (¾”) MB Flow to hot 60 62 67 water76storage (½”) RS Boiler drain cock RB Return from hot190 63 92 water storage (½”) R CH system return (¾”) SI Condensate drain
Article
315
420
bottom view
top view
ACCESSORIES Article
Description
Code
Coaxial air intake/flue gas outlet for B23 installation type
0ATTCOVE06
Ø 80 flue gas discharge chimney (height 1380 mm)
0camisca00
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Pipes and taps cover
0COPETUB03
Remote control
0CREMOTO04 Tahiti/ Itaca replacement kit
Fixing template (metal)
Wall spacer ki
WARM COMFORT
0DIMMECO11
0DISTANZ00
90° elbow and flange kit Ø 60/100
0KCURFLA00
Ø 100/60 mm coaxial kit
0KITATCO00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE01
24
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Electric zone kit with external probe
0KITZONE05
External probe
0SONDAES01
Temperature probe for solar heating plants
PSPTMILL00
TECHNICAL SPECIFICATIONS
KRB 12
KRB 24
KRB 28
KRB 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
Efficiency rating according to 92/42/EC NOx class (EN 297/EN 483) Maximum working pressure
bar
1.92
2.09
2.00
2.04
★★★★
★★★★
★★★★
★★★★
5
5
5
5
3.0
3.0
3.0
3.0
Maximum working temperature
°C
83
83
83
83
Temperature setting range
°C
20 - 78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
3
Consumption at nominal heat output (CH) (80-60°C)
Methane
m /h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (CH) (80-60°C)
Propane
kg/h
0.93
1.84
2.05
2.36
DHW maximum working temperature
°C
65
65
65
65
DHW temperature range
°C
36-65
36-65
36-35
36-35
Air-flue ΔT at nominal heat input
°C
57.9
61.0
60.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
40.5
Flue gas flow at nominal heat input
g/s
8.25
12.43
13.93
15.81
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
1.87
CO2 content at nominal heat input
Methane
%
9.0
9.0
9.0
9.0
CO2 content at nominal heat input
Propane
%
10.0
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
183
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
3.5
Supply pressure
Methane
mbar
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
V / Hz
230/50
230/50
230/50
230/50
Power mains supply fuse
Power supply voltage/frequency
A
3.15
3.15
3.15
3.15
Power absorption
W
121
121
121
121
IPX5D
IPX5D
IPX5D
IPX5D
Electric protection rating Gas fitting
G½
G½
G½
G½
CH fittings
G¾
G¾
G¾
G¾
Hot water storage fittings
G½
G½
G½
G½
WxHxD
mm
420x750x315
Net weight
kg
32.00
32.50
34.00
35.50
Gross weight
kg
36.50
37.00
38.50
40.00
25
CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS with 3-way valve
ITACA KB
➲
Modulation ratio: 1:9
➲
Touch screen user interface
➲
45-lt. stainless steel hot water storage
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Can be connected to a DHW recirculation system
➲
Time control of hot water storage regeneration
Available heat outputs:
24 kW
32 kW
Pre-set to run on Methane or Propane
WARM COMFORT
26
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, INTEGRATED DHW STORAGE, SEALED COMBUSTION CHAMBER
• • • • • • • • •
Thermopolymer-covered stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air-to-gas ratio Variable-speed combustion fan 3-speed pump with integrated air purging deviceo 10-litre expansion vessel 2-lt. DHW expansion vessel 45-lt. stainless steel insulated hot water storage Ready for connection to a GSM modem for remote switching on and off and malfunction alarm (optional equipment) • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Energy efficiency marking (92/42/EC ★★★★) • NOx emission class (EN 297)
Heat exchanger and pre-mixed burner
Model
ITACA KB 24 ITACA KB 32
Stainless steel hot water storage
Ready for connection to: • external probe, • remote control, • PCBs for low-temperature zones.
Type of gas
Code
METHANE
CITxx2BR24
PROPANE
CITxx6BR24
METHANE
CITxx2BR32
PROPANE
CITxx6BR32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
25.0
105.4 %
74.00
32.2
105.8 %
79.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit
27
ITACA KB Article
Dimensions and connection centre distances
Description
Code
580
34
G M
F
Sludge remover 153
RI 861
M
136 45
153
40 70
136
129 50
61 88
136
129 50
0KITDEFA00
38
Flow - return cold water 90° taps kit
0KITIDBA11
GSM kit complete with antenna, power supply, interface board, modem
0KITMGSM00
Gas and water tap kit
0KITRUBI01
Room temperature probe (extensible up to 100 m)
0KITSAMB00
Split kit Ø 80+80
0KITSDOP00
Electric kit for management of different temperature zones (with external probe)
0KITZONE05
Kit recirculation for ITACA KB
0KRICIRC02
External probe
0SONDAES01
38
145
143
40 70
0KITATCO00 RI
C 136 45
R
195
G
195
R Ø 60/100 F mmC coaxial kit
402
61 88
145
143
G Gas inlet (½”) M CH flow (¾”) C DHW outlet (½”) F Cold water inlet (½”) R CH return (¾”) RI Recirculation inlet (½”) top view G
R
F
C RI
153
136 45
195
M
40 70
136
129 50
38
bottom view 61 88
143
ACCESSORIES Article
145
402
WARM COMFORT
Description
Code
Ø 60/100 mm, metre long type “A” coaxial kit
0CONDASP00
Pipes and taps cover
0COPETUB05
Remote Control
0CREMOTO04
90° elbow and flange kit Ø 60/100
0KCURFLA00
28
TECHNICAL SPECIFICATIONS Nominal heat input
kW
Nominal heat output (80-60°C) Nominal heat output (50-30°C) Minimum heat output (80-60°C) Minimum heat output (50-30°C) Useful efficiency at nominal heat input (80-60°C) Useful efficiency at minimum heat input (80-60°C) Useful efficiency at nominal heat input (50-30°C) Useful efficiency at minimum heat input (50-30°C) Useful efficiency at 30% Casing heat loss with burner on at nominal heat input Casing heat loss with burner on at minimum heat input Casing heat loss with burner off Chimney heat loss with burner on at nominal heat input Chimney heat loss with burner on at minimum heat input Efficiency marking (92/42/EC) NOx class (EN 297/EN 483) CH maximum working pressure CH maximum working temperature CH temperature range CH expansion vessel capacity Consumption at nominal heat output (CH) (80-60°C) Consumption at nominal heat output (CH) (80-60°C) DHW nominal heat output (∆T 30°C) DHW minimum heat output (∆T 30°C) DHW nominal heat output DHW minimum heat output DHW useful efficiency at nominal heat input (∆T 30°C) DHW maximum pressure DHW minimum pressure DHW nominal flow at ∆T 30°C DHW nominal flow at ΔT 25 °C DHW maximum working temperature DHW temperature range DHW expansion vessel capacity Consumption at nominal heat output (DHW) Consumption at nominal heat output (DHW) Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 at nominal heat input CO2 at nominal heat input Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure Supply pressure Power supply voltage/frequency Fuse on the power supply Power absorption Electric protection rating Gas fitting CH fittings DHW fittings LxHxD Net weight Gross weight Boiler
kW kW kW kW % % % % % % % % % %
Methane Propane
Methane Propane
Methane Propane
Methane Propane
bar °C °C l m3/h kg/h kW kW kW kW % bar bar l/min l/min °C °C l m3/h kg/h °C °C g/s g/s % % Pa Pa mbar mbar V/Hz A W
mm kg kg
29
KB 24
KB 32
23.7 22.8 25.0 2.7 3.2 96.2 91.4 105.4 105.4 106.9 0.97 6.49 0.28 2.62 2.09 ★★★★ 5 3.0 83 20 - 78 10 2.51 1.84 26.8 2.7 27.3 3.0 98.2 6.0 0.5 16.2 19.4 65 35 - 65 2 2.89 2.12 61 33 12.43 1.33 9.0 10.0 130 1.56 20 37 230/50 3.15 116 IPX4D G½ G¾ G½
30.4 29.4 32.2 3.9 4.4 96.6 92.1 105.8 105.1 107.3 0.99 5.06 0.22 2.61 2.04 ★★★★ 5 3.0 83 20 - 78 10 3.22 2.36 33.4 3.9 34.5 4.2 96.8 6.0 0.5 19.5 23.4 65 35 - 65 2 3.65 2.68 60 40.5 15.81 1.87 9.0 10.0 183 3.5 20 37 230/50 3.15 121 IPX4D G½ G¾ G½ 580x861x402
61.50 74.00
66.50 79.00
CONDENSING BOILERS
Wall-hung condensing boiler with an integrated hot water storage
FORMENTERA KC
➲
Modulation range 1:9
➲
Touch screen user interface
➲
User interface to manage three different types of solar thermal systems fitted as standard (solar probes optional)
➲
Ready for connection to external probe
➲
26-plate DHW heat exchanger
Available heat outputs:
12 kW
24 kW
28 kW
Pre-set to run on Methane or Propane
WARM COMFORT
30
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, INSTANT DHW PRODUCTION, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermopolymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air-to-gas ratio • Variable-speed combustion fan • 3-speed pump with integrated air purging device • 10-litre expansion vessel • Plate stainless steel DHW heat exchanger • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Boiler hydraulic replacement kit available as optional equipment • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297): 5 Ready for connection to: • external probe • remote control Heat exchanger and pre-mixed burner
26-plate DHW heat exchanger
Model
FORMENTERA KC 12 FORMENTERA KC 24 FORMENTERA KC 28 FORMENTERA KC 32
• PCBs for low-temperature zones
Type of gas
Code
METHANE
CFOxx2CR12
PROPANE
CFOxx6CR12
METHANE
CFOxx2CR24
PROPANE
CFOxx6CR24
METHANE
CFOxx2CR28
PROPANE
CFOxx6CR28
METHANE
CFOxx2CR32
PROPANE
CFOxx6CR32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
36.50
24.9
105.1 %
37.50
27.9
105.5 %
39.00
32.3
106.2 %
40.50
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit
31
FORMENTERA KC Article
Description
Code
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE02
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Gas and water tap kit
0KITRUBI04
Split pipe kit Ø 80+80
0KITSDOP00
Solar connection kit (for combi boilers)
0KITSOLC07
Connection kit for complex solar systems
0KITSOLC08
0ATTCOVE06
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
0camisca00
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Immergas/ Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Pipes and taps cover
0COPETUB03
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Remote control
0CREMOTO04
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Fixing template (metal)
0DIMMECO11
Tahiti/ Formentera replacement kit
0KITSOST13
Wall spacer ki
0DISTANZ00
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
90° elbow and flange kit Ø 60/100
0KCURFLA00
Electric zone kit with external probe
0KITZONE05
Ø 100/60 mm coaxial kit
0KITATCO00
External probe
0SONDAES01
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE01
Temperature probe for solar heating plants
PSPTMILL00
Dimensions and connection centre distances
23 10 121
31
100
420
750
76 60 62 67 92
82
73
190
G 76 60 62 67
82
73
315
190 92 bottom view
top view
100
124
63
39
420
39
31
R
100
F
124
C
23 10 121
S
73
315
63
M
82
39
124
750
23 10 121
31
G Gas inlet (½”) M CH flow (¾”) C DHW outlet (½”) 60 62 67 F Cold water76 inlet 190 63 92 (½”) R CH return (¾”) S Condensate drain
ACCESSORIES 315
Article
Description Coaxial air intake/flue gas outlet for B23 installation type
Ø 80 flue gas discharge chimney (height 1380 mm)
WARM COMFORT
Code
32
TECHNICAL SPECIFICATIONS
KC 12
KC 24
KC 28
KC 32
Nominal heat input
kW
Nominal heat output (80-60°C)
kW
12.0 11.6
23.7 22.9
26.4 25.4
30.4 29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.22
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
2.00
2.04
★★★★
★★★★
★★★★
★★★★
Energy efficiency marking (92/42/EC) NOx emission class (EN 297/EN 483)
5
5
5
5
3.0
3.0
3.0
3.0
CH maximum working pressure
bar
Maximum CH working temperature
°C
83
83
83
83
CH temperature range
°C
20-78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
Consumption at nominal heat output (CH) (80-60°C)
Methane
m3/h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (CH) (80-60°C)
Propane
kg/h
0.93
1.84
2.05
2.36
DHW nominal heat output (∆T 30°C)
kW
18.4
27.4
29.2
33.4
DHW minimum heat output (∆T 30°C)
kW
2.0
3.0
3.0
3.9
DHW nominal heat input
kW
18.0
27.3
30.4
34.5
DHW minimum flow DHW maximum pressure DHW minimum pressure DHW nominal heat output (∆T 30°C) DHW maximum working temperature DHW temperature range Consumption at nominal heat output (DHW) Consumption at nominal heat output (DHW) Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 content at nominal heat input CO2 content at nominal heat input Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure Supply pressure Power supply voltage/frequency Fuse on the power supply Power absorption Electric protection rating Gas fitting CH fittings DHW fittings LxHxD Net weight Gross weight
kW
2.0
3.0
3.3
4.2
bar
6.0
6.0
6.0
6.0
bar
0.5
0.5
0.5
0.5
l/min
8.6
13.4
15.5
16.2
°C
62
62
62
62
°C
35-57
35 - 57
35 - 57
35 - 57
Methane
m3/h
2.89
3.22
3.65
Propane
kg/h
1.90 1.40
2.12
2.36
2.68
61.0
60.0
60.0
°C
57.9 34.5
33.0
45.0
40.5
g/s
8.25
12.43
13.93
15.81
g/s
0.89
1.33
1.47
1.87
Methane
%
9.0
9.0
9.0
9.0
Propane
%
10.0
10.0
10.0
10.0
Pa
114
130
170
183
Pa
1.4
1.6
2.0
3.5
Methane
mbar
20
20
20
20
Propane
mbar
37
37
37
37
V/Hz
230/50
230/50
230/50
230/50
A
3.15
3.15
3.15
3.15
W
131
151
151
151
IPX5D
IPX5D
IPX5D
IPX5D
G½
G½
G½
G½
G¾
G¾
G¾
G¾
G½
G½
G½
G½
°C
mm
33
420x750x315
kg
32.50
33.50
35.00
35.50
kg
36.50
37.50
39.00
40.50
CONDENSING BOILERS
WALL-HUNG CONDENSING COMBI BOILERS
FORMENTERA KR
➲
Modulation range 1:9
➲
Touch screen user interface
➲
Ready for connection with external probe
➲
User interface to manage a solar thermal systems fitted as standard (solar probes optional)
Available heat outputs:
12 kW
24 kW
28 kW
Pre-set to run on Methane or Propane
WARM COMFORT
34
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BESUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermopolymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air-to-gas ratio • Variable-speed combustion fan • 3-speed pump with integrated air purging device • 10-litre expansion vessel • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Boiler hydraulic replacement kit available as optional equipment • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297): 5 Ready for connection to: Heat exchanger and pre-mixed burner
Model
FORMENTERA KR 12 FORMENTERA KR 24 FORMENTERA KR 28 FORMENTERA KR 32
• external probe • remote control • PCBs for low-temperature zones
Type of gas
Code
METHANE
CFOxx2RR12
PROPANE
CFOxx6RR12
METHANE
CFOxx2RR24
PROPANE
CFOxx6RR24
METHANE
CFOxx2RR28
PROPANE
CFOxx6RR28
METHANE
CFOxx2RR32
PROPANE
CFOxx6RR32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
34.00
24.9
105.1 %
36.00
27.9
105.5 %
37.50
32.3
106.2 %
39.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit
35
FORMENTERA KR Dimensions and connection centre distances
Description
Code
Ø 100/60 mm coaxial kit
0KITATCO00
750
750
23 10 121
31
Article
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers 76 60 62 67 82 73 63
92
190
315
39
0KITCOPE02
Sludge remover
0KITDEFA00
Gas and water tap kit
0KITRUBI04
Split pipe kit Ø 80+80
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
315 63 92
M
100 124
R
121
10
154 31
F
190 39
420
S
100
124
ProtProtection kit for outdoor installation, for condensing boilers
420
0KITCOPE01
G
76 122 67 82 73
bottom view
top view
G Gas inlet (½”) M CH flow (¾”) F Cold water inlet (½”)
R CH return (¾”) S Condensate drain
ACCESSORIES Article
WARM COMFORT
Description
Code
Coaxial air intake/flue gas outlet for B23 installation type
0ATTCOVE06
Immergas/Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Ø 80 flue gas discharge chimney (height 1380 mm)
0camisca00
Vaillant/ Formentera replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Pipes and taps cover
0COPETUB03
Tahiti/ Formentera replacement kit
0KITSOST13
Remote control
0CREMOTO04
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Fixing template (metal)
0DIMMECO11
Electric zone kit with external probe
0KITZONE05
Wall spacer ki
0DISTANZ00
External probe
0SONDAES01
90° elbow and flange kit Ø 60/100
0KCURFLA00
Temperature probe for solar heating plants
PSPTMILL00
36
TECHNICAL SPECIFICATIONS
KR 12
KR 24
KR 28
KR 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
2.00
2.04
Energy efficiency marking (92/42/EC)
★★★★
★★★★
★★★★
★★★★
NOx emission class (EN 297/EN 483)
5
5
5
5
3.0
3.0
3.0
3.0
CH maximum working pressure
bar
Maximum CH working temperature
°C
83
83
83
83
CH temperature range
°C
20 - 78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
3
Consumption at nominal heat output (80-60°C)
Methane
m /h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (80-60°C)
Propane
kg/h
0.93
1.84
2.05
2.36
Air-flue ΔT at nominal heat input
°C
57.9
61.0
60.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
40.5
DHW maximum working temperature
°C
65
65
65
65
DHW temperature range
°C
36-65
36-65
36-65
36-65
Flue gas flow at nominal heat input
g/s
8.25
12.43
13.93
15.81
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
1.87
CO2 content at nominal heat input
Methane
%
9.0
9.0
9.0
9.0
CO2 content at nominal heat input
Propane
%
10.0
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
183
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
3.5
Supply pressure
Methane
mbar
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
Power supply voltage/frequency
V/Hz
230/50
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
3.15
Power absorption
W
131
151
151
151
IPX5D
IPX5D
IPX5D
IPX5D
Gas fitting
G½
G½
G½
G½
CH fittings
G¾
G¾
G¾
G¾
DHW fittings
G½
G½
G½
G½
Electric protection rating
LxHxD
mm
420x750x315
Net weight
kg
30.00
32.00
33.50
35.00
Gross weight
kg
34.00
36.00
37.50
39.00
37
CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS
FORMENTERA KRB
➲
Modulation range 1:9
➲
Touch screen user interface
➲
Ready for connection with external probe
➲
User interface to manage a solar thermal systems fitted as standard (solar probes optional)
Available heat outputs:
12 kW
24 kW
28 kW
Pre-set to run on Methane or Propane
WARM COMFORT
38
32 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER, INTEGRATED THREE-WAY VALVE, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• • • • • • • • •
Integrated 3-way deviating valve Thermopolymer-covered stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air-to-gas ratio Variable-speed combustion fan 3-speed pump with integrated air purging device 10-litre expansion vessel Installation flexibility thanks to IPX5D electrical protection degree Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Boiler hydraulic replacement kit available as optional equipment • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297): 5 Ready for connection to: • external probe • remote control • PCBs for low-temperature zones
Heat exchanger and pre-mixed burner
Hot water storage temperature probe included
Model
FORMENTERA KRB 12 FORMENTERA KRB 24 FORMENTERA KRB 28 FORMENTERA KRB 32
Type of gas
Code
METHANE
CFOxx2RU12
PROPANE
CFOxx6RU12
METHANE
CFOxx2RU24
PROPANE
CFOxx6RU24
METHANE
CFOxx2RU28
PROPANE
CFOxx6RU28
METHANE
CFOxx2RU32
PROPANE
CFOxx6RU32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
35.50
24.9
105.1 %
37.00
27.9
105.5 %
38.00
32.3
106.2 %
39.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, air-intake blanking tap kit, wall fixing kit
39
FORMENTERA KRB Article
Description
Code
Ø 100/60 mm coaxial kit
0KITATCO00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE01
23 10 121
31
Dimensions and connection centre distances
124 100 420
92
82
73
190ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE02
39
63
750
750
76 60 62 67
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Gas and water tap kit
0KITRUBI01
Split pipe kit Ø 80+80
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
315
420
315 63 92
190
100 124
R
121
10
154 31
S
RB
76 60 62 67 82 73
bottom view G Gas inlet (½”) M CH flow (¾”) MB Flow to the water tank
39
MB M
G
top view
RB Return from the water tank R CH return (¾”) S Condensate drain
ACCESSORIES Article
WARM COMFORT
Description
Code
Coaxial air intake/flue gas outlet for B23 installation type
0ATTCOVE06
Immergas/ Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Ø 80 flue gas discharge chimney (height 1380 mm)
0camisca00
Vaillant/ Formentera replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Pipes and taps cover
0COPETUB03
Tahiti/ Formentera replacement kit
0KITSOST13
Remote control
0CREMOTO04
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Fixing template (metal)
0DIMMECO11
Electric zone kit with external probe
0KITZONE05
Wall spacer ki
0DISTANZ00
External probe
0SONDAES01
90° elbow and flange kit Ø 60/100
0KCURFLA00
Temperature probe for solar heating plants
PSPTMILL00
40
TECHNICAL SPECIFICATIONS
KRB 12
KRB 24
KRB 28
KRB 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
29.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
32.3
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30°C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
104.8
Useful efficiency at 30%
%
106.0
106.5
107.0
108.3
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
2.00
2.04
Energy efficiency marking (92/42/EC)
★★★★
★★★★
★★★★
★★★★
NOx emission class (EN 297/EN 483)
5
5
5
5
3.0
3.0
3.0
3.0
CH maximum working pressure
bar
Maximum CH working temperature
°C
83
83
83
83
CH temperature range
°C
20 - 78
20 - 78
20 - 78
20 - 78
Expansion vessel capacity
l
10
10
10
10
3
Consumption at nominal heat output (80-60°C)
Methane
m /h
1.27
2.51
2.79
3.22
Consumption at nominal heat output (80-60°C)
Propane
kg/h
0.93
1.84
2.05
2.36
Air-flue ΔT at nominal heat input
°C
57.9
61.0
60.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
40.5
DHW maximum working temperature
°C
65
65
65
65
DHW temperature range
°C
36-65
36-65
36-65
36-65
Flue gas flow at nominal heat input
g/s
8.25
12.43
13.93
15.81
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
1.87
CO2 content at nominal heat input
Methane
%
9.0
9.0
9.0
9.0
CO2 content at nominal heat input
Propane
%
10.0
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
183
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
3.5
Supply pressure
Methane
mbar
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
Power supply voltage/frequency
V/Hz
230/50
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
3.15
Power absorption
W
131
151
151
151
IPX5D
IPX5D
IPX5D
IPX5D
Gas fitting
G½
G½
G½
G½
CH fittings
G¾
G¾
G¾
G¾
DHW fittings
G½
G½
G½
G½
Electric protection rating
LxHxD
mm
420x750x315
Net weight
kg
31.50
33.00
34.00
35.00
Gross weight
kg
35.50
37.00
38.00
39.00
41
CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS with 3-way valve
ANTEA KC
➲
Ultra-compact
➲
Modulation range 1:9
➲
LCD user interface
➲
Ready for connection with external probe (optional)
➲
Additional relay managing 2 heating zones
➲
Expansion vessel 9 lt.
➲
Boiler hydraulic replacement kit Available heat outputs:
12 kW
24 kW
Pre-set to run on Methane or Propane
WARM COMFORT
42
28 kW
CONDENSING BOILERS
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, INSTANT DHW PRODUCTION, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermopolymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air-to-gas ratio • Variable-speed combustion fan • 3-speed pump with integrated air purging device • Flame modulation in heating and DHW modes • Wide modulation range 1:9 • Possible connection of additional complex zones and heat pumps • Low power consumption in stand-by in accordance with EuP Directive • Multifunctional relay for alarms or simple zones • Electronic ignition, flame detection via ionization • NTC temperature probes for central heating and DHW • LCD interface with diagnostics • By-pass fitted as standard • Plate stainless steel DHW heat exchanger
Wall-hung condensing boiler with premix burner, instantaneous production of hot water, sealed chamber. Available with heat output of 12.6, 24.9 and 27.9 kW (50°C - 30°C). Pre-set to run on Methane or Propane.
Model
ANTEA KC 12
ANTEA KC 24
ANTEA KC 28
• Motorised diverter valve • Ready for connection to: external probe, remote control, PCB for low-temperature zone, PCB for solar system • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297): 5 Type of gas
Code
METHANE
CAOxx2CR12
PROPANE
CAOxx6CR12
METHANE
CAOxx2CR24
PROPANE
CAOxx6CR24
METHANE
CAOxx2CR28
PROPANE
CAOxx6CR28
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
30.50
24.9
105.1 %
32.00
27.9
105.5 %
33.50
THE PRICE INCLUDES: Paper template, dowels, air-intake blanking cap for air intake opening.
43
ANTEA KC Article
Dimensions and connection centre distances
Description
Code
Flow - return cold water 90° taps kit
0KITIDBA11
245
Base hydraulic kit (copper pipes and straight cocks)
0KITIDBA13
“Plus” hydraulic kit (copper pipes, square cocks and bicones)
0KITIDBA14
700
700
700
52
126
152,5
G
C 31
R
400
250
F
60
62
66
67
60
62 82
67 63
126 52
63
bottom view G Gas inlet (½”) M CH flow (¾”) C DHW outlet (½”) SV Safety valve drain cock
top view F Cold water inlet (½”) R CH return (¾”) S Condensate drain
ACCESSORIES Article
WARM COMFORT
62
67
82
Split pipe kit Ø 80+80
0KITSDOP00
Kit for connection to solar plant with deviating valve and thermostatic mixing valve
0KITSOLC04
Connection kit for complex solar systems
0KITSOLC08
Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
91
0KITRUBI04
63
91
91
82
Gas and water tap kit
152,5
R 81
31
81
66
245
245 152,5
R
60
66
126
FG
114
31
M S
114
M S
SV G
C SV
C
250
250
400
52
400
81
114
M S
F
Description
Code
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Pipes and taps cover
0COPETUB00
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Remote control
0CREMOTO04
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
Fixing template (metal)
0DIMMECO10
Replacement kit Tahiti/Antea
0KITSOST07
Wall spacer ki
0DISTANZ00
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
90° elbow and flange kit Ø 60/100
0KCURFLA00
Electric zone kit with external probe
0KITZONE05
Ø 100/60 mm coaxial kit
0KITATCO00
External probe
0SONDAES01
Sludge remover
0KITDEFA00
Temperature probe for solar heating plants
PSPTMILL00
44
TECHNICAL SPECIFICATIONS
KC 12
KC 24
KC 28
Nominal heat input
kW
12.0
23.7
26.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
Minimal heat output (80-60°C)
kW
1.8
2.7
3.0
Minimal heat output (50-30°C)
kW
2.1
3.2
3.5
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
Useful efficiency at minimal heat input (80-60°C)
%
90.3
91.4
92.3
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
Useful efficiency at minimal heat input (50-30°C)
%
105.0
104.9
104.5
Useful efficiency at 30%
%
106.0
106.5
107.0
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
Casing heat loss with burner off
%
0.55
0.28
0.25
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
2.00
★★★★
★★★★
★★★★
Energy efficiency marking (92/42/EC) NOx class (EN 297/EN 483)
5
5
5
3.0
3.0
3.0
CH maximum working pressure
bar
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
20-78
20-78
20-78
Expansion vessel capacity
l
9
9
9
Consumption at nominal heat output (CH) (80-60°C)
Methane
m3/h
1.27
2.51
2.79
Consumption at nominal heat output (CH) (80-60°C)
Propane
kg/h
0.93
1.84
2.05
DHW nominal heat output (∆T 30°C)
kW
18.4
27.4
29.2
DHW minimal heat output (∆T 30°C)
kW
2.0
3.0
3.0
DHW nominal heat input
kW
18.0
27.3
30.4
DHW minimum heat input
kW
2.0
3.0
3.3
DHW maximum pressure
bar
6.0
6.0
6.0
bar
0.5
0.5
0.5
l/min
8.6
13.4
15.0
DHW minimum pressure DHW nominal flow ∆T 30°C DHW maximum working temperature
°C
62
62
62
DHW temperature range
°C
35-57
35-57
35-57
Consumption at nominal heat output (DHW)
Methane
m3/h
1.90
2.89
3.22
Consumption at nominal heat output (DHW)
Propane
kg/h
1.40
2.12
2.36
°C
57.9
61.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
Flue gas flow at nominal heat input (CH and DHW)
g/s
8.25
12.43
13.93 1.47
Air-flue ΔT at nominal heat input (CH and DHW)
Flue gas flow at minimum heat input
g/s
0.89
1.33
CO2 at nominal heat output
Methane
%
9.0
9.0
9.0
CO2 at nominal heat output
Propane
%
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
Residual available head at minimum heat input
Pa
1.4
1.6
2.0 20
Supply pressure
Methane
mbar
20
20
Supply pressure
Propane
mbar
37
37
37
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
131
131
133
IPX4D
IPX4D
IPX4D
Gas fitting
G½
G½
G½
CH fittings
G¾
G¾
G¾
DHW fittings
G½
G½
G½
Power supply voltage/frequency
Electric protection rating
LxHxD
mm
400x700x250
Net weight
kg
28.50
30.00
31.50
Gross weight
kg
30.50
32.00
33.50
45
CONDENSING BOILERS CONDENSING BOILERS
WALL-HUNG CONDENSING COMBI BOILERS
ANTEA KR
➲
Ultra-compact
➲
Modulation range 1:9
➲
Ready for connection with external probe (optional)
➲
Additional relay managing 2 heating zones
➲
Expansion vessel 9 lt.
➲
Boiler hydraulic replacement kit
➲
LCD user interface Available heat outputs:
12 kW
24 kW
Pre-set to run on Methane or Propane
WARM COMFORT
46
28 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermopolymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air-to-gas ratio • Variable-speed combustion fan • 3-speed pump with integrated air purging device • Flame modulation in heating • Wide modulation range 1:9 • Possible connection of additional complex zones and heat pumps • Low power consumption in stand-by in accordance with EuP Directive • Multifunctional relay for connection or to boiler shutdown alarms or to simple heating zones • Electronic ignition, flame detection via ionization • NTC temperature probes for central heating • LCD interface with diagnostics Wall-hung condensing boiler with premix burner, heating only, sealed chamber. Available with heat output of 12.6, 24.9 and 27.9 kW (50°C - 30°C). Pre-set to run on Methane or Propane.
Model
ANTEA KR 12
ANTEA KR 24
ANTEA KR 28
• Internal by-pass fitted as standard • Pre-set for connection to: external probe, remote control, PCB for low-temperature zone, PCB for solar system • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297/EN 483): 5
Type of gas
Code
METHANE
CAOxx2RR12
PROPANE
CAOxx6RR12
METHANE
CAOxx2RR24
PROPANE
CAOxx6RR24
METHANE
CAOxx2RR28
PROPANE
CAOxx6RR28
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
29.50
24.9
105.1 %
32.00
27.9
105.5 %
31.00
THE PRICE INCLUDES: Paper template, dowels, air-intake blanking cap for air intake opening.
47
ANTEA KR Article
Dimensions and connection centre distances
Description
Code
Flow - return cold water 90° taps kit
0KITIDBA11
245
700
52
126
152,5
G
0KITIDBA13
“Plus” hydraulic kit (copper pipes, square cocks and bicones)
0KITIDBA14
F
400
SV
250
G
F
81
62
67
82
126
63
G Gas inlet (½”) M CH flow (¾”) C DHW outlet (½”) SV Safety valve drain cock
F Cold water inlet (½”) R CH return (¾”) S Condensate drain
ACCESSORIES
WARM COMFORT
81 82
63
Split pipe kit Ø 80+80
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Hot water storage temperature probe
0KITSOND00
Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
top view
bottom view
Article
67
91
52
31 114
60
62
152,5
R
66
60
245
M S
66
0KITRUBI04
91
31
R and water tap kit Gas
114
M S
Base hydraulic kit (copper pipes and straight cocks)
Description
Code
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
Pipes and taps cover
0COPETUB00
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Remote control
0CREMOTO04
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
Fixing template (metal)
0DIMMECO10
Replacement kit Tahiti/Antea
0KITSOST07
Wall spacer kit
0DISTANZ00
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
90° elbow and flange kit Ø 60/100
0KCURFLA00
Electric zone kit with external probe
0KITZONE05
Ø 100/60 mm coaxial kit
0KITATCO00
External probe
0SONDAES01
Sludge remover
0KITDEFA00
Temperature probe for solar heating plants
PSPTMILL00
48
TECHNICAL SPECIFICATIONS
KR 12
KR 24
KR 28 26.4
Nominal heat input
kW
12.0
23.7
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
Minimum heat output (50-30°C)
kW
2.1
3.2
3.5
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
Useful efficiency at 30%
%
106.0
106.5
107.0
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
Casing heat loss with burner off
%
0.55
0.28
0.25
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
%
1.92
2.09
2.00
★★★★
★★★★
★★★★
5
5
5
bar
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
20-78
20-78
20-78
Chimney heat loss with burner on at minimum heat input Energy efficiency marking (92/42/EC) NOx class (EN 297/EN 483) CH maximum working pressure
Expansion vessel capacity
l
9
9
9
3
Consumption at nominal heat output (CH)
Methane
m /h
1.27
2.51
2.79
Consumption at nominal heat output (CH)
Propane
kg/h
0.93
1.84
2.05
DHW maximum working temperature
°C
65
65
65
DHW temperature range
°C
36-65
36-65
36-65
Air-flue ΔT at nominal heat input (CH and DHW)
°C
57.9
61.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
Flue gas flow at nominal heat input (CH and DHW)
g/s
8.25
12.43
13.93
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
%
9.0
9.0
9.0
CO2 at nominal heat output
Methane
CO2 at nominal heat output
Propane
%
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
20
20
20
Supply pressure
Methane
mbar
Supply pressure
Propane
mbar
37
37
37
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
131
131
133
Power supply voltage/frequency
Electric protection rating
IPX4D
IPX4D
IPX4D
Gas fitting
Ø
G½
G½
G½
CH fittings
Ø
G¾
G¾
G¾
Cold water inlet fitting
Ø
G½
G½
G½
LxHxD
mm
400x700x250
Net weight
kg
27.50
30.00
29.00
Gross weight
kg
29.50
32.00
31.00
49
CONDENSING BOILERS CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS
ANTEA KRB
➲
Ultra-compact
➲
Modulation range 1:9
➲
LCD user interface
➲
Ready for connection with external probe (optional)
➲
Additional relay managing 2 heating zones
➲
Expansion vessel 9 lt.
➲
Boiler hydraulic replacement kit Available heat outputs:
12 kW
24 kW
Pre-set to run on Methane or Propane
WARM COMFORT
50
28 kW
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILERS, PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
• Thermopolymer-covered stainless steel heat exchanger • Fully pre-mixed burner • Modulating gas valve with constant air-to-gas ratio • Variable-speed combustion fan • 3-speed pump with integrated air purging device • Flame modulation in heating and DHW modes • Wide modulation range 1:9 • Possible connection of additional complex zones and heat pumps • Low power consumption in stand-by in accordance with EuP Directive • Multifunctional relay for alarms or simple zones • Electronic ignition, flame detection via ionization • NTC temperature probes for central heating • LCD interface with diagnostics • By-pass fitted as standard • Motorised diverter valve
Wall-hung condensing boiler with premix burner, heating only, sealed chamber. Available with heat output of 12.6, 24.9 and 27.9 kW (50°C - 30°C). Pre-set to run on Methane or Propane.
Model
ANTEA KRB 12
ANTEA KRB 24
ANTEA KRB 28
• Ready for connection to: external probe, remote control, PCB for low-temperature zone, PCB for solar system • Energy efficiency marking (92/42/EC): ★★★★ • NOx emission class (EN 297): 5
Type of gas
Code
METHANE
CAOxx2RU12
PROPANE
CAOxx6RU12
METHANE
CAOxx2RU24
PROPANE
CAOxx6RU24
METHANE
CAOxx2RU28
PROPANE
CAOxx6RU28
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
29.50
24.9
105.1 %
31.00
27.9
105.5 %
32.50
THE PRICE INCLUDES: Paper template, dowels, air-intake blanking cap for air intake opening.
51
ANTEA KRB Article
Dimensions and connection centre distances
Description
Code
Flow - return cold water 90° taps kit
0KITIDBA11
245
52
126
152,5
0KITISTI09
700
Horizontal hydraulic kit with cocks
MB
G
RB
G
0KITSDOP00
Connection kit for complex solar systems
0KITSOLC08
Hot water storage temperature probe
0KITSOND00
Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
91
81 60
62
67
82
63
245
RB
152,5
M 81
66
60
62
67
82
126
91
52
31
R
114
S
Split pipe kit Ø 80+80
31
66
MB
0KITRUBI04
250
400
SV
Gas and water tap kit
R
114
M S
63
bottom view
top view
G Gas inlet (½”) M CH flow (¾”) MB Flow to the water tank SV Safety valve drain cock
RB Return from the water tank R CH return (¾”) S Condensate drain
ACCESSORIES Article
WARM COMFORT
Description
Code
Ø 100/60 mm, 0.75 metre coaxial kit
0CONDASP00
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Pipes and taps cover
0COPETUB00
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
Remote control
0CREMOTO04
Replacement kit Tahiti/Antea
0KITSOST07
Fixing template (metal)
0DIMMECO10
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Wall spacer kit
0DISTANZ00
Electric zone kit with external probe
0KITZONE05
90° elbow and flange kit Ø 60/100
0KCURFLA00
External probe
0SONDAES01
Ø 100/60 mm coaxial kit
0KITATCO00
Temperature probe for solar heating plants
PSPTMILL00
Sludge remover
0KITDEFA00
52
TECHNICAL SPECIFICATIONS
KRB 12
KRB 24
KRB 28
Nominal heat input
kW
12.0
23.7
26.4
Nominal heat output (80-60°C)
kW
11.6
22.9
25.4
Nominal heat output (50-30°C)
kW
12.6
24.9
27.9
Minimum heat output (80-60°C)
kW
1.8
2.7
3.0
Minimum heat output (50-30°C)
kW
2.1
3.2
3.5
Useful efficiency at nominal heat input (80-60°C)
%
97.1
96.7
96.4
Useful efficiency at minimum heat input (80-60°C)
%
90.3
91.4
92.3
Useful efficiency at nominal heat input (50-30°C)
%
105.1
105.1
105.5
Useful efficiency at minimum heat input (50-30°C)
%
105.0
104.9
104.5
Useful efficiency at 30%
%
106.0
106.5
107.0
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
Casing heat loss with burner off
%
0.55
0.28
0.25
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
%
1.92
2.09
2.00
★★★★
★★★★
★★★★
5
5
5
bar
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
20-78
20-78
20-78
Chimney heat loss with burner on at minimum heat input Energy efficiency marking (92/42/EC) NOx class (EN 297/EN 483) CH maximum working pressure
Expansion vessel capacity
l
9
9
9
3
Consumption at nominal heat output (CH)
Methane
m /h
1.27
2.51
2.79
Consumption at nominal heat output (CH)
Propane
kg/h
0.93
1.84
2.05
DHW maximum working temperature
°C
65
65
65
DHW temperature range
°C
36-65
36-65
36-65
Air-flue ΔT at nominal heat input (CH and DHW)
°C
57.9
61.0
60.0
Air-flue ΔT at minimum heat input
°C
34.5
33.0
45.0
Flue gas flow at nominal heat input (CH and DHW)
g/s
8.25
12.43
13.93
Flue gas flow at minimum heat input
g/s
0.89
1.33
1.47
%
9.0
9.0
9.0
CO2 at nominal heat output
Methane
CO2 at nominal heat output
Propane
%
10.0
10.0
10.0
Residual available head at nominal heat input
Pa
114
130
170
Residual available head at minimum heat input
Pa
1.4
1.6
2.0
20
20
20
Supply pressure
Methane
mbar
Supply pressure
Propane
mbar
37
37
37
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
131
131
133
Power supply voltage/frequency
Electric protection rating
IPX4D
IPX4D
IPX4D
Gas fitting
Ø
G½
G½
G½
CH fittings
Ø
G¾
G¾
G¾
Cold water inlet fitting
Ø
G½
G½
G½
LxHxD
mm
400x700x250
Net weight
kg
27.50
29.00
30.50
Gross weight
kg
29.50
31.00
32.50
53
CONDENSING BOILERS CONDENSING BOILERS
HEAT ONLY WALL-HUNG CONDENSING BOILERS with 3-way valve
GIAVA KRB
➲
130-lt. single coil hot water storage
➲ Touch screen user interface ➲ Modulation range 1:9 Control of heating zones via ➲ temperature probes (V/Z version)
Versions availbale with hydraulic ➲ kit managing up to 3 high and low temperature zones ➲ Front door Available with the following outputs:
12 kW
24 kW
28 kW
32 kW
The following versions are also available: KRBS-V pre-set for management of two heating areas: one high temperature and the other low temperature. KRBS-Z pre-set for management of three heating areas: one high temperature and two low temperature. WARM COMFORT
54
MURALI A CONDENSING BOILERS CONDENSAZIONE
CONDENSING THERMAL UNIT WITH PREMIX BURNER AND INTEGRATED 130-LT DHW STORAGE
• • • • • • • • • • • • • • • Model GIAVA KRB 12 GIAVA KRB 24 GIAVA KRB 28 GIAVA KRB 32 GIAVA KRB V 12 GIAVA KRB V 24 GIAVA KRB V 28 GIAVA KRB V 32 GIAVA KRB Z 12 GIAVA KRB Z 24 GIAVA KRB Z 28 GIAVA KRB Z 32
Thermopolymer-covered stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air-to-gas ratio Ready for connection to a GSM modem for remote switching on and off and malfunction alarm (optional equipment) Variable-speed combustion fan 130-lt. single coil hot water storage 3 Speed pump with integrated air purging device CH three-way deviating valve for DHW production 10-lt. CH expansion vessel 5-lt. DHW expansion vessel CH and hot water storage freeze protection function Hot water storage anti-Legionnaires’ disease function Hydraulic connections on the side Energy efficiency marking (92/42/EC) ★★★★ NOx emission class (EN 297): 5
Type of gas
Code
METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE METHANE PROPANE
CGBxx2RU12 CGBxx6RU12 CGBxx2RU24 CGBxx6RU24 CGBxx2RU28 CGBxx6RU28 CGBxx2RU32 CGBxx6RU32 CGBxx2TA12 CGBxx6TA12 CGBxx2TA24 CGBxx6TA24 CGBxx2TA28 CGBxx6TA28 CGBxx2TA32 CGBxx6TA32 CGBxx2TB12 CGBxx6TB12 CGBxx2TB24 CGBxx6TB24 CGBxx2TB28 CGBxx6TB28 CGBxx2TB32 CGBxx6TB32
THE PRICE INCLUDES: Air-intake blanking tap kit. 55
Heat output kW (50°C - 30°C)
Efficiency at nominal heat output (50°C - 30°C)
Gross weight (kg)
12.6
105.1 %
189.00
24.9
105.1 %
190.00
27.9
105.5 %
192.00
32.3
106.2 %
195.00
12.6
105.1 %
201.00
24.9
105.1 %
203.00
27.9
105.5 %
204.00
32.3
106.2 %
205.00
12.6
105.1 %
204.00
24.9
105.1 %
206.00
27.9
105.5 %
207.00
32.3
106.2 %
208.00
GIAVA KRB Dimensions and connection centre distances
MAT 1
ACCESSORIES 173
Article
MBT 2
Description 1783
Code
RBT 2
0CONDASP00
1458
96
1523
RBT 3 MBT 3
1328
ACS
1393 AFS
Remote Control 1263
1857
RC
92 190 0CREMOTO04
1133 1071
42
90° elbow and flange kit Ø 60/100
0KCURFLA00
Ø 100/60 mm coaxial kit
0KITATCO00
0
645
MAT 1
GSM kit complete with antenna, feeder, interface PCB, modem
0KITMGSM00
Room temperature probe
0KITSAMB00
Split pipe kit Ø 80+80
0KITSDOP00
Electric kit for management of different temperature zones (with external probe)
0KITZONE05
DHW recirculation kit
0KRICIRC00
External probe (fitted as standard in V and Z models)
0SONDAES01
173 MBT 2
1783
412
GS 1653
RAT 1
43
1588
RBT 2
96
1523
RBT 3
1458 MBT 3 1328
ACS
1393 AFS
92
1263 RC
1857
MAT 1
190
1133 173
1071 MBT 2
1783
412
GS 1653
RAT 1 RBT 2
43
1588
RBT 3
96
1523 1458
MBT 3 1328
ACS
1393 AFS
1857
1263
42
RC
92
(Z model)
42
190
0
1133
top view
1071
AFS Domestic cold water (¾”) MBT 2 Low-temperature zone 2 flow (¾”) MAT 1 High temperature zone 1 flow (¾”) RBT 2 Low temperature zone 2 return (¾”) 0 RBT 3 Low temperature zone 3 return (¾”) MBT 3 Low temperature zone 3 flow (¾”) RAT 1 Low temperature zone 1 return (¾”) GS Gas (½”) RC Recirculation (¾”) ACS DHW (¾”)
WARM COMFORT
56
43
1653
Ø 100/60 mm, 0.75 metre 1588 coaxial kit
412
GS RAT 1
KRB 12
TECHNICAL SPECIFICATIONS Nominal heat input Nominal heat output (80-60 °C) Nominal heat output (50-30 °C) Minimum heat output (80-60 °C) Minimum heat output (50-30 °C) Useful efficiency at nominal heat input(80-60 °C) Useful efficiency at minimum heat input (80-60 °C) Useful efficiency at nominal heat input(50-30 °C) Useful efficiency at minimum heat input (50-30 °C) Useful efficiency at 30% Casing heat loss with burner on at nominal heat input Casing heat loss with burner on at minimum heat input Casing heat loss with burner off Chimney heat loss with burner on at nominal heat input Chimney heat loss with burner on at minimum heat input Energy efficiency marking (92/42/EC) Nox emission class (EN 297/EN 483) CH maximum working pressure CH maximum working temperature CH temperature range CH Expansion vessel capacity Consumption at nominal heat output (CH) Consumption at nominal heat output (CH) Energy efficiency marking for DHW production according to EN 13203-1 DHW nominal heat input (ΔT 30°C) DHW minimum heat input(ΔT 30°C) DHW nominal heat input DHW minimum heat output DHW maximum pressure DHW minimum pressure DHW nominal flow at ∆T 30°C DHW maximum working temperature (with heat integration from the boiler) DHW temperature range (with heat integration from the boiler) DHW expansion vessel capacity Consumption at nominal heat output (DHW) Consumption at nominal heat output (DHW) Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 at nominal heat input CO2 at nominal heat input Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure Supply pressure Power supply voltage/frequency Fuse on the power supply Power absorption (standard models) Power absorption (V model) Power absorption (Z model) Electric protection rating Gas fitting CH fittings DHW fittings LxHxD Net weight Gross weight 57
kW kW kW kW kW % % % % % % % % % % bar °C °C l Methane Propane
Methane Propane
Methane Propane
Methane Propane
m3/h kg/h kW kW kW kW bar bar l/min °C °C l m3/h kg/h °C °C g/s g/s % % Pa Pa mbar mbar V/Hz A W W W mm kg kg
12.0 11.6 12.6 1.8 2.1 97.1 90.3 105.1 105.0 106.0 0.26 7.78 0.55 2.64 1.92 ★★★★ 5 3.0 83 20-78 10 1.27 0.93 ★★★ 17.5 1.8 18.0 2.0 6.0 0.5 19.5 65 35-65 5 1.90 1.40 57.9 34.5 8.25 0.89 9.0 10.0 114 1.4 20 37 230/50 3.15 107 281 378 IPX5D G½ G¾ G½ 158.00 189.00
KRB 24
KRB 28
23.7 26.4 22.9 25.4 24.9 27.9 2.7 3.0 3.2 3.6 96.7 96.4 91.4 92.3 105.1 105.5 104.9 104.5 106.5 107.0 0.97 1.40 6.49 5.70 0.28 0.25 2.62 2.40 2.09 2.00 ★★★★ ★★★★ 5 5 3.0 3.0 83 83 20-78 20-78 10 10 2.51 2.79 1.84 2.05 ★★★ ★★★ 26.8 29.3 2.7 3.0 27.3 30.4 3.0 3.3 6.0 6.0 0.5 0.5 22.0 22.5 65 65 35-65 35-65 5 5 2.89 3.22 2.12 2.36 61.0 60.0 33.0 45.0 12.43 13.93 1.33 1.47 9.0 9.0 10.0 10.0 130 170 1.6 2.0 20 20 37 37 230/50 230/50 3.15 3.15 116 118 289 292 390 392 IPX5D IPX5D G½ G½ G¾ G¾ G½ G½ 600x1857x642 160.00 161.00 190.00 192.00
KRB 32 30.4 29.4 32.3 3.9 4.4 96.8 92.9 106.2 104.8 108.3 0.99 5.06 0.22 2.61 2.04 ★★★★ 5 3.0 83 20-78 10 3.22 2.36 ★★★ 33.4 3.9 34.5 4.2 6.0 0.5 23.4 65 35-65 5 3.65 2.68 60.0 40.5 15.81 1.87 9.0 10.0 183 3.5 20 37 230/50 3.15 126 300 400 IPX5D G½ G¾ G½ 162.00 193.00
CONDENSING BOILERS
FLOOR STANDING condensing boilers with an integrated hot water storage
madeira solar compact kbs
➲
170-lt. single coil solar hot water storage
➲
Touch screen user interface
➲
Modulation range 1:9
Control of heating zones via ➲ temperature probes (V/Z version)
Versions availbale with hydraulic kit managing up to ➲ 3 high and low temperature zones ➲
12-lt. solar expansion vessel
➲
Front door Available heat outputs:
24 kW
kW
The following versions are also available: KRBS-V pre-set for management of two heating areas: one high temperature and the other low temperature. KRBS-Z pre-set for management of three heating areas: one high temperature and two low temperature.
Temperature probe (supplied as standard) for solar plants
WARM COMFORT
32
58
MURALI A CONDENSING BOILERS CONDENSAZIONE
CONDENSING THERMAL UNIT WITH PREMIX BURNER AND INTEGRATED 170-LT DHW SINGLE COIL STORAGE, COMPLETE WITH HYDRAULIC AND ELECTRONIC SYSTEMS ALLOWING MANAGEMENT OF A SOLAR HEATING PLANT
• • • • • •
Fully pre-mixed burner Variable-speed combustion fan 170-lt. single coil solar hot water storage 3-speed CH circulation pump with air-purging device CH three-way deviating valve for DHW inegration Ready for connection to a GSM modem for remote switching on and off and malfunction alarm (optional equipment) • 10-lt. CH expansion vessel • 12-lt. DHW expansion vessel • 12-lt. solar expansion vessel • NTC temperature probes on CH and hot water storage • Easy access to boiler internal parts through front door • Hydraulic connections on the side • DHW thermostatic mixing valve • CH frost protection function • Energy efficiency marking (92/42/EC) ★★★★ • NOx emission class (EN 297): 5 • Electronic board for solar plant management • Integrated hydraulic system for solar system management including: - 3-speed solar circulation pump - flow and return intercepting valves with thermometers - flow adjuster with flow meter having adjustment field from 0.5 to 15l/1’ - 6 bar solar plant safety valve
Model MADEIRA SOLAR COMPACT KBS 24 MADEIRA SOLAR COMPACT KBS 32 MADEIRA SOLAR COMPACT KBS V 24 MADEIRA SOLAR COMPACT KBS V 32 MADEIRA SOLAR COMPACT KBS Z 24 MADEIRA SOLAR COMPACT KBS Z 32
Type of gas
Code
METHANE
CMCxx24M24
PROPANE
CMCxx64M24
METHANE
CMCxx24M32
PROPANE
CMCxx64M32
METHANE
CMCxx24N24
PROPANE
CMCxx64N24
METHANE
CMCxx24N32
PROPANE
CMCxx64N32
METHANE
CMCxx24P24
PROPANE
CMCxx64P24
METHANE
CMCxx24P32
PROPANE
CMCxx64P32
Heat output kW (50°C - 30°C)
Efficiency at nominal heat output (50°C - 30°C)
Gross weight (kg)
24.9
105.1 %
206.00
32.3
106.2 %
209.00
24.9
105.1 %
218.00
32.3
106.2 %
221.00
24.9
105.1 %
221.00
32.3
106.2 %
224.00
THE PRICE INCLUDES: Air-intake blanking tap kit, temperature probe for solar plants. 59
MADEIRA SOLAR COMPACT KBS Dimensions and connection centre distances
ACCESSORIES MAT1
Article
Description
Code173 1783
MBT1
1653
RAT1
Ø 100/60 mm, 0.75 metre1588 coaxial kit
RBT2
1458
RBT3
1393
MBT3
Remote Control
ACS
1328 1263
0CREMOTO04
AF
1133
RSS
1071
MSS
GSM kit complete with antenna, feeder, interface PCB, modem
0KITMGSM00
Room temperature probe
0KITSAMB00
0
0KITSDOP00
92
1857
645
0CONDASP00
96
1523
412
GS
1006
42
600
Split pipe kit Ø 80+80
MAT1 173
190
1783
MBT1
1653
GS RAT1
MBT3 MAT1
ACS
1857
AF MBT1
RSS
1458
MAT R MBT1 GS RAT RBT1 RBT2 MBT2 ACS AF RSS MSS
1393 Descrizione
1 Mandata / Mandata 1328 A.T* 2 Ritorno
1263
3 Mandata B.T. 4 Gas
Note
1133
173
G3/4 M
Versione senza zone
G 3/4 M
Versione VeZ 190
G3/4 M
92
1783 1071
G 1/2 M
1653 1006
G 3/4 M
Versioni V e Z
G 3/4 M
7 Ritorno B.T.
Versione Z
G 3/4 M
RBT3
8 Mandata B.T.
Versione Z
MBT3
9 ACS
RBT2
1588
6 Ritorno B.T. 1523 1458
ACS
G 3/4 M
96
1393
43
RAT1
5 Ritorno A.T.
412
MSS
G 3/4 M
1328
10 Acqua fredda 1263
G 1/2 M
11 Ritorno al 1133 pannello solare*
AF
Pannello solare non incluso
1006
MSS
42
600
0
Pannello solare non incluso
top view
(Z model) MAT1 High temperature zone 1 flow (¾”) MBT2 Low-temperature zone 2 flow (¾”) GS Gas (½”) Note Dimensione attacchi RAT1 Low temperature zone 1 return (¾”) *Versione V e Z G3/4 M 0 42 Versione senza zone G 3/4 M RBT2 Low temperature zone 2 return (¾”) Versione V e Z G3/4 M RBT3 Low temperature zone 3 return (¾”) G 1/2 M MBT3 Low temperature zone 3 flow (¾”) Versioni V e Z G 3/4 M Versioni V e Z G 3/4 M ACS DHW (¾”) Versione Z G 3/4 M AF Cold water (¾”) Versione Z G 3/4 M G 3/4 M RSS Return from solar coil(¾”) G 1/2 M MSS Flow to solar coil (¾”) Note Dimensione attacchi
Pannello solare non incluso G 3/4 M Versione V e Z G3/4 M * Pannello solare non incluso G 3/4 M ersione senza zone G 3/4 M
ersione V e Z
G 3/4 M
92 1071pannello solare* 12 Mandata dal
RSS
G3/4 M G 1/2 M
WARM COMFORT
ersioni V e Z
G 3/4 M
ersioni V e Z
G 3/4 M
ersione Z
G 3/4 M
External probe (fitted as standard in V and Z models)
0SONDAES01
Dimensione attacchi
*Versione V e Z
Versioni V e Z
GS
1857
Rif
96
RBT3
43
1523
RBT2
0KITZONE05
412
1588
Electric kit for management of different temperature zones (with external probe)
60
G 3/4 M
190
TECHNICAL SPECIFICATIONS
KBS 24
Nominal heat input
kW
Nominal heat output (80-60 °C) Nominal heat output (50-30 °C) Minimum heat output (80-60 °C) Minimum heat output (50-30 °C) Useful efficiency at nominal heat input(80-60 °C) Useful efficiency at minimum heat input (80-60 °C) Useful efficiency at nominal heat input(50-30 °C) Useful efficiency at minimum heat input (50-30 °C) Useful efficiency at 30% Casing heat loss with burner on at nominal heat input Casing heat loss with burner on at minimum heat input Casing heat loss with burner off Chimney heat loss with burner on at nominal heat input Chimney heat loss with burner on at minimum heat input Energy efficiency marking (92/42/EC) NOx emission class (EN 297/EN 483) CH maximum working pressure CH maximum working temperature CH temperature range CH expansion vessel capacity Consumption at nominal heat output (CH)(80-60 °C) Consumption at nominal heat output (CH) Energy efficiency marking for DHW production according to EN 13203-1 DHW nominal heat input (ΔT 30°C) DHW minimum heat output (ΔT 30°C) DHW minimum heat input DHW minimum heat input DHW maximum pressure DHW minimum pressure DHW nominal flow at ΔT 30°C (EN 625) DHW maximum working temperature DHW temperature range CH Expansion vessel capacity Consumption at nominal heat output (DHW) Consumption at nominal heat output (DHW) Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 at nominal heat input CO2 at nominal heat input Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure Supply pressure Power supply voltage/frequency Fuse on the power supply Power absorption (standard models) Power absorption (V model) Power absorption (Z model) Electric protection rating Gas fitting CH fittings DHW fittings L xHxD Gross weight
kW kW kW kW % % % % % % % % % % bar °C °C l Methane Propane
Methane Propane
Methane Propane
Methane Propane
61
m3/h kg/h kW kW kW kW bar bar l/min °C °C l m3/h kg/h °C °C g/s g/s % % Pa Pa mbar mbar V/Hz A W W W mm kg
KBS 32
23.7 30.4 22.9 29.4 24.9 32.3 2.7 3.9 3.2 4.4 96.7 96.8 91.4 92.9 105.1 106.2 104.9 104.8 106.5 108.3 0.97 0.99 6.49 5.06 0.28 0.22 2.62 2.61 2.09 2.04 ★★★★ ★★★★ 5 5 3.0 3.0 83 83 20-78 20-78 10 10 2.51 3.22 1.84 2.36 ★★★ ★★★ 27.4 33.4 3.0 3.9 27.3 34.5 3.0 4.2 6.0 6.0 0.5 0.5 13.4 16.2 62 62 35-57 35-57 12 12 2.89 3.65 2.12 2.68 61.0 60.0 33.0 40.5 12.43 15.81 1.33 1.87 9.0 9.0 10.0 10.0 130 183 1.6 3.5 20 20 37 37 230/50 230/50 3.15 3.15 122 139 296 312 396 412 IPX5D IPX5D G½ G½ G¾ G¾ G½ G½ 600x1857x642 206.00 209.00
CONDENSING BOILERS
SOLAR READY FLOOR STANDING CONDENSING BOILERS
madeira solar KRBS
➲
300-lt. double coil hot water storage
➲
Touch screen user interface
➲
Modulation range 1:9
➲
Control of heating zones via temperature probes (V/Z version)
➲
Versions availbale with hydraulic kit managing up to 3 high and low temperature zones
➲
18-lt. solar expansion vessel
➲
Front door
Available with the following outputs:
12 kW
kW
28 kW
32 kW
The following versions are also available: KRBS-M pre-set with 3-way solar deviation valve for thermal discharge KRBS-V pre-set for management of two heating areas: one high temperature and the other low temperature. KRBS-Z pre-set for management of three heating areas: one high temperature and two low temperature. KRBS-MV pre-set with 3-way solar deviation valve for thermal discharge - pre-set for management of two heating areas: one high temperature and the other low temperature. KRBS-MZ pre-set with 3-way solar deviation valve for thermal discharge - pre-set for management of three heating areas: one high temperature and two low temperature.
Temperature probe (supplied as standard) for solar plants
WARM COMFORT
24
62
CONDENSING BOILERS
SCONDENSING THERMAL UNIT WITH PREMIX BURNER AND INTEGRATED 300-LT DHW DOUBLE COIL STORAGE, COMPLETE WITH HYDRAULIC AND ELECTRONIC SYSTEMS ALLOWING MANAGEMENT OF A SOLAR HEATING PLANT • • • • • •
Fully pre-mixed burner Variable-speed combustion fan 300-lt. double coil hot water storage Modulating pump with air-purging device CH three-way deviating valve for DHW inegration Ready for connection to a GSM modem for remote switching on and off and malfunction alarm (optional equipment) • 10-lt. CH expansion vessel • 12-lt. DHW expansion vessel • 18-lt. solar expansion vessel
Model
Type of gas
Code
MADEIRA SOLAR KRBS 12
METHANE
CMBxx24A12
PROPANE
CMBxx64A12
MADEIRA SOLAR KRBS 24
METHANE
CMBxx24A24
PROPANE
CMBxx64A24
MADEIRA SOLAR KRBS 28
METHANE
CMBxx24A28
PROPANE
CMBxx64A28
MADEIRA SOLAR KRBS 32
METHANE
CMBxx24A32
PROPANE
CMBxx64A32
MADEIRA SOLAR KRBS M 12
METHANE
CMBxx24B12
PROPANE
CMBxx64B12
MADEIRA SOLAR KRBS M 24
METHANE
CMBxx24B24
PROPANE
CMBxx64B24
MADEIRA SOLAR KRBS M 28
METHANE
CMBxx24B28
PROPANE
CMBxx64B28
MADEIRA SOLAR KRBS M 32
METHANE
CMBxx24B32
PROPANE
CMBxx64B32
MADEIRA SOLAR KRBS V 12
METHANE
CMBxx24C12
PROPANE
CMBxx64C12
MADEIRA SOLAR KRBS V 24
METHANE
CMBxx24C24
PROPANE
CMBxx64C24
MADEIRA SOLAR KRBS V 28
METHANE
CMBxx24C28
PROPANE
CMBxx64C28
MADEIRA SOLAR KRBS V 32
METHANE
CMBxx24C32
PROPANE
CMBxx64C32
• • • • •
5-lt. additional solar expansion vessel Hydraulic connections on the side DHW thermostatic mixing valve Electronic board for solar plant management Integrated hydraulic system for solar system management including: - 3-speed solar circulation pump - flow and return intercepting valves with thermometers - flow adjuster with flow meter having adjustment field from 0.5 to 15l/1’ - 6 bar solar plant safety valve
Heat output kW (50°C - 30°C)
Efficiency at nominal heat output (50°C - 30°C)
Gross weight (kg.)
Model
12.6
105.1 %
270.00
24.9
105.1 %
27.9
Type of gas
Code
MADEIRA SOLAR KRBS MV 12
METHANE
CMBxx24E12
PROPANE
CMBxx64E12
272.00
MADEIRA SOLAR KRBS MV 24
METHANE
CMBxx24E24
PROPANE
CMBxx64E24
105.5 %
273.00
MADEIRA SOLAR KRBS MV 28
METHANE
CMBxx24E28
PROPANE
CMBxx64E28
32.3
106.2 %
274.00
MADEIRA SOLAR KRBS MV 32
METHANE
CMBxx24E32
PROPANE
CMBxx64E32
12.6
105.1 %
271.00
MADEIRA SOLAR KRBS Z 12
METHANE
CMBxx24J12
PROPANE
CMBxx64J12
24.9
105.1 %
273.00
MADEIRA SOLAR KRBS Z 24
METHANE
CMBxx24J24
PROPANE
CMBxx64J24
27.9
105.5 %
274.00
MADEIRA SOLAR KRBS Z 28
METHANE
CMBxx24J28
PROPANE
CMBxx64J28
32.3
106.2 %
275.00
MADEIRA SOLAR KRBS Z 32
METHANE
CMBxx24J32
PROPANE
CMBxx64J32
12.6
105.1 %
283.00
MADEIRA SOLAR KRBS MZ 12
METHANE
CMBxx24K12
PROPANE
CMBxx64K12
24.9
105.1 %
284.00
MADEIRA SOLAR KRBS MZ 24
METHANE
CMBxx24K24
PROPANE
CMBxx64K24
27.9
105.5 %
286.00
MADEIRA SOLAR KRBS MZ 28
METHANE
CMBxx24K28
PROPANE
CMBxx64K28
32.3
106.2 %
287.00
MADEIRA SOLAR KRBS MZ 32
METHANE
CMBxx24K32
PROPANE
CMBxx64K32
THE PRICE INCLUDES: Air-intake blanking tap kit, temperature probe for solar plants. 63
Heat output kW (50°C - 30°C)
Efficiency at nominal heat output (50°C - 30°C)
Gross weight (kg.)
12.6
105.1 %
283.00
24.9
105.1 %
285.00
27.9
105.5 %
283.00
32.3
106.2 %
287.00
12.6
105.1 %
286.00
24.9
105.1 %
287.00
27.9
105.5 %
289.00
32.3
106.2 %
291.00
12.6
105.1 %
287.00
24.9
105.1 %
288.00
27.9
105.5 %
290.00
32.3
106.2 %
291.00
MADEIRA SOLAR KRBS Dimensions and connection centre distances
ACCESSORIES MAT1
GS RAT1 RBT 2
1783 1653 1588
Ø 100/60 mm, 0.75 metre 1523 coaxial 1458 kit 1393
RBT3 MBT3 ACS AF
190
Code
0CONDASP00 754
MBT2
173
Description
1328 1263 1133
Remote Control 981
96
Article
0CREMOTO04
RSS RC
851 786
MSS MST RST
721
92
90° elbow and flange kit Ø 60/100
0KCURFLA00
Ø 100/60 mm coaxial kit
0KITATCO00
0 988
600
MAT1 173
190
1783
MBT2 GS
GSM kit complete with antenna, feeder, interface PCB, modem
0KITMGSM00
Room temperature probe
0KITSAMB00
Split pipe kit Ø 80+80
0KITSDOP00
Electric kit for management of different temperature zones (with external probe)
0KITZONE05
DHW recirculation kit
0KRICIRC01
External probe (fitted as standard in V and Z models)
0SONDAES01
1653 1588
RAT1
1523 754
1458
RBT 2
1393
MAT1
RBT3
1328 173
1263
MBT3
190
1783
MBT2
ACS 1588
RAT1
1523
RSS
981
1458
RBT 2
RC RBT3
1393
851
1328
786
1263
MBT3 MSS ACS
754
1653
AF
96
1133
GS
721
92
1133 43
MST
96
AF
RST
981
RSS 851
RC
786 MSS
721
92
MST
top view
RST
0 600
(Z model) 0 MAT1 High temperature zone 1 flow (¾”) MBT2 Low-temperature zone 2 flow (¾”) GS Gas (½”) RAT1 Low temperature zone 1 return (¾”) RBT2 Low temperature zone 2 return (¾”) RBT3 Low temperature zone 3 return (¾”) MBT3 Low temperature zone 3 flow (¾”) ACS DHW (¾”) AF Cold water (¾”) RSS Return from solar coil (¾”) RC Recirculation (¾”) MSS Flow to solar coil (¾”) MST Thermal discharge flow (¾”) RST Thermal discharge return (¾”)
600
WARM COMFORT
64
TECHNICAL SPECIFICATIONS
KRBS 12
KRBS 24
KRBS 28
KRBS 32
Nominal heat input
kW
12.0
23.7
26.4
30.4
Nominal heat output (80-60 °C)
kW
11.6
22.9
25.4
29.4 32.3
Nominal heat output (50-30 °C)
kW
12.6
24.9
27.9
Minimum heat output (80-60 °C)
kW
1.8
2.7
3.0
3.9
Minimum heat output (50-30 °C)
kW
2.1
3.2
3.6
4.4
Useful efficiency at nominal heat input(80-60 °C)
%
97.1
96.7
96.4
96.8
Useful efficiency at minimum heat input (80-60 °C)
%
90.3
91.4
92.3
92.9
Useful efficiency at nominal heat input(50-30 °C)
%
105.1
105.1
105.5
106.2
Useful efficiency at minimum heat input (50-30 °C)
%
105.0
104.9
104.5
104.8 108.3
Useful efficiency at 30%
%
106.0
106.5
107.0
Casing heat loss with burner on at nominal heat input
%
0.26
0.97
1.40
0.99
Casing heat loss with burner on at minimum heat input
%
7.78
6.49
5.70
5.06
Casing heat loss with burner off
%
0.55
0.28
0.25
0.22
Chimney heat loss with burner on at nominal heat input
%
2.64
2.62
2.40
2.61
Chimney heat loss with burner on at minimum heat input
%
1.92
2.09
2.00
2.04
Energy efficiency marking (92/42/EC)
-
★★★★
★★★★
★★★★
★★★★
NOx emission class (EN 297/EN 483) CH maximum working pressure
-
5
5
5
5
bar
3.0
3.0
3.0
3.0
CH max working temperature
°C
83
83
83
83
CH temperature range
°C
20-78
20-78
20-78
20-78
l
10
10
10
10
CH expansion vessel capacity Consumption at nominal heat output (CH)
Methane
Consumption at nominal heat output (CH)
Propane
Energy efficiency marking for DHW production according to EN 13203-1 DHW nominal heat input (ΔT 30°C) DHW minimum heat output (ΔT 30°C) DHW minimum heat input DHW minimum heat input DHW maximum pressure DHW minimum pressure DHW nominal flow at ΔT 30°C (EN 625) DHW maximum working temperature DHW temperature range DHW expansion vessel capacity Consumption at nominal heat output (DHW)
Methane
Consumption at nominal heat output (DHW)
Propane
Air-flue ΔT at nominal heat input (CH and DHW) Air-flue ΔT at minimum heat input Flue gas flow at nominal heat input (DHW) Flue gas flow at minimum heat input CO2 at nominal heat input
Methane
CO2 at nominal heat input
Propane
Residual available head at nominal heat input Residual available head at minimum heat input Supply pressure
Methane
Supply pressure
Propane
Power supply voltage/frequency Fuse on the power supply Power absorption (standard model) Power absorption (V model) Power absorption (Z model) Electric protection rating Gas fitting CH fittings DHW fittings L xHxD 65
m /h kg/h kW kW kW kW bar bar l/min °C °C l m3/h kg/h °C °C g/s g/s % % Pa Pa mbar mbar V/Hz A W W W mm 3
1.27
2.51
2.79
3.22
0.93
1.84
2.05
2.36
★★★
★★★
★★★
★★★
17.5
26.8
29.3
33.4
1.8
2.7
3.0
3.9
18.0
27.3 3.0
30.4
34.5
3.3
4.2
6.0 0.5 23.6
6.0
6.0
0.5
0.5
25.3
26.3
65 35-65
65
65
35-65
35-65
2.0 6.0 0.5 23.6 65 35-65 12
12
12
12
1.90
2.89
3.22
3.65
1.40
2.12
2.36
2.68
57.9
61.0
60.0
60.0
34.5
33.0
45.0
40.5
8.25
12.43
13.93
15.81
0.89
1.33
1.47
1.87
9.0
9.0
9.0
9.0
10.0
10.0
10.0
10.0
114
130
170
183
1.4
1.6
2.0
3.5
20
20
20
20
37
37
37
37
230/50
230/50
230/50
230/50
3.15
3.15
3.15
3.15
105
122
127
139
280
296
301
312
380
396
401
412
IPX5D
IPX5D
IPX5D
IPX5D
G½
G½
G½
G½
G¾
G¾
G¾
G¾
G½
G½
G½
G½
600x1857x985
CONDENSING BOILERS
SOLAR READY FLOOR STANDING CONDENSING BOILERS
BOILERS
high capacity BOILERS
67
CONDENSING BOILERS
CONDENSING
TAHITI CONDENSING KR 55
➲
High efficiency
➲
Low polluting emissions
➲
Wide LCD
➲
Ideal for small-sized central systems
Available with the following outputs:
55 kW
Pre-set to run on Methane or Propane
WARM COMFORT
68
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILER, WITH PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER
• • • • • • • • • •
High-efficiency stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air/gas ratio Variable-speed combustion fan 3-speed circulation pump Air purging device on heat exchanger Built-in air-purging device Water differential (flow-return) and minimum pressure switch Efficiency rating according to 92/42/EC: ★★★★ NOx emission class (EN 297): 5
Ready for connection to: • External hot water storage for domestic hot water (with anti-legionella and freeze protection functions) • Open Therm Remote Control • Zone-specific heating control board for high and low temperature
Model
Type of gas
Code
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
TAHITI CONDENSING LINE TECH KR 55
METHANE
CTOxx2RR55
58.8
107.0 %
65.00
Electric panels for cascade boiler management Electric panels model KR 55
2 boilers
3/4 boilers
5/6 boilers
Standard electric panel
0QUADCAS24
0QUADCAS25
0QUADCAS26
PC electric panel
0QUADCAS30
0QUADCAS31
0QUADCAS32
GSM electric panel
0QUADCAS27
0QUADCAS28
0QUADCAS29
“V3” electric panel
0QUADCAS21
0QUADCAS22
0QUADCAS23
“V4” electric panel
0QUADCAS20
0QUADCAS20
-
THE PRICE INCLUDES: Paper template, air-intake blanking caps kit.
* Pre-set to run on methane (can be transformed to run on propane). 69
TAHITI CONDENSING KR 55 89
135
148
78
Article
Description
Code
30
127
Dimensions and connection centre distances
0KCURFLA00
Coaxial kit Ø 60/100
0KITATCO00
Hydraulic separator kit
0KITISTM06
Split pipe kit Ø 80+80
0KITSDOP00
750
62
90° elbow kit with flange Ø 60/100
135
148
78
50
62
30
127
89
G M
F
R RC
750
135
148
SI
78
43 56
173
Hot water storage temperature probe
0KITSOND00
Electric kit for zone management with external probe
0KITZONE00
Flue check valve, fitting Ø 80, fitting on flue side Ø 100
0PARCALD02
Filter refill Pmax 85 kW
0RICAFIL00
External probe
0SONDAES01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
98
80
62
50
127
89
534
220.5
S 450
G M
F
R RC
450
534
SI
43 56
top view
G
RC
220.5
S SI
43 56
173
98
Article
WARM COMFORT
173
98
80
bottom view
WARNING: This boiler uses flue pipes for condensing boilers or for cascade systems R M F
ACCESSORIES
220.5
S
G Gas inlet (¾”) M CH system flow (1”) F Cold water inlet (½”) R CH system return (1”) S Condensate drain SI Condensate trap RC Filler cock
80
Description
Code
Coaxial kit Ø 60/100 length 0.75 m
0CONDASP00
Boiler cover
0COPERIG01
Remote control
0CREMOTO05
Condensate neutraliser Pmax 85 kW
0FILNECO03
70
TECHNICAL SPECIFICATIONS
KR 55
Nominal heat input
kW
55.0
Nominal heat output (80-60°C)
kW
53.5
Nominal heat output (50-30°C)
kW
58.8
Minimum heat output (80-60°C)
kW
14.1
Minimum heat output (50-30°C)
kW
15.7
Useful efficiency at nominal heat input (80-60°C)
%
97.3
Useful efficiency at minimum heat input (80-60°C)
%
97.0
Useful efficiency at nominal heat input (50-30°C)
%
107.0
Useful efficiency at minimum heat input (50-30°C)
%
108.1
Efficiency at 30%
%
108.9
Casing heat loss with burner on at nominal heat input
%
0.46
Casing heat loss with burner on at minimum heat input
%
0.83
Casing heat loss with burner off
%
0.36
Chimney heat loss with burner on at nominal heat input
%
2.04
Chimney heat loss with burner on at minimum heat input
%
1.89
Energy efficiency marking (92/42/EC)
-
★★★★
NOx emission class (EN 297/EN 483):
-
5
CH maximum working pressure
bar
4.0
Temperatura max esercizio riscaldamento
°C
83
CH temperature range
°C
20 - 78
3
Consumption at nominal heat output (CH)
Methane
m /h
5.82
Consumption at nominal heat output
Propane
kg/h
4.27
Air-flue ΔT at nominal heat input
°C
44.0
Air-flue ΔT at nominal heat input
°C
39.0
Flue gas flow at nominal heat input
g/s
25.10
Flue gas flow at minimum heat input
g/s
6.60
CO2 at nominal heat output
Methane
%
9.0
CO2 at nominal heat output
Propane
%
10.0
Residual available head at nominal heat input
Pa
290
Residual available head at minimum heat input
Pa
23.0
Supply pressure
Methane
mbar
20
Supply pressure
Propane
mbar
37
V/Hz
230/50
Fuse on the power supply
A
2
Power absorption
W
245
Electric protection rating
-
IPX4D
Gas fitting
-
G¾
CH fittings
-
G1
mm
450x750x535
Net weight
kg
52.50
Gross weight
kg
65.00
Power supply voltage/frequency
LxHxD
71
CONDENSING BOILERS
HIGH CAPACITY HEAT ONLY Wall-hung condensing boilers
TAHITI CONDENSING KR 85
➲
High efficiency
➲
Low polluting emissions
➲
Wide LCD
➲
Split pipe starting kit included
➲
Ideal for small-sized central systems
Available with the following outputs:
85 kW
Pre-set to run on Methane or Propane
WARM COMFORT
72
MURALI A CONDENSING BOILERS CONDENSAZIONE
WALL-HUNG CONDENSING BOILER, WITH PREMIX BURNER, HEATING ONLY, SEALED COMBUSTION CHAMBER
• • • • • • • • • •
High-efficiency stainless steel heat exchanger Fully pre-mixed burner Modulating gas valve with constant air/gas ratio Variable-speed combustion fan 3-speed circulation pump Air purging device on heat exchanger Built-in air-purging device Water differential (flow-return) and minimum pressure switch Efficiency rating according to 92/42/EC: ★★★★ NOx emission class (EN 297): 5
Ready for connection to: • External hot water storage (with anti-legionella and freeze protection functions) • Open Therm Remote Control • Zone-specific heating control board for high and low temperature
Model
Type of gas
Code
Heat output kW (50°C - 30°C)
Efficiency at nominal heat ouput (50°C - 30°C)
Gross weight (kg)
TAHITI CONDENSING LINE TECH KR 85
METHANE
CTOxx2RR85
90.4
106.4 %
74.00
Electric panels for cascade boiler management Electric panels model KR 55
2 boilers
3/4 boilers
5/6 boilers
Standard electric panel
0QUADCAS24
0QUADCAS25
0QUADCAS26
PC electric panel
0QUADCAS30
0QUADCAS31
0QUADCAS32
GSM electric panel
0QUADCAS27
0QUADCAS28
0QUADCAS29
“V3” electric panel
0QUADCAS21
0QUADCAS22
0QUADCAS23
“V4” electric panel
0QUADCAS20
0QUADCAS20
-
THE PRICE INCLUDES: Paper template, air-intake blanking tap kit.
* Pre-set to run on methane (can be transformed to run on propane).. 73
TAHITI CONDENSING KR 85 Article 89 135
148
Description
78
42
62
Hydraulic separator kit
135
148
78
Hot water storage temperature probe
0KITSOND00
Electric kit for zone management with external probe
0KITZONE00
F
M
62
42
50
127
89
R
Aspirazione aria Ø80 mm
534
G SI
Flue check valve, fitting Ø 100, fitting on flue side Ø 100 220. 5
Scaric o Ø100 mm
450 750
S
78
Aspirazione aria Air intake Ø80 mm Ø 80 mm
534
S
top view
S
WARNING: F This boiler uses flue pipes R for condensing boilers or for cascade systems Only 100 mm for discarge 80mm for air. RC Coaxal system not available 43 56
173
173
98
80
bottom view
220. 5
G SI
98
G Gas inlet (¾”) M CH system flow (1”) F Cold water inlet (½”) R CH system return (1”) S Condensate drain SI Condensate trap RC Filler cock
80
ACCESSORIES Article
WARM COMFORT
80
Filter refill Pmax 85 kW
0RICAFIL03
External probe
0SONDAES01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
RC 43 56
M
98
R G SI
220. 5
ØScaric 100omm Ø100 mm
173
F
M
62
50
127
148
0PARCALD03
RC 43 56
135
0KITISTM06
Aspirazione aria Ø80 mm
750
Scaric o Ø100 mm
89
Code
127
Dimensions and connection centre distances
Description
Code
Boiler cover
0COPERIG01
Remote control
0CREMOTO05
Condensate neutraliser Pmax 85 kW
0FILNECO03
74
TECHNICAL SPECIFICATIONS
KR 85
Nominal heat input
kW
85.0
Nominal heat output (80-60°C)
kW
82.7
Nominal heat output (50-30°C)
kW
90.4
Minimum heat output (80-60°C)
kW
20.3
Minimum heat output (50-30°C)
kW
22.6
Useful efficiency at nominal heat input (80-60°C)
%
97.3
Useful efficiency at minimum heat input (80-60°C)
%
97.3
Useful efficiency at nominal heat input (50-30°C)
%
106.4
Useful efficiency at minimum heat input (50-30°C)
%
107.7
Efficiency at 30%
%
108.5
Casing heat loss with burner on at nominal heat input
%
0.30
Casing heat loss with burner on at minimum heat input
%
0.93
Casing heat loss with burner off
%
0.48
Chimney heat loss with burner on at nominal heat input
%
2.20
Chimney heat loss with burner on at minimum heat input
%
1.79
Energy efficiency marking (92/42/EC)
-
★★★★
NOx emission class (EN 297/EN 483):
-
5
CH maximum working pressure
bar
4.0
Temperatura max esercizio riscaldamento
°C
83
CH temperature range
°C
20-78
3
Consumption at nominal heat output (CH)
Methane
m /h
8.99
Consumption at nominal heat output
Propane
kg/h
6.60
Air-flue ΔT at nominal heat input
°C
47.0
Air-flue ΔT at nominal heat input
°C
36.0
Flue gas flow at nominal heat input
g/s
38.70
Flue gas flow at minimum heat input
g/s
9.60
CO2 at nominal heat output
Methane
%
9.0
CO2 at nominal heat output
Propane
%
10.0
Residual available head at nominal heat input
Pa
240
Residual available head at minimum heat input
Pa
19.0
Supply pressure
Methane
mbar
20
Supply pressure
Propane
mbar
37
V/Hz
230/50
Fuse on the power supply
A
2
Power absorption
W
245
Electric protection rating
-
IPX4D
Gas fitting
-
G¾
CH fittings
-
G1
mm
450x750x535
Net weight
kg
74.00
Gross weight
kg
86.00
Power supply voltage/frequency
LxHxD
75
CONDENSING BOILERS
HIGH CAPACITY HEAT ONLY Wall-hung condensing boilers
TAHITI CONDENSING
MODULO KR
➲
Wide range of heat outputs available
➲
Can be integrated with external hot water storage
➲
Zone management
➲
GSM or Ethernet remote management
➲
Cabinets with rain-protection
The electrical control board includes circuit breaker switches protecting each boiler and a differential circuit breaker switch protecting the whole modular heat generator. The versions with the cabinet can be requested with hydraulic separator and gas connection, condensate and water drain positioned on the right (right painted cabinet, right stainless steel cabinet) or on the left (left painted cabinet, left stainless steel cabinet). WARM COMFORT
76
MURALI A CONDENSING BOILERS CONDENSAZIONE
MODULAR CONDENSING HEAT GENERATORS FOR CENTRAL THERMAL PLANT
ACCESSORIES • High efficiency stainless steel heat exchangers on individual boilers • Total pre-mixed gas burners • Modulating gas valves with constant air-to-gas ratio • Variable speed combustion fans • Differential (flow-return) and minimun pressure switches • Available in versions: - with stainless steel cabinet for outdoor installation in corrosive environment habitats - with painted steel cabinet for outdoor installations - without cabinet for installation in thermal power plant • Hydraulic separator and collective safety components in the head cabinet (on the right or on the left) • Eyebolts for lifting the cabinet and regulator system for level generator installation • Rack (optional) for installation to the wall for the version without cabinet • Electrical control board for generator management. Pre-set: - standard, without external communication - with data communication to PC for the generator’s Ethernet network management - with data communication via GSM for remote generator management
Article
THE PRICE INCLUDES: Air-intake/flue gas discharge duct, outdoor probe, external cylinder probe, temperature probe on flow. 77
Description
Code
Power supply for modules and modem
0ALIMEMM00
Magnetic based antenna
0ANTENNA00
M/F direct modem RS232 cable
0CAVOSER01
Remote control for thermoregulation control unit (temperature regulation)
0CREMOTO00
Remote control for thermoregulation control unit (all functions)
0CREMOTO01
Condensate neutralizing filter (for boilers with max. output 350 kW)
0FILNECO01
GSM TC35i Modem
0MODEMGS00
Spare cartridge for condensate filter (for boilers with max. output 350 kW)
0RICAFIL01
Low-temperature zone flow probe
0SONDARI01
Wall rack (for two boilers)
0STRUPOR01
Temperature probe for solar heating plants
PSPTMILL00
TAHITI CONDENSING MODULO KR Advanced hard-wired control panel:
Standard Panel
Complete electrical panel equipped with safety devices (differential circuit breakers), pre-assembled in the generator for modules with cabinets. Complete control over the boiler’s parameters via an OpenTherm interface.
Panel with PC interfaceLike the standard panel with an additional serial port interface for connecting to a PC
(software included).
Panel with GSM interface
Like the standard panel with an additional GSM interface for connecting to a PC (software included). Model
Tahiti Condensing Modulo Kr 110
Tahiti Condensing Modulo Kr 140
ACCESSORIES FOR Ø 160 mm FLUE GAS OUTLET
Tahiti Condensing Modulo Kr 170
Tahiti Condensing Modulo Kr 220
Tahiti Condensing Modulo Kr 250
Tahiti Condensing Modulo Kr 280
Tahiti Condensing Modulo Kr 310
Tahiti Condensing Modulo Kr 340
WARM COMFORT
Standard
With GSM interface
With PC interface
CTTxx2SO1B
CTTxx2SV1B
Painted cabinet
rh
CTTxx2SG1B
lh
CTTxx2SH1B
CTTxx2SP1B
CTTxx2SY1B
Stainless steel cabinet
rh
CTTxx2SL1B
CTTxx2SQ1B
CTTxx2SW1B
lh
CTTxx2SM1B
CTTxx2SR1B
CTTxx2SX1B
Without cabinet
-
CTTxx2SN1B
CTTxx2ST1B
CTTxx2SZ1B
Painted cabinet
rh
CTTxx2SG1E
CTTxx2SO1E
CTTxx2SV1E
lh
CTTxx2SH1E
CTTxx2SP1E
CTTxx2SY1E
Stainless steel cabinet
rh
CTTxx2SL1E
CTTxx2SQ1E
CTTxx2SW1E
lh
CTTxx2SM1E
CTTxx2SR1E
CTTxx2SX1E
Without cabinet
-
CTTxx2SN1E
CTTxx2ST1E
CTTxx2SZ1E
Painted cabinet
rh
CTTxx2SG1H
CTTxx2SO1H
CTTxx2SV1H
lh
CTTxx2SH1H
CTTxx2SP1H
CTTxx2SY1H
Stainless steel cabinet
rh
CTTxx2SL1H
CTTxx2SQ1H
CTTxx2SW1H
lh
CTTxx2SM1H
CTTxx2SR1H
CTTxx2SX1H
Without cabinet
-
CTTxx2SN1H
CTTxx2ST1H
CTTxx2SZ1H
Painted cabinet
rh
CTTxx2SG2C
CTTxx2SO2C
CTTxx2SV2C
lh
CTTxx2SH2C
CTTxx2SP2C
CTTxx2SY2C
Stainless steel cabinet
rh
CTTxx2SL2C
CTTxx2SQ2C
CTTxx2SW2C
lh
CTTxx2SM2C
CTTxx2SR2C
CTTxx2SX2C
Without cabinet
-
CTTxx2SN2C
CTTxx2ST2C
CTTxx2SZ2C
Painted cabinet
rh
CTTxx2SG2F
CTTxx2SO2F
CTTxx2SV2F
lh
CTTxx2SH2F
CTTxx2SP2F
CTTxx2SY2F
Stainless steel cabinet
rh
CTTxx2SL2F
CTTxx2SQ2F
CTTxx2SW2F
lh
CTTxx2SM2F
CTTxx2SR2F
CTTxx2SX2F
Without cabinet
-
CTTxx2SN2F
CTTxx2ST2F
CTTxx2SZ2F
Painted cabinet
rh
CTTxx2SG2I
CTTxx2SO2I
CTTxx2SV2I
lh
CTTxx2SH2I
CTTxx2SP2I
CTTxx2SY2I
Stainless steel cabinet
rh
CTTxx2SL2I
CTTxx2SQ2I
CTTxx2SW2I
lh
CTTxx2SM2I
CTTxx2SR2I
CTTxx2SX2I
Without cabinet
-
CTTxx2SN2I
CTTxx2ST2I
CTTxx2SZ2I
Painted cabinet
rh
CTTxx2SG3B
CTTxx2SO3B
CTTxx2SV3B
lh
CTTxx2SH3B
CTTxx2SP3B
CTTxx2SY3B
Stainless steel cabinet
rh
CTTxx2SL3B
CTTxx2SQ3B
CTTxx2SW3B
lh
CTTxx2SM3B
CTTxx2SR3B
CTTxx2SX3B
Without cabinet
-
CTTxx2SN3B
CTTxx2ST3B
CTTxx2SZ3B
Painted cabinet
rh
CTTxx2SG3E
CTTxx2SO3E
CTTxx2SV3E
lh
CTTxx2SH3E
CTTxx2SP3E
CTTxx2SY3E
Stainless steel cabinet
rh
CTTxx2SL3E
CTTxx2SQ3E
CTTxx2SW3E
lh
CTTxx2SM3E
CTTxx2SR3E
CTTxx2SX3E
Without cabinet
-
CTTxx2SN3E
CTTxx2ST3E
CTTxx2SZ3E
78
Model
Tahiti Condensing Modulo Kr 360
ACCESSORIES FOR Ø 200 mm FLUE GAS OUTLET
Tahiti Condensing Modulo Kr 390
Tahiti Condensing Modulo Kr 420
Tahiti Condensing Modulo Kr 450
Tahiti Condensing Modulo Kr 480
Tahiti Condensing Modulo Kr 510
Standard
With GSM interface
With PC interface
Painted cabinet
rh
CTTxx2SG3G
CTTxx2SO3G
CTTxx2SV3G
lh
CTTxx2SH3G
CTTxx2SP3G
CTTxx2SY3G
Stainless steel cabinet
rh
CTTxx2SL3G
CTTxx2SQ3G
CTTxx2SW3G
lh
CTTxx2SM3G
CTTxx2SR3G
CTTxx2SX3G
Without cabinet
-
CTTxx2SN3G
CTTxx2ST3G
CTTxx2SZ3G
Painted cabinet
rh
CTTxx2SG3J
CTTxx2SO3J
CTTxx2SV3J
lh
CTTxx2SH3J
CTTxx2SP3J
CTTxx2SY3J
Stainless steel cabinet
rh
CTTxx2SL3J
CTTxx2SQ3J
CTTxx2SW3J
lh
CTTxx2SM3J
CTTxx2SR3J
CTTxx2SX3J
Without cabinet
-
CTTxx2SN3J
CTTxx2ST3J
CTTxx2SZ3J
Painted cabinet
rh
CTTxx2SG4C
CTTxx2SO4C
CTTxx2SV4C
lh
CTTxx2SH4C
CTTxx2SP4C
CTTxx2SY4C
Stainless steel cabinet
rh
CTTxx2SL4C
CTTxx2SQ4C
CTTxx2SW4C
lh
CTTxx2SM4C
CTTxx2SR4C
CTTxx2SX4C
Without cabinet
-
CTTxx2SN4C
CTTxx2ST4C
CTTxx2SZ4C
Painted cabinet
rh
CTTxx2SG4F
CTTxx2SO4F
CTTxx2SV4F
lh
CTTxx2SH4F
CTTxx2SP4F
CTTxx2SY4F
Stainless steel cabinet
rh
CTTxx2SL4F
CTTxx2SQ4F
CTTxx2SW4F
lh
CTTxx2SM4F
CTTxx2SR4F
CTTxx2SX4F
Without cabinet
-
CTTxx2SN4F
CTTxx2ST4F
CTTxx2SZ4F
Painted cabinet
rh
CTTxx2SG4I
CTTxx2SO4I
CTTxx2SV4I
lh
CTTxx2SH4I
CTTxx2SP4I
CTTxx2SY4I
Stainless steel cabinet
rh
CTTxx2SL4I
CTTxx2SQ4I
CTTxx2SW4I
lh
CTTxx2SM4I
CTTxx2SR4I
CTTxx2SX4I
Without cabinet
-
CTTxx2SN4I
CTTxx2ST4I
CTTxx2SZ4I
Painted cabinet
rh
CTTxx2SG5B
CTTxx2SO5B
CTTxx2SV5B
lh
CTTxx2SH5B
CTTxx2SP5B
CTTxx2SY5B
Stainless steel cabinet
rh
CTTxx2SL5B
CTTxx2SQ5B
CTTxx2SW5B
lh
CTTxx2SM5B
CTTxx2SR5B
CTTxx2SX5B
Without cabinet
-
CTTxx2SN5B
CTTxx2ST5B
CTTxx2SZ5B
IMPORTANT: when ordering, please specify the required Type of gas: Methane or Propane
79
CONDENSING BOILERS
CASCADE RIGS
TAHITI CONDENSING MODULO KR Basic non-wired control panel
Merlin V4 Control Unit
Includes the control unit alone, for controlling up to 4 generators (not wired). ON/OFF generator control.
Merlin V3 Control Unit
Includes the control unit alone, for controlling up to 6 generators (not wired). Complete generator management via OpenTherm. Model
Tahiti Condensing Modulo Kr 110
Tahiti Condensing Modulo Kr 140
ACCESSORIES FOR Ø 160 mm FLUE GAS OUTLET
Tahiti Condensing Modulo Kr 170
Tahiti Condensing Modulo Kr 220
Tahiti Condensing Modulo Kr 250
Tahiti Condensing Modulo Kr 280
Tahiti Condensing Modulo Kr 310
Tahiti Condensing Modulo Kr 340
WARM COMFORT
Version
Merlin V4
Merlin V3
Painted cabinet
rh
CTTxx2SA1B
CTTxx2SE1B
lh
CTTxx2SB1B
CTTxx2SF1B
Stainless steel cabinet
rh
CTTxx2SC1B
CTTxx2SI1B
lh
CTTxx2SD1B
CTTxx2SJ1B
Without cabinet
-
CTTxx2SS1B
CTTxx2SK1B
Painted cabinet
rh
CTTxx2SA1E
CTTxx2SE1E
lh
CTTxx2SB1E
CTTxx2SF1E
Stainless steel cabinet
rh
CTTxx2SC1E
CTTxx2SI1E
lh
CTTxx2SD1E
CTTxx2SJ1E
Without cabinet
-
CTTxx2SS1E
CTTxx2SK1E
Painted cabinet
rh
CTTxx2SA1H
CTTxx2SE1H
lh
CTTxx2SB1H
CTTxx2SF1H
Stainless steel cabinet
rh
CTTxx2SC1H
CTTxx2SI1H
lh
CTTxx2SD1H
CTTxx2SJ1H
Without cabinet
-
CTTxx2SS1H
CTTxx2SK1H
Painted cabinet
rh
CTTxx2SA2C
CTTxx2SE2C
lh
CTTxx2SB2C
CTTxx2SF2C
Stainless steel cabinet
rh
CTTxx2SC2C
CTTxx2SI2C
lh
CTTxx2SD2C
CTTxx2SJ2C
Without cabinet
-
CTTxx2SS2C
CTTxx2SK2C
Painted cabinet
rh
CTTxx2SA2F
CTTxx2SE2F
lh
CTTxx2SB2F
CTTxx2SF2F
Stainless steel cabinet
rh
CTTxx2SC2F
CTTxx2SI2F
lh
CTTxx2SD2F
CTTxx2SJ2F
Without cabinet
-
CTTxx2SS2F
CTTxx2SK2F
Painted cabinet
rh
CTTxx2SA2I
CTTxx2SE2I
lh
CTTxx2SB2I
CTTxx2SF2I
Stainless steel cabinet
rh
CTTxx2SC2I
CTTxx2SI2I
lh
CTTxx2SD2I
CTTxx2SJ2I
Without cabinet
-
CTTxx2SS2I
CTTxx2SK2I
Painted cabinet
rh
CTTxx2SA3B
CTTxx2SE3B
lh
CTTxx2SB3B
CTTxx2SF3B
Stainless steel cabinet
rh
CTTxx2SC3B
CTTxx2SI3B
lh
CTTxx2SD3B
CTTxx2SJ3B
Without cabinet
-
CTTxx2SS3B
CTTxx2SK3B
Painted cabinet
rh
CTTxx2SA3E
CTTxx2SE3E
lh
CTTxx2SB3E
CTTxx2SF3E
Stainless steel cabinet
rh
CTTxx2SC3E
CTTxx2SI3E
lh
CTTxx2SD3E
CTTxx2SJ3E
Without cabinet
-
CTTxx2SS3E
CTTxx2SK3E
80
Model
Tahiti Condensing Modulo Kr 360
ACCESSORIES FOR Ø 200 mm FLUE GAS OUTLET
Tahiti Condensing Modulo Kr 390
Tahiti Condensing Modulo Kr 420
Tahiti Condensing Modulo Kr 450
Tahiti Condensing Modulo Kr 480
Tahiti Condensing Modulo Kr 510
Version
Merlin V3
Painted cabinet
rh
CTTxx2SE3G
lh
CTTxx2SF3G
Stainless steel cabinet
rh
CTTxx2SI3G
lh
CTTxx2SJ3G
Without cabinet
-
CTTxx2SK3G
Painted cabinet
rh
CTTxx2SE3J
lh
CTTxx2SF3J
Stainless steel cabinet
rh
CTTxx2SI3J
lh
CTTxx2SJ3J
Without cabinet
-
CTTxx2SK3J
Painted cabinet
rh
CTTxx2SE4C
lh
CTTxx2SF4C
Stainless steel cabinet
rh
CTTxx2SI4C
lh
CTTxx2SJ4C
Without cabinet
-
CTTxx2SK4C
Painted cabinet
rh
CTTxx2SE4F
lh
CTTxx2SF4F
Stainless steel cabinet
rh
CTTxx2SI4F
lh
CTTxx2SJ4F
Without cabinet
-
CTTxx2SK4F
Painted cabinet
rh
CTTxx2SE4I
lh
CTTxx2SF4I
Stainless steel cabinet
rh
CTTxx2SI4I
lh
CTTxx2SJ4I
Without cabinet
-
CTTxx2SK4I
Painted cabinet
rh
CTTxx2SE5B
lh
CTTxx2SF5B
Stainless steel cabinet
rh
CTTxx2SI5B
lh
CTTxx2SJ5B
Without cabinet
-
CTTxx2SK5B
IMPORTANT: when ordering, please specify the required Type of gas: Methane or Propane
81
CONDENSING BOILERS
CASCADE RIGS
TAHITI CONDENSING MODULO KR Modules with cabinet D
A 630
350 200
462,4
2327 200 2280 160 2215 1911
462,4
B
M
300
G R
591 402 285 226
SC
SS 99 155 348
1555 1601
700
3161
1450
4717
50
R7
Modules without cabinet with rack (option) The rack is not compulsory, but it helps when positioning the thermal modules and the hydraulic collectors to the wall. C D A
G
M R
SC
SS
WARM COMFORT
82
CONDENSING BOILERS
CASCADE RIGS
146
446
1670
1770
Rack (optional)
381
430
1211
497
Legenda DESCRIPTION
CONNECTIONS
M
Flow
DN 80 PN 6
R
Return
DN 80 PN 6
G
Gas
DN 50 PN 6
SC
Condensate drain
Ø 50
SS
Purge drain
G1½F
The modular heat generators are supplied with the flue gas discharge ducts for each boiler. The flue gas collectors, the extension cords, the sealing caps for flue gas collectors and every other component are sold separately as accessories.
A Flue gas collectors
B Connection extension cord (for cabinets)
C Connection extension cord (without cabinets)
D Sealing cap
Ø 160 mm
0COLLFUM00
0PROLUNG11
0PROLUNG12
0SCARCON01
Ø 200 mm
0COLLFUM01
0PROLUNG14
0PROLUNG15
0SCARCON02
Diameter piping equal to 160 millimetres are used for outputs up to 340 kW. For greater outputs, use 200 millimetre diameter piping.
83
TAHITI CONDENSING MODULO KR TECHNICAL SPECIFICATIONS
KR 110
KR 140
KR 170
KR 220
KR 250
KR 280
KR 310
Nominal heat input
kW
110
140
170
220
250
280
310
Nominal heat output (80/60°C)
kW
107.0
136.2
165.4
214.0
243.2
272.4
301.6
Nominal heat output (50/30°C)
kW
117.6
149.2
180.8
235.2
266.8
298.4
330.0
Reduced heat output
kW
14.5
14.5
21.0
14.5
14.5
14.5
14.5
Reduced heat output (80/60°C)
kW
14.1
14.1
20.3
14.1
14.1
14.1
14.1
Reduced heat output (50/30°C)
kW
15.7
15.7
22.6
15.7
15.7
15.7
15.7
Efficiency at100% (80/60°C)
%
97.3
97.3
97.3
97.3
97.3
97.3
97.3
Efficiency at100% (50/30°C)
%
107.0
106.7
106.4
107.0
106.9
106.7
106.6
Efficiency at 30% (30°C on return)
%
108.9
108.7
108.5
108.9
108.8
108.7
108.6
Efficiency at 30% (47°C on return)
%
103.3
102.9
102.4
103.3
103.1
102.9
102.6
Efficiency at reduced output (80/60°C)
%
97.0
97.2
97.3
97.0
97.1
97.2
97.2
Efficiency at reduced output (50/30°C)
%
108.1
107.9
107.7
108.1
108.0
107.9
107.8
Central heating T setting range
°C
20÷80
20÷80
20÷80
20÷80
20÷80
20÷80
20÷80
Maximum CH temperature
°C
80
80
80
80
80
80
80
Maximum operating pressure
bar
6
6
6
6
6
6
6
Maximum height (with cabinet and flue gas discharge piping Ø 200)
mm
2327
2327
2327
2327
2327
2327
2327
Maximum cabinet height
mm
1900
1900
1900
1900
1900
1900
1900
Depth (with cabinet)
mm
700
700
700
700
700
700
700
Width (with cabinet)
mm
1555
1555
1555
3161
3161
3161
3161
Maximum height (without cabinet and with flue gas discharge piping Ø 200)
mm
2225
2225
2225
2225
2225
2225
2225
Depth (Without cabinet)
mm
583
583
583
583
583
583
583
Width (without cabinet, with hydraulic separator)
mm
1453
1453
1453
2688
2688
2688
2688
Total weight (with cabinet and packaging)
kg
464
488
512
864
888
912
936
Weight (without cabinet – weight of supply packing)
kg
242
266
290
420
444
468
492
Number of cabinets or wall racks
n°
1
1
1
2
2
2
2
mm
160
160
160
160
160
160
160
Flue gas discharge piping diameter
WARM COMFORT
84
TECHNICAL SPECIFICATIONS
KR 340
KR 360
KR 390
KR 420
KR 450
KR 480
KR 510
Nominal heat input
kW
340
360
390
420
450
480
510
Nominal heat output (80/60°C)
kW
330.8
350.2
379.4
408.6
437.8
467.0
496.2
Nominal heat output (50/30°C)
kW
361.6
384.4
416.0
447.6
479.2
510.8
542.4
Reduced heat output
kW
21.0
14.5
14.5
14.5
14.5
14.5
21.0
Reduced heat output (80/60°C)
kW
20.3
14.1
14.1
14.1
14.1
14.1
20.3
Reduced heat output (50/30°C)
kW
22.6
15.7
15.7
15.7
15.7
15.7
22.6
Efficiency at100% (80/60°C)
%
97.3
97.3
97.3
97.3
97.3
97.3
97.3
Efficiency at100% (50/30°C)
%
106.4
106.9
106.8
106.7
106.6
106.5
106.4
Efficiency at 30% (30°C on return)
%
108.5
108.8
108.8
108.7
108.6
108.6
108.5
Efficiency at 30% (47°C on return)
%
102.4
103.2
103.0
102.9
102.7
102.6
102.4
Efficiency at reduced output (80/60°C)
%
97.3
97.1
97.1
97.2
97.2
97.3
97.3
Efficiency at reduced output (50/30°C)
%
107.7
108.0
108.0
107.9
107.8
107.8
107.7
Central heating T setting range
°C
20÷80
20÷80
20÷80
20÷80
20÷80
20÷80
20÷80
Maximum CH temperature
°C
80
80
80
80
80
80
80
Maximum operating pressure
bar
6
6
6
6
6
6
6
Maximum height (with cabinet and flue gas discharge piping Ø 200)
mm
2327
2327
2327
2327
2327
2327
2327
Maximum cabinet height
mm
1900
1900
1900
1900
1900
1900
1900
Depth (with cabinet)
mm
700
700
700
700
700
700
700
Width (with cabinet)
mm
3161
4717
4717
4717
4717
4717
4717
Maximum height (without cabinet and with flue gas discharge piping Ø 200)
mm
2225
2225
2225
2225
2225
2225
2225
Depth (Without cabinet)
mm
583
583
583
583
583
583
583
Width (without cabinet, with hydraulic separator)
mm
2688
3923
3923
3923
3923
3923
3923
Total weight (with cabinet)
kg
960
1288
1312
1336
1360
1384
1408
Weight (without cabinet – weight of supply packing)
kg
516
622
646
670
694
718
742
Number of cabinets or wall racks
n°
2
3
3
3
3
3
3
mm
160
200
200
200
200
200
200
Flue gas discharge piping diameter
85
CONDENSING BOILERS
CASCADE RIGS
MAUI kr 115 - 280
WARM COMFORT
86
➲
Aluminium alloy, silicon and magnesium primary exchanger
➲
Wide modulation range
➲
Compact size
➲
Cascade installation possible with the standard control panel
➲
Extremely low noise level
➲
User - friendly interface
MURALI A CONDENSING BOILERS CONDENSAZIONE
FLOOR-STANDING CONDENSING HEAT GENERATORS FOR CENTRAL THERMAL PLANT
• • • • • • • • • • •
Display
• • • •
Heat output: 116.1 to 285.5 kW; NOx Class 5 Energy efficiency ★★★★ (Directive 92/42/EC) Wide modulation range (21 to 100% heat output) Ratings: at 100% load with a temperature 80/60 °C = more than 97%; at 30% load with a temperature 30 °C on return = 107.5% Aluminium alloy, silicon and magnesium heat exchanger with low water content Modulating, fully pre-mixed gas burner Control panel with alphanumeric display and programming buttons Electronics suitable for remote control systems 0-10 V control in temperature for regulation Thermoregulation with external probe (optional) DHW production through coupling with remote hot water storage managed by the boiler electronic board or fault and shut-down remote signal Connections to zone controls via Open Therm PWM primary pump management Innovative 5+1 parameter climate control Possibility of cascade installations with a single bus connection (no need for external regulators)
Model
Code
Nominal heat output (50/30 °C) kW
Efficiency at 100% (50/30°C)
Gross weight (kg)
MAUI KR 115
CMTxx2RR1C
116.1
102.7 %
185.00
MAUI KR 150
CMTxx2RR1F
156.2
104.1 %
200.00
MAUI KR 200
CMTxx2RR2A
207.8
103.9 %
250.00
MAUI KR 240
CMTxx2RR2E
243.9
103.8 %
265.00
MAUI KR 280
CMTxx2RR2I
285.5
103.8 %
285.00
87
MAUI KR 115-280 SINGLE BOILER CONNECTION CENTRE DISTANCES AND DIMENSIONS D
C E
L
M
F
M
B H
Ø Ø
GAS
GAS
R
R G A
SC
SC M - CH flow
R - CH return
P
SC - Condensate drain
Single boiler dimension table Model
LxHxD mm
M ø
R ø
SC mm
A mm
B mm
C mm
D mm
E mm
F mm
GAS ø
G mm
Ø mm
Maui KR 115
640x1200x1115
2” M
2” M
25
400
728
175
848
279
363
1” ½
624
150
Maui KR 150
640x1200x1115
2” M
2” M
25
400
728
175
848
279
363
1” ½
624
150
Maui KR 200
640x1200x1335
2” M
2” M
25
400
728
245
1088
279
363
1” ½
624
200
Maui KR 240
640x1200x1335
2” M
2” M
25
400
728
245
1088
279
363
1” ½
624
200
Maui KR 280
640x1200x1335
2” M
2” M
25
400
728
245
1088
279
363
1” ½
624
200
CASCADE BOILERS CENTRE DISTANCES AND CONNECTIONS pozzetto per sonda valvola di Holder for fuel cut-off valve intercettazione combustibile (non fornita) probe (not supplied)
pozzetto per Thermometer termometro ISPESL holder 825
A
1100
B
Sm M2
M1 MI
728
1460
MI
Gas
RI
400
RI
M1..4 R1.. 4 MI RI F
WARM COMFORT
F
R2
R1
Boiler flow (Ø 2” M) Boiler return (Ø 2” M) System flow (Ø 4” with flange) System return (Ø 4” with flange) Y-shaped filter must be compulsorily fitted on system return (use a sludge remover in case of very dirty systems)
88
Boiler models Modelli caldaia 115
150115 200 150 240 200 280 240
A
A 1180
1180
1250
1250
B
B 915
915
985
985
280
ACCESSORIES FOR SINGLE BOILER Article
Description
MODULATING CIRCULATION PUMP FOR MAUI KR 115/280
CONDENSATE NEUTRALIZING FILTER (for boilers with max. output 350 kW) PRIMARY CIRCUIT CONTROL KIT WITHOUT HYDRAULIC SEPARATOR (WITHOUT PUMP) 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cutoff valve, Hydraulic pipes and connections. note: a hydraulic separator or a plate exchanger must be compulsorily fitted. PRIMARY CIRCUIT CONTROL KIT WITH HYDRAULIC SEPARATOR (WITHOUT PUMP) DN 100 Hydraulic separator, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections
PRIMARY CIRCUIT CONTROL KIT FOR MAUI KR 115 WITH PLATE EXCHANGER (WITHOUT PUMP) Heat exchanger for boiler model115, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections.
Code
Article
0CIRCTOP03
0FILNECO01
0KGESTCP09
0KGESTCP10
Description
Code
PRIMARY CIRCUIT CONTROL KIT FOR MAUI KR 240 WITH PLATE EXCHANGER (WITHOUT PUMP) Heat exchanger for boiler model 240, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections.
0KGESTCP14
PRIMARY CIRCUIT CONTROL KIT FOR MAUI KR 280 WITH PLATE EXCHANGER (WITHOUT PUMP) Heat exchanger for boiler model 280, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections.
0KGESTCP15
ZONE KIT FOR MAUI (MANAGING 2 LOW-TEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE06
ZONE KIT FOR MAUI WITH PROGRAMMING UNIT INTERFACE (MANAGING 2 LOW-TEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE07
Ø 150/160 REDUCER
0RIDUZIO20
SECONDARY CIRCUIT TEMPERATURE PROBE
0SONDAES05
Hot water storage temperature probe
0SONDAES06
EXTERNAL PROBE
0SONDAES07
0KGESTCP11
PRIMARY CIRCUIT CONTROL KIT FOR MAUI KR 150 WITH PLATE EXCHANGER (WITHOUT PUMP) Heat exchanger for boiler model150, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections.
0KGESTCP12
PRIMARY CIRCUIT CONTROL KIT FOR MAUI KR 200 WITH PLATE EXCHANGER (WITHOUT PUMP) Heat exchanger for boiler model 200, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel, Automatic bleeding cut-off valve, Hydraulic pipes and connections.
0KGESTCP13
89
CONDENSING BOILERS
COMMERCIAL FLOOR STANDING CONDENSING BOILERS
MAUI KR 115-280 ACCESSORIES FOR CASCADE BOILERS Article
Description
MODULATING PUMP FOR MAUI KR 115/280
Article
0CIRCTOP03
CONDENSATE NEUTRALIZING FILTER (for boilers with max. output 350 kW)
0FILNECO01
CONDENSATE NEUTRALIZING FILTER (for boilers with max. output 1500 kW)
0FILNECO02
KIT FOR 4 CASCADE BOILERS WITH HYDRAULIC SEPARATOR (WITHOUT CIRCULATION PUMPS) 330 mm hydraulic separator with flange, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel (1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
WARM COMFORT
Code
Description
Code
KIT FOR 4 CASCADE BOILERS (WITHOUT CIRCULATION PUMPS) 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel (1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
0KCASCAT05
ZONE KIT FOR MAUI (MANAGING 2 LOW-TEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE06
ZONE KIT FOR MAUI WITH PROGRAMMING UNIT INTERFACE (MANAGING 2 LOW-TEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE07
SECONDARY CIRCUIT TEMPERATURE PROBE
0SONDAES05
HOT WATER STORAGE TEMPERATURE PROBE
0SONDAES06
0KCASCAT00
KIT FOR 4 CASCADE BOILERS WITH HYDRAULIC SEPARATOR (WITHOUT CIRCULATION PUMPS) 330 mm hydraulic separator with flange, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel ( 1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
0KCASCAT01
KIT FOR 4 CASCADE BOILERS WITH HYDRAULIC SEPARATOR (WITHOUT CIRCULATION PUMPS) 330 mm hydraulic separator with flange, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel (1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
0KCASCAT02
KIT FOR 2 CASCADE BOILERS (WITHOUT CIRCULATION PUMPS) 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel ( 1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
0KCASCAT03
KIT FOR 3 CASCADE BOILERS (WITHOUT CIRCULATION PUMPS) 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, 5-bar Safety valve, 18-litre Expansion vessel (1 for each boiler), Automatic bleeding cut-off valve, Hydraulic pipes and connections, Boiler support structure
0KCASCAT04
90
TECHNICAL SPECIFICATIONS
KR 115
Fuel
KR 150
KR 200
KR 240
KR 280
G20 (20 mbar) - G31 (37 mbar)
Type of device
B23. B33. C43. C53. C63. C83
Nominal heat input (Qn)
kW
Minimum heat input (Qmin)
kW
21.0
30.0
35.5
42.5
49.5
Nominal heat input (80-60°C) (Pn)
kW
109.7
146.7
196.0
229.8
269.2
Nominal heat input (50-30°C)
kW
116.1
156.2
207.8
243.9
285.5
Minimum heat output (80-60°C) (Pmin)
kW
20.0
29.0
34.7
41.5
48.3
Useful efficiency at Pn (80-60°C)
%
97.1
97.8
98
97.8
97.9
Useful efficiency at Pn min (80-60°C)
%
95
96.5
97.7
97.6
97.5
Useful efficiency at Pn (50-30°C)
%
102.7
104.1
103.9
103.8
103.8
Useful efficiency at 30% (return 30°C) Max gas consumption
% Methane m3/h Propane
Minimum gas consumption
113.0
113.0
200.0
235.0
275.0
107.6
107.5
107.5
107.5
107.5
11.96
15.87
21.16
24.87
29.1
kg/h
8.78
11.66
15.54
18.26
21.37
Methane m3/h
2.22
3.17
3.76
4.5
5.24
Propane
1.63
2.33
2.76
3.30
3.85
kg/h
Flue gas temperature (80-60°C) at nominal heat output
°C
65 - 70
Flue gas temperature (80-60°C) at minimum heat output
°C
60 - 65
Flue gas temperature(50-30°C) at minimum heat output
°C
40 - 45
Flue mass flow at nominal heat output (80-60°C)
g/s
49.1
64.6
86.1
99.5
110.8
Flue mass flow at nominal heat output (80-60°C)
g/s
9.80
16.10
16.30
19.10
21.50
Maximum condensate production
l/h
15.00
19.00
25.00
30.00
36.00
CO2 max/min (G20) (average values)
%
9.3/9.1
CO2 max/min (G31) (average values)
%
10.6/10.3
CO
ppm
25.0
30.0
35.0
20.0
28.0
NOx
ppm
15.0
20.0
18.0
18.0
18.0
NOx emission class
-
5
5
5
5
5
Power absorption
W
225
260
320
320
320
Input voltage
Volt ~ Hz
Protection degree
IP
CH max pressure
bar
6
Maximum operating temperature
°C
90
CH water content
l
Water side pressure loss at ΔT 20°
mbar
Flow/return maximum ∆T
°C
Water flow at ΔT 20°C
m3/h
Water flow at ΔT 10
220/240 ~ 50/60 X0D
15.3
18
22.9
25.6
28.4
80
80
90
90
100
4.86
6.45
8.6
10.11
11.83
m /h
9.72
12.9
17.2
20.21
23.65
Chimney coupling
Ø
150
150
200
200
200
Fitting air
Ø
100
35
3
FLue gas outlet
Total available head (flue gas outlet + air intake) Revolution number Min ÷ Max Frequency Min ÷ Max Fan revolution number Min ÷ Max
Pa Methane rev/min. Hz Propane rev/min.
Frequency Min ÷ Max
Hz
Width
mm
Depth (chimney included)
mm
320
233
100
180
85
1665 ÷ 7400
1650 ÷ 6250
1230 ÷ 5600
1320 ÷ 5800
1300 ÷ 5800
55.5 ÷ 246.7
55 ÷ 208.3
61.5 ÷ 280
66 ÷ 290
65 ÷ 290
1665 ÷ 7400
1650 ÷ 6250
1230 ÷ 5600
1320 ÷ 5800
1300 ÷ 5800
55.5 ÷ 246.7
55 ÷ 208.3
61.5 ÷ 280
66 ÷ 290
65 ÷ 290
1115
1115
1335
1335
1335
640
Height
mm
Net weight
Kg
175.00
190.00
240.00
1200 255.00
275.00
Gross weight
Kg
185.00
200.00
250.00
265.00
285.00
91
CONDENSING BOILERS
COMMERCIAL FLOOR STANDING CONDENSING BOILERS
MAUI kr 340 - 620
WARM COMFORT
92
➲
Aluminium alloy, silicon and magnesium primary exchanger
➲
Wide modulation range
➲
Compact size
➲
Cascade installation possible with the standard control panel
➲
Extremely low noise level
➲
User-friendly interface
MODULI A CONDENSING BOILERS CONDENSAZIONE
MODULAR CONDENSING FLOOR-STANDING HEAT GENERATORS FOR HEAT POWER plants
• • • • • • • • • • • • • • • • • • • Display
• •
Nominal heat output from 320 to 620 kW (50/30 °C) NOx class: 5 Energy efficiency ★★★★ (Directive 92/42/EC) Wide modulation range (18 to 100% heat output) Independently adjustable maximum heating and hot water power levels Aluminium alloy, silicon and magnesium heat exchanger with low water content Modulating, fully pre-mixed gas burner Possibility of moving the boiler’s control panel to the side facing away from the wall Openable front casing, with no need for tools Suction unit slide for maximum ease of maintenance Presence of a clapper valve in the mixing unit to prevent flue gas leakage in cascade systems Possibility of cascade installation with a single bus connection (no need for external regulators) Electronics suitable for remote control systems Innovative 5+1 parameter climate control 0-10 V temperature regulation control Connections to zone controls via OpenTherm PWM primary pump management Management of a secondary DHW circulation pump/deviating valve DHW production through coupling with remote hot water storage managed by the boiler electronic board or fault and shut-down remote signal Remote dry contact for boiler alarms Powered plug or contact (230 VAC) for I.S.P.E.S.L./I.N.A.I.L. block
Model
Code
Nominal heat output (50/30 °C) kW
Efficiency at100% (50/30°C)
Gross weight (kg)
LxHxD
MAUI KR 340
CMTxx2RR3E
340.2
106.3 %
510.00
1894 x 1525 x 864
MAUI KR 410
CMTxx2RR4B
412.6
105.8 %
540.00
1894 x 1525 x 864
MAUI KR 480
CMTxx2RR4I
487.6
106.0 %
570.00
1894 x 1525 x 864
MAUI KR 550
CMTxx2RR5F
551.2
106.0 %
600.00
1894 x 1525 x 864
MAUI KR 620
CMTxx2RR6C
620.1
106.0 %
635.00
1894 x 1525 x 864
93
MAUI KR 340 - 620 SINGLE BOILER CONNECTION CENTRE DISTANCES AND DIMENSIONS M CH flow (DN 100 PN 16) R CH return (DN 100 PN 16) SC Condensate drain A Air intake (DN 160) G Gas fitting (G 2” ½) SF Flue gas outlet coupling (DN 250)
ACCESSORIES FOR SINGLE BOILER Article
Description
Code
MODULATING CIRCULATION PUMP FOR MAUI 340-620 managed by the boiler via a PWM signal, DN 100
0CIRCTOP04
CONDENSATE NEUTRALIZING FILTER (for boilers with max. output 1500 kW)
0FILNECO02
MAIN CIRCUIT MANAGEMENT KIT WITH HYDRAULIC SEPARATOR AND CIRCULATION PUMP Hydraulic separator DN 300, Modulating circulation pump, 0-120°C Thermometer, Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, Safety valve 5 bar, 25-litre Expansion vessel, Automatic bleeding cut-off valve
Article
Description
AIR FILTER KIT
0KGESTCP16
Code
0KITFILT03
ZONE KIT FOR MAUI (MANAGING 2 LOWTEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE06
ZONE KIT FOR MAUI WITH PROGRAMMING UNIT INTERFACE (MANAGING 2 LOWTEMPERATURE ZONES and 1 HIGH-TEMPERATURE ZONE)
0KITZONE07
SECONDARY CIRCUIT TEMPERATURE PROBE
0SONDAES05
HOT WATER STORAGE TEMPERATURE PROBE
0SONDAES06
EXTERNAL PROBE
0SONDAES07
INAIL SAFETY DEVICES STUB KIT
Thermometer 0-120°C,Pressure gauge with 3-way cock, 100 °C Safety thermostat, Manual reset lock pressure switch, Safety valve 5 bar.
WARM COMFORT
0KGESTCP17
HYDRAULIC SEPARATOR KIT FOR MAUI KR 340/620 Hydraulic separator DN 300, Hydraulic separator support
0KGESTCP18
ELBOWS KIT FOR MAUI KR 340/620 Elbows with flanged couplings to fix the Hydraulic separator at an angle of 90° with respect to the boiler
0KGESTCP19
94
TECHNICAL SPECIFICATIONS
340
410
480
Fuel
550
620
G20 (20 mbar)
Type of device
B23p. C43. C53. C63. C83
Nominal heat input (Qn)
kW
320.0
390.0
460.0
520.0
585.0
Minimum heat input (Qmin)
kW
57.0
69.0
81.0
92.0
104.0
Nominal heat input (80-60°C) (Pn)
kW
313.6
383.0
451.7
510.6
574.5
Nominal heat input (50-30°C)
kW
340.2
412.6
487.6
551.2
620.1 100.8
Minimum heat output (80-60°C) (Pmin)
kW
55.2
66.9
79.4
89.0
Useful efficiency at Pn (80-60°C)
%
98
98.2
98.2
98.2
98.2
Useful efficiency at Pn min (80-60°C)
%
96.9
97
98
96.7
96.9
Useful efficiency at Pn (50-30°C)
%
106.3
105.8
106.0
106.0
106.0
%
109.1
107.9
108.9
107.8
107
Max gas consumption (G20)
Useful efficiency at 30% (return 30°C)
m3/h
35.621
41.784
49.208
54.978
62.1
Min gas consumption (G20)
m3/h
5.997
7.512
8.679
9.924
11.258
Flue gas temperatur (80-60°C) at nominal heat output
°C
61.30
60.70
62.30
63.70
62.60
Flue gas temperatur(80-60°C) at minimum heat output
°C
53.50
55.00
55.10
54.00
55.50
Flue gas temperatur(50-30°C) at nominal heat output
°C
41.6
42.9
40.8
41.5
41.4
Flue gas temperatur (50-30°C) at minimum heat output
°C
28.6
29.1
29.3
29.3
29.5
Flue mass flow at nominal heat output (80-60°C)
g/s
144.70
176.90
203.90
232.80
273.70
Flue mass flow at minimum heat output (80-60°C)
g/s
24.80
32.10
36.30
42.90
49.10
Maximum condensate production
l/h
27.60
34.70
42.80
51.20
54.90
CO2 max/min (G20) CO2 max/min (G20)
%
9.7/9.5
9.4/9.3
9.5/9.4
9.4/9.2
9.4/9.1
ppm
76/12
67/9
82/15
79/9
57/5
NOx
51.0
ppm
52.6
37.2
64.8
52.7
NOx emission class
-
5
5
5
5
5
Power absorption
W
500
563
771
658
689
Input voltage
Volt ~ Hz
220/240 ~ 50/60
Protection degree
IP
X0D
CH max pressure
bar
6
Maximum operating temperature
°C
85
CH water content Water side pressure loss at ΔT 20° Flow/return maximum ∆T
l
45
50.6
56.3
61.9
67.6
mbar
85.14
81.31
79.58
76.04
75.32
°C
35
Water flow at ΔT nom. 20°C
m3/h
13.773
16.635
19.831
21.848
24.837
Water flow at ΔT 15
3
m /h
18.364
22.18
26.441
29.131
33.116
Combustion chamber backpressure: Switching on
mbar
0.8
1.26
0.95
0.85
0.9
Combustion chamber backpressure: Minimum
mbar
0.14
0.12
0.11
0.11
0.12
Combustion chamber backpressure: Maximum
mbar
3.3
3.2
3.1
2.8
2.8
Air inlet speed at nominal input
m/s
6.2
7.71
9.4
8.1
12.4
Air inlet flow at nominal input
m3/h
448.766
558.062
680.387
586.279
897.085
Air inlet speed at minimum input
m/s
0.2
0.81
0.9
1.2
1.5
Air inlet flow at minimum input
m3/h
14.476
58.629
65.143
86.856
108.573
Chimney coupling
Ø
Air intake coupling
Ø
Total available head (flue gas outlet + air intake)
Pa
170
170
170
170
120
rev/min.
5000
5200
5700
5350
4100
Fan revolution number at nominal input
250 160
Fan revolution number at minimum input
rev/min.
1150
1200
1250
1200
900
Fan revolution number during switching on
rev/min.
2450
2400
2400
2400
1750
Width
mm
864
Depth (chimney included)
mm
1894
Height
mm
1525
Net weight
Kg
410.00
440.00
470.00
500.00
535.00
Gross weight
Kg
510.00
540.00
570.00
600.00
635.00
95
CONDENSING BOILERS
COMMERCIAL FLOOR STANDING CONDENSING BOILERS
STANDARD BOILERS
ATMOSPHERIC BOILERS
WALL-HUNG BOILERS
97
ITACA CTFS mono-thermal
➲ ➲ ➲
Touch screen user interface
HHH efficiency in DHW “comfort” mode Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Controls to manage three different types of solar thermal systems fitted as standard (solar probe is optional)
➲
26-plate DHW heat exchanger
➲
Boiler hydraulic replacement kit
Available heat outputs:
24 kW
28 kW
Pre-set to run on Methane or LPG
WARM COMFORT
98
32 kW
CALDAIE
• Mono-thermal heat exchanger • 26-plate stainless steel DHW heat exchanger • 3-speed pump with integrated air purging device • Integrated hydraulic assembly including: three-way valve, automatic bypass, safety valve, pressure transducer, unloading tap, connection to the expansion vessel • Automatic or manual primary circuit filling system • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Integrated safety and modulation electronic board • Virtual room temperature control with weather compensation via external temperature probe (option) • Management of high- and low-temperature heating zones via electric board (option) • Energy efficiency marking (92/42/EC): ★★★ • DHW “Comfort” function : ★★★
Model
Type of gas
Code
ITACA CTFS 24
METHANE
CIBxx2CA24
sealed chamber
LPG
CIBxx3CA24
ITACA CTFS 28
METHANE
CIBxx2CA28
sealed chamber
LPG
CIBxx3CA28
ITACA CTFS 32
METHANE
CIBxx2CA32
LPG
CIBxx3CA32
sealed chamber
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
23.7
93.0 %
38.50
28.6
93.7 %
39.00
30.8
93.4 %
39.50
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit.
99
ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water, sealed COMBUSTION CHAMBER, A SPECIAL KIT CAN BE SUPPLIED IN ORDER TO ALLOW FOR INSTALLATION OUTDOORS
itaca ctfs Article
750
856
Dimensions and connection centre distances
315
420
Description
Code
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Gas and water tap kit
0KITRUBI04
Room temperature probe
0KITSAMB00
Solar connection kit (for combi boilers)
0KITSOLC07
Connection kit for complex solar systems
0KITSOLC08
Baxi/Itaca replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Itaca replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Immergas/ Itaca replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Itaca replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Tahiti/ Itaca replacement kit
0KITSOST13
0KITSOST14
210
C M
R
121
23 10
31
F
132
G
76
60 62
67
82
73
botton view
M CH flow (¾”) C DHW outlet (½”) G Gas inlet (½”)
top view
F Cold water inlet (½”) R CH return (¾”)
ACCESSORIES Article
WARM COMFORT
Description
Code
Air-intake/flue gas coaxial connection for type B22 installation
0ATTCOVE03
Pipes and taps cover
0COPETUB03
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
Remote control
0CREMOTO04
Electric zone kit with external probe
0KITZONE05
Fixing template (metal)
0DIMMECO11
Standard split pipe kit
0SDOPPIA11
Wall spacer ki
0DISTANZ00
“Plus” split pipe kit (0.5 meter long pipes)
0SDOPPIA12
Ø 100/60 mm, 1 metre type “A” coaxial kit
0KITCONC00
External probe
0SONDAES01
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE03
Temperature probe for solar heating plants
PSPTMILL00
Protection kit for outdoor installation, for condensing boilers
0KITCOPE04
100
TECHNICAL SPECIFICATIONS
CTFS 24
CTFS 28
CTFS 32
-
11.0
13.0
15.0
Nominal heat input
kW
25.5
30.5
33
Reduced heat input
kW
12.5
13.5
16
Nominal heat output
kW
23.7
28.6
30.8
Reduced heat output
kW
11.1
12.0
14.3
Useful efficiency at nominal heat input
%
93.0
93.7
93.4
Useful efficiency at 30%
%
90.2
90.6
91.0
Casing heat loss with burner on at nominal heat input
%
1.05
0.76
1.37
Casing heat loss with burner off
%
0.26
0.20
0.20
Chimney heat loss with burner on at nominal heat input
%
5.97
5.54
5.23
No. nozzles
Energy efficiency marking (92/42/EC)
-
★★★
★★★
★★★
CH maximum working pressure
bar
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
35-78
35-78
35-78
Expansion vessel capacity
l
7
7
7
Consumption at nominal heat output (CH)
Methane
m3/h
2.70
3.23
3.49
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
2.37
2.56
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
2.41
2.60
Energy efficiency marking for DHW production according to EN 13203-1
-
★★★
★★★
★★★
DHW maximum pressure
bar
6.0
6.0
6.0
DHW minimum pressure
bar
0.5
0.5
0.5
DHW nominal flow ∆T 30°C
l/min
11.6
14.2
15.1
DHW minimum heat input
l/min
3.0
3.0
3
DHW maximum working temperature
°C
62
62
62
DHW temperature range
°C
35-57
35-57
35-57
Air-flue ΔT at nominal heat input
°C
95.0
101.0
105.0
Flue gas flow at nominal heat input
g/s
15.44
17.29
17.80
CO2 at nominal heat input
Methane
%
6.1
7.0
7.4
CO2 at nominal heat input
Propane
%
6.7
7.7
8.4
CO2 at nominal heat input
Butane
%
7.0
8.0
8.7
Supply pressure
Methane
mbar
13-20
13-20
13-20
Supply pressure
Propane
mbar
37
37
37
Supply pressure
Butane
mbar
28-30
28-30
28-30
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
122
134
134
Electric protection rating
-
IPX5D
IPX5D
IPX5D
Gas fitting
-
G½
G½
G½
CH fittings
-
G¾
G¾
G¾
DHW fittings
-
G½
G½
G½
Coaxial air intake/flue gas duct diameter
100/60
100/60
100/60
Split air intake/flue gas duct diameter
80+80
80+80
80+80
Power supply voltage/frequency
LxHxD
420x750x315
mm
Net weight
kg
35.00
35.50
36.00
Gross weight
kg
38.50
39.00
39.50
101
ATMOSPHERIC BOILERS
WALL-HUNG COMBI BOILERS
itaca RTFS mono-thermal
➲
Touch screen user interface
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Controls to manage three different types of solar thermal systems fitted as standard (solar probe is optional)
➲
Time control of hot water storage regeneration
➲
Boiler hydraulic replacement kit
Available heat outputs:
24 kW
28 kW
Pre-set to run on Methane or LPG
WARM COMFORT
102
32 kW
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas boiler, heating only, sealed COMBUSTION CHAMBER
• Mono-thermal heat exchanger • 3-speed pump with integrated air purging device • Integrated hydraulic assembly including: automatic by-pass, safety valve, pressure transducer, unloading tap, connection to the expansion vessel • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Integrated safety and modulation electronic board • Virtual room temperature control with weather compensation via external temperature probe (option) • Management of high- and low-temperature heating zones via electric board (option) • Energy efficiency marking (92/42/EC): ★★★
Model
Type of gas
ITACA RTFS 24
Code
METHANE
CIBxx2RA24
sealed chamber
LPG
CIBxx3RA24
ITACA RTFS 28
METHANE
CIBxx2RA28
sealed chamber
LPG
CIBxx3RA28
ITACA RTFS 32
METHANE
CIBxx2RA32
LPG
CIBxx3RA32
sealed chamber
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
23.7
93.0 %
35.50
28.6
93.7 %
36.50
30.8
93.4 %
37.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit.
103
itaca rtfs Article
Description
Code
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
121
185 154 131
Dimensions and connection centre distances
750
76 60 62 67 82 73
0KITRUBI04
Room temperature probe
0KITSAMB00
Connection kit for complex solar systems
0KITSOLC08
Hot water storage temperature probe
0KITSOND00
Baxi/Itaca replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Itaca replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Immergas/ Itaca replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Itaca replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Itaca replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Tahiti/ Itaca replacement kit
0KITSOST13
0KITSOST14
210 135
92
47
132
147
Gas and water tap kit
420
315
F
147
M
210 135 132
G
92
121
185 154 131
47
R
76 122 67 82 73 botton view
G Gas inlet (½”) M CH flow (¾”)
top view
F Cold water inlet (½”) R CH return (¾”)
ACCESSORIES Article
WARM COMFORT
Description
Code
Air-intake/flue gas coaxial connection for type B22 installation
0ATTCOVE03
Pipes and taps cover
0COPETUB03
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
Remote control
0CREMOTO04
Electric zone kit with external probe
0KITZONE05
Fixing template (metal)
0DIMMECO11
Standard split pipe kit
0SDOPPIA11
Wall spacer ki
0DISTANZ00
“Plus” split pipe kit (0.5 meter long pipes)
0SDOPPIA12
Ø 100/60 mm, 1 metre type “A” coaxial kit
0KITCONC00
External probe
0SONDAES01
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE03
Temperature probe for solar heating plants
PSPTMILL00
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE04
104
TECHNICAL SPECIFICATIONS
RTFS 24
RTFS 28
RTFS 32
-
11.0
13.0
15.0
Nominal heat input
kW
25.5
30.5
33
Reduced heat input
kW
12.5
13.5
16
Nominal heat output
kW
23.7
28.6
30.8
Reduced heat output
kW
11.1
12.0
14.3
Useful efficiency at nominal heat input
%
93.0
93.7
93.4
Useful efficiency at 30%
%
90.2
90.6
91.0
Casing heat loss with burner on at nominal heat input
%
1.05
0.76
1.37
Casing heat loss with burner off
%
0.26
0.20
0.20
Chimney heat loss with burner on at nominal heat input
%
5.97
5.54
5.23
Energy efficiency marking (92/42/EC)
-
★★★
★★★
★★★
CH maximum working pressure
bar
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
35-78
35-78
35-78
l
7
7
7
No. nozzles
Expansion vessel capacity Consumption at nominal heat output (CH)
Methane
m3/h
2.70
3.23
3.49
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
2.37
2.56
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
2.41
2.60
Air-flue ΔT at nominal heat input
°C
95.0
101.0
105.0
Flue gas flow at nominal heat input
g/s
15.44
17.29
17.80
CO2 at nominal heat input
Methane
%
6.1
7.0
7.4
CO2 at nominal heat input
Propane
%
6.7
7.7
8.4
CO2 at nominal heat input
Butane
%
7.0
8.0
8.7
Supply pressure
Methane
mbar
13-20
13-20
13-20
Supply pressure
Propane
mbar
37
37
37
Supply pressure
Butane
mbar
28-30
28-30
28-30
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
122
134
134
Electric protection rating
-
IPX5D
IPX5D
IPX5D
Gas fitting
-
G½
G½
G½
CH fittings
-
G¾
G¾
G¾
DHW fittings
-
G½
G½
G½
Coaxial air intake/flue gas duct diameter
100/60
100/60
100/60
Split air intake/flue gas duct diameter
80+80
80+80
80+80
Power supply voltage/frequency
LxHxD
mm
420x750x315
Net weight
kg
32.00
33.00
33.00
Gross weight
kg
35.50
36.50
37.00
105
ATMOSPHERIC BOILERS
HEAT ONLY Wall-hung boilerS
FORMENTERA CTFS FORMENTERA CTN mono-thermal
➲
Touch screen user interface
➲
Ready for connection to an external probe (optional)
➲
26-plate DHW heat exchanger
➲
Controls to manage three different types of solar thermal systems fitted as standard (solar probe is optional)
➲
Boiler hydraulic replacement kit Available heat outputs: CTFS
CTFS
CTFS
24
28
32
kW
kW
CTN
CTN
24
28
kW
Pre-set to run on Methane or LPG
WARM COMFORT
106
kW
kW
CALDAIE
• Mono-thermal heat exchanger • 26-plate stainless steel DHW heat exchanger • 3-speed pump with integrated air purging device • Integrated hydraulic assembly including: three-way valve, automatic by-pass, safety valve, pressure transducer, unloading tap, connection to the expansion vessel • Integrated safety and modulation electronic board • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Virtual room temperature control with weather compensation via external temperature probe (option) • Management of high-and low-temperature heating zones via electric board (option) • Energy efficiency marking (92/42/EC) CTFS:★★★
Model
Type of gas
Code
FORMENTERA CTFS 24
METHANE
CFNxx2CA24
sealed chamber
LPG
CFNxx3CA24
FORMENTERA CTFS 28
METHANE
CFNxx2CA28
sealed chamber
LPG
CFNxx3CA28
FORMENTERA CTFS 32
METHANE
CFNxx2CA32
sealed chamber
LPG
CFNxx3CA32
FORMENTERA CTN 24
METHANE
CFNxx2CC24
open chamber
LPG
CFNxx3CC24
FORMENTERA CTN 28
METHANE
CFNxx2CC28
LPG
CFNxx3CC28
open chamber
CTN: ★★
Heat output kW
Efficiency at nominal heat output
Gross weight (kg)
23.7
93.0 %
37.50
28.6
93.7 %
38.00
30.8
93.4 %
38.50
23.1
90.6 %
36.00
27.4
90.0 %
36.50
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit. 107
ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water, open COMBUSTION CHAMBER
formentera CTFS and CTN Article
750
121
185 154 131
Dimensions and connection centre distances
Description
Code
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers for TFS models
0KITCOPE03
ProtProtection kit for outdoor installation, for condensing boilers for TFS models
0KITCOPE04
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Solar connection kit (for combi boilers)
0KITSOLC07
Connection kit for complex solar systems
0KITSOLC08
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
Immergas/ Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Formentera replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
Tahiti/ Formentera replacement kit
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
76 60 62 67 82 73 147
M CH flow (¾”)
132
210 135
G Gas inlet (½”)
47
C DHW outlet (½”)
420
121
185 154 131
76 60 62 67 82 73
G
C
F
210 135 132
147
R
210
750
bottom 147 view 135
92 76 60 62 67 82
73
132 47
G G
C
top view
F
210
210
92
M
CTN
121
185 154 131
76 60 62 315 67 82 73
R
117
420
121
185 154 131
47
M
R CH return (¾”)
315
CTFS
92
F Cold water inlet (½”)
121
185 154 131
315 420
315 73
76 60 62 67 82 210
117
210
ACCESSORIES 315
Article
WARM COMFORT
Description
Code
Air-intake/flue gas coaxial connection for type B22 installation
0ATTCOVE03
Electric zone kit with external probe
0KITZONE05
Pipes and taps cover
0COPETUB03
Standard split pipe kit for TFS models
0SDOPPIA11
Remote control
0CREMOTO04
“Plus” split pipe kit (0.5 meter long pipes) for TFS models
0SDOPPIA12
Fixing template (metal)
0DIMMECO11
External probe
0SONDAES01
Wall spacer kit
0DISTANZ00
Temperature probe for solar heating plants
PSPTMILL00
Ø 100/60 mm, 1 metre type “A” coaxial kit for TFS models
0KITCONC00
108
CTFS 24
CTFS 28
CTFS 32
CTN 24
CTN 28
-
11.0
13.0
15.0
11.0
13.0
kW
25.5
30.5
33.0
25.5
30.5
TECHNICAL SPECIFICATIONS No. nozzles Nominal heat input Reduced heat input
kW
12.5
13.5
16.0
10.0
12.5
Nominal heat output
kW
23.7
28.6
30.8
23.1
27.4
Reduced heat output
kW
11.1
12.0
14.3
8.5
10.8
Useful efficiency at nominal heat input
%
93.0
93.7
93.4
90.6
90.0
Useful efficiency at 30%
%
90.2
90.6
91.0
89.4
87.9
Casing heat loss with burner on at nominal heat input
%
1.05
0.76
1.37
1.88
2.83
Casing heat loss with burner off
%
0.26
0.20
0.20
0.57
0.57
Chimney heat loss with burner on at nominal heat input
%
5.97
5.54
5.23
7.52
7.17
Energy efficiency marking (92/42/EC)
-
★★★
★★★
★★★
★★
★★
CH maximum working pressure
bar
3.0
3.0
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
83
83
CH temperature range
°C
35-78
35-78
35-78
35-78
35-78
l
7
7
7
7
7
m /h
2.70
3.23
3.49
2.70
3.23
Expansion vessel capacity Consumption at nominal heat output (CH)
Methane
3
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
2.37
2.56
1.98
2.37
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
2.41
2.60
2.01
2.41
DHW maximum pressure
bar
6.0
6.0
6.0
6.0
6.0
DHW minimum pressure
bar
0.5
0.5
0.5
0.5
0.5
DHW nominal flow ∆T 30°C
l/min
11.6
14.2
15.1
11.2
13.5
DHW minimum heat input
l/min
3.0
3.0
3.0
3.0
3.0
DHW maximum working temperature
°C
62
62
62
62
62
DHW temperature range
°C
35-57
35-57
35-57
35-57
35-57
Air-flue ΔT at nominal heat input
°C
95.0
101.0
105.0
86.0
96.0
Flue gas flow at nominal heat input
g/s
15.44
17.29
17.80
20.73
21.70
CO2 at nominal heat input
Methane
%
6.1
7.0
7.4
4.9
5.5
CO2 at nominal heat input
Propane
%
6.7
7.7
8.4
5.6
6.5
CO2 at nominal heat input
Butane
%
7.0
8.0
8.7
5.8
6.5
Supply pressure
Methane
mbar
20
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
37
Supply pressure
Butane
mbar
28-30
28-30
28-30
28-30
28-30
V/Hz
230/50
230/50
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
3.15
3.15
Power absorption
W
125
134
134
86
86
Power supply voltage/frequency
Electric protection rating
-
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
Gas fitting
-
G½
G½
G½
G½
G½
CH fittings
-
G¾
G¾
G¾
G¾
G¾
DHW fittings
-
G½
G½
G½
G½
G½
mm
100/60
100/60
100/60
-
-
Coaxial air intake/flue gas duct diameter Split air intake/flue gas duct diameter
mm
80+80
80+80
80+80
-
-
Flue gas duct diameter
mm
-
-
-
130
130
LxHxD
mm
420x750x315
Net weight
kg
34.00
34.50
35.00
32.50
33.00
Gross weight
kg
37.50
38.00
38.50
36.00
36.50
109
ATMOSPHERIC BOILERS
WALL-HUNG COMBI BOILERS
FORMENTERA RTFS - RTN mono-thermal
➲
Touch screen user interface
➲
Ready for connection to an external probe (optional)
➲
26-plate DHW heat exchanger
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Boiler hydraulic replacement kit
Available heat outputs: RTFS
RTFS
RTFS
24
28
32
kW
kW
RTN
RTN
24
28
kW
Pre-set to run on Methane or LPG
WARM COMFORT
110
kW
kW
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas boiler, heating only, seaLED COMBUSTION CHAMBER
• Mono-thermal heat exchanger • 26-plate stainless steel DHW heat exchanger • 3-speed pump with integrated air purging device • Integrated hydraulic assembly including: automatic by-pass, safety valve, pressure transducer, unloading tap, connection to the expansion vessel • Integrated safety and modulation electronic board • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Virtual room temperature control with weather compensation via external temperature probe (option) • Management of high- and low-temperature heating zones via electric board (option) • Energy efficiency marking (92/42/EC) RTFS: ★★★ RTN: ★★
Model
Type of gas
Code
FORMENTERA RTFS 24
METHANE
CFNxx2RA24
sealed chamber
LPG
CFNxx3RA24
FORMENTERA RTFS 28
METHANE
CFNxx2RA28
sealed chamber
LPG
CFNxx3RA28
FORMENTERA RTFS 32
METHANE
CFNxx2RA32
sealed chamber
LPG
CFNxx3RA32
FORMENTERA RTN 24
METHANE
CFNxx2RC24
open chamber
LPG
CFNxx3RC24
FORMENTERA RTN 28
METHANE
CFNxx2RC28
LPG
CFNxx3RC28
open chamber
Heat output kW
Efficiency at nominal heat output
Gross weight (KG.)
23.7
93 %
35.50
28.6
93,7 %
36.50
30.8
93.4 %
37.00
23.1
90.6 %
34.50
27.4
90.0 %
35.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit. 111
formentera RTFS and RTN Dimensions and connection centre distances
750
121
185 154 131
Article
Code
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE04
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Gas and water tap kit
0KITRUBI04
Connection kit for complex solar systems
0KITSOLC08
Hot water storage temperature probe
0KITSOND00
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
IImmergas/ Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Formentera replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
185 154 131
92
47
132
76 60 62 67 82 73
G Gas inlet (½”) 210 147 135 M CH flow (¾”) F Cold water inlet (½”) R CH return (¾”) 420
RTFS
121
315
G
76 60 62 67 82 73 147
M
210 135
121
185 154 131
92
47
132
F R
185 154 131
315 76 60 62 67 82 73 210
bottom135 view 147
RTN
67view 82 73 76 60 62top
132
G
121
420
210
210
47
420
R
121
185 154 131
92
F
117
M
315
Description
315 76 60 62 67 82
ACCESSORIES Article 315
WARM COMFORT
210
Tahiti/ Formentera replacement kit
117
210
73
Description
Code
Air-intake/flue gas coaxial connection for type B22 installation
0ATTCOVE03
Pipes and taps cover
0COPETUB03
Remote control
0CREMOTO04
Fixing template (metal)
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Electric zone kit with external probe
0KITZONE05
Standard split pipe kit
0SDOPPIA11
0DIMMECO11
“Plus” split pipe kit (0.5 meter long pipes)
0SDOPPIA12
Wall spacer kit
0DISTANZ00
External probe
0SONDAES01
Ø 100/60 mm, 1 metre type “A” coaxial kit
0KITCONC00
Temperature probe for solar heating plants
PSPTMILL00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE03
112
TECHNICAL SPECIFICATIONS
RTFS 24
RTFS 28
RTFS 32
RTN 24
RTN 28
-
11.0
13.0
15.0
11.0
13.0
Nominal heat input
kW
25.5
30.5
33
25.5
30.5
Reduced heat input
kW
12.5
13.5
16
10.0
12.5
Nominal heat output
kW
23.7
28.6
30.8
23.1
27.4
Reduced heat output
kW
11.1
12.0
14.3
8.5
10.8
Useful efficiency at nominal heat input
%
93.0
93.7
93.4
90.6
90.0
Useful efficiency at 30%
%
90.2
90.6
91.0
89.4
87.9
Casing heat loss with burner on at nominal heat input
%
1.05
0.76
1.37
1.88
2.83
Casing heat loss with burner off
%
0.26
0.20
0.20
0.57
0.57
Chimney heat loss with burner on at nominal heat input
%
5.97
5.54
5.23
7.52
7.17
Energy efficiency marking (92/42/EC)
-
★★★
★★★
★★★
★★
★★
CH maximum working pressure
bar
3.0
3.0
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
83
83
CH temperature range
°C
35-78
35-78
35-78
35-78
35-78
No. nozzles
Expansion vessel capacity
l
7
7
7
7
7
3
Consumption at nominal heat output (CH)
Methane
m /h
2.70
3.23
3.49
2.70
3.23
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
2.37
2.56
1.98
2.37
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
2.41
2.60
2.01
2.41
Air-flue ΔT at nominal heat input
°C
95.0
101.0
105.0
86.0
96.0
Flue gas flow at nominal heat input
g/s
15.44
17.29
17.80
20.73
21.70
CO2 at nominal heat input
Methane
%
6.1
7.0
7.4
4.9
5.5
CO2 at nominal heat input
Propane
%
6.7
7.7
8.4
5.6
6.5
CO2 at nominal heat input
Butane
%
7.0
8.0
8.7
5.8
6.5
Supply pressure
Methane
mbar
20
20
20
20
20
Supply pressure
Propane
mbar
37
37
37
37
37
Supply pressure
Butane
mbar
28-30
28-30
28-30
28-30
28-30
V/Hz
230/50
230/50
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
3.15
3.15
Power absorption
W
125
134
134
86
86
Electric protection rating
-
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D
Gas fitting
-
G½
G½
G½
G½
G½
CH fittings
-
G¾
G¾
G¾
G¾
G¾
DHW fittings
-
G½
G½
G½
G½
G½
Flue gas duct diameter
mm
-
-
-
130
130
Coaxial air intake/flue gas duct diameter
mm
100/60
100/60
100/60
-
-
Split air intake/flue gas duct diameter
mm
80+80
80+80
80+80
-
-
LxHxD
mm
Power supply voltage/frequency
420x750x315
Net weight
kg
31.50
32.50
33.00
30.50
31.50
Gross weight
kg
35.50
36.50
37.00
34.50
35.00
113
ATMOSPHERIC BOILERS
HEAT ONLY WALL-HUNG combi BOILERs
FORMENTERA RBTFS mono-thermal
➲
Touch screen user interface
➲
Ready for connection to an external probe (optional)
➲
26-plate DHW heat exchanger
➲
Control of 2 heating zones via two temperature probes and 0KITZONE05 (optionals)
➲
Boiler hydraulic replacement kit
Available heat outputs:
24 kW
28 kW
Pre-set to run on Methane or LPG
WARM COMFORT
114
32 kW
CALDAIE
• Mono-thermal heat exchanger • 26-plate stainless steel DHW heat exchanger • 3-speed pump with integrated air purging device • Integrated hydraulic assembly including: automatic by-pass, safety valve, pressure transducer, unloading tap, connection to the expansion vessel • Integrated safety and modulation electronic board • Installation flexibility thanks to IPX5D electrical protection degree • Multifunctional relay for connection to systems with zone valves or to solar systems or to remote boiler shutdown alarms • Virtual room temperature control with weather compensation via external temperature probe (option) • Management of high- and low-temperature heating zones via electric board (option) • Energy efficiency marking (92/42/EC) RBTFS: ★★★
Model
Type of gas
Code
FORMENTERA RBTFS 24
METHANE
CFNxx2RF24
sealed chamber
LPG
CFNxx3RF24
FORMENTERA RBTFS 28
METHANE
CFNxx2RF28
sealed chamber
LPG
CFNxx3RF28
FORMENTERA RBTFS 32
METHANE
CFNxx2RF32
LPG
CFNxx3RF32
sealed chamber
Heat output kW
Efficiency at nominal heat output
Gross weight (KG.)
23.7
93 %
35.50
28.6
93.7 %
36.50
30.8
93.4 %
37.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit.
115
ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water, open COMBUSTION CHAMBER
formentera RBTFS Dimensions and connection centre distances
750
121
185 154 131
Article
Code
ProtProtection kit for outdoor installation, for condensing boilers
0KITCOPE04
Sludge remover
0KITDEFA00
Flow - return cold water 90° taps kit
0KITIDBA11
Gas and water tap kit
0KITRUBI04
Connection kit for complex solar systems
0KITSOLC08
Hot water storage temperature probe
0KITSOND00
Baxi/ Formentera replacement kit - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST08
Beretta/ Formentera replacement kit - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST09
IImmergas/ Formentera replacement kit - Victrix 50 - Victrix Mini
0KITSOST10
Vaillant/ Formentera replacement kit - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST11
Ariston/ Formentera replacement kit - Clas Premium - Genus Premium - Genus - Clas
0KITSOST12
185 154 131
92
47
132
76 60 62 67 82 73
G Gas inlet (½”) 210 147 135 M CH flow (¾”) F Cold water inlet (½”) R CH return (¾”) 420
RTFS
121
315
G
76 60 62 67 82 73 147
210 135
47 92
121
185 154 131
185 154 131
315 76 60 62 67 82 73 210
bottom135 view 147
RTN
67view 82 73 76 60 62top
132
G
121
420
132
F R
210
210
47
420
R
121
185 154 131
92
F
117
M
315
Description
315 76 60 62 67 82
ACCESSORIES Article 315
WARM COMFORT
210
Tahiti/ Formentera replacement kit
117
210
73
Description
Code
Air-intake/flue gas coaxial connection for type B22 installation
0ATTCOVE03
Pipes and taps cover
0COPETUB03
Remote control
0CREMOTO04
Fixing template (metal)
0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Electric zone kit with external probe
0KITZONE05
Standard split pipe kit
0SDOPPIA11
0DIMMECO11
“Plus” split pipe kit (0.5 meter long pipes)
0SDOPPIA12
Wall spacer kit
0DISTANZ00
External probe
0SONDAES01
Ø 100/60 mm, 1 metre type “A” coaxial kit
0KITCONC00
Temperature probe for solar heating plants
PSPTMILL00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers
0KITCOPE03
116
TECHNICAL SPECIFICATIONS
RBTFS 24
RBTFS 28
RBTFS 32
-
11.0
13.0
15.0
Nominal heat input
kW
25.5
30.5
33
Reduced heat input
kW
12.5
13.5
16
Nominal heat output
kW
23.7
28.6
30.8
Reduced heat output
kW
11.1
12.0
14.3
Useful efficiency at nominal heat input
%
93.0
93.7
93.4
Useful efficiency at 30%
%
90.2
90.6
91.0
Casing heat loss with burner on at nominal heat input
%
1.05
0.76
1.37
Casing heat loss with burner off
%
0.26
0.20
0.20
Chimney heat loss with burner on at nominal heat input
%
5.97
5.54
5.23
Energy efficiency marking (92/42/EC)
-
★★★
★★★
★★★
CH maximum working pressure
bar
3.0
3.0
3.0
CH maximum working temperature
°C
83
83
83
CH temperature range
°C
35-78
35-78
35-78
No. nozzles
Expansion vessel capacity
l
7
7
7
3
Consumption at nominal heat output (CH)
Methane
m /h
2.70
3.23
3.49
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
2.37
2.56
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
2.41
2.60
Air-flue ΔT at nominal heat input
°C
95.0
101.0
105.0
Flue gas flow at nominal heat input
g/s
15.44
17.29
17.80
CO2 at nominal heat input
Methane
%
6.1
7.0
7.4
CO2 at nominal heat input
Propane
%
6.7
7.7
8.4
CO2 at nominal heat input
Butane
%
7.0
8.0
8.7
Supply pressure
Methane
mbar
20
20
20
Supply pressure
Propane
mbar
37
37
37
Supply pressure
Butane
mbar
28-30
28-30
28-30
V/Hz
230/50
230/50
230/50
Fuse on the power supply
A
3.15
3.15
3.15
Power absorption
W
125
134
134
Electric protection rating
-
IPX5D
IPX5D
IPX5D
Gas fitting
-
G½
G½
G½
CH fittings
-
G¾
G¾
G¾
DHW fittings
-
G½
G½
G½
Flue gas duct diameter
mm
-
-
-
Coaxial air intake/flue gas duct diameter
mm
100/60
100/60
100/60
Split air intake/flue gas duct diameter
mm
80+80
80+80
80+80
LxHxD
mm
Power supply voltage/frequency
420x750x315
Net weight
kg
31.50
32.50
33.00
Gross weight
kg
35.50
36.50
37.00
117
ATMOSPHERIC BOILERS
HEAT ONLY WALL-HUNG combi BOILERs
ANTEA CTFS af ANTEA cTN af with bi-thermal heat exchanger
➲
Ultra-compact size
➲
LCD user interface
➲
7 litre expansion vessel
➲
Boiler change kit
Available with the following outputs:
24 kW
Pre-set to run on Methane or LPG
WARM COMFORT
118
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water
• Compact size LxHxD: 400 x 700 x 250 mm • Stainless steel 11-ramp burner • 5 pipes, bi-thermal, high efficiency, copper heat exchanger • Steel sheet and ceramic panel combustion chamber • Electronic board with continuous flame modulation based on three sensors (flow, return and DHW) and ionization flame control via a single electrode • LCD interface to view CH flow water temperature, DHW outlet temperature, failure codes, CH setting, DHW setting and operating status setting • Anti-fast, anti-freeze, pump anti-seizing, pump post-circulation and flue cleaning functions • Pump group including: water pressure switch, safety valve calibrated at 3 bar, system loading and unloading taps • Electrical protection class IPX4D
CTFS 24 AF
• Ready for connection to remote control • Energy efficiency marking 92/42/EC: CTN 24 AF ★★ CTFS 24 AF ★★★
Model ANTEA CTN 24 AF open chamber
ANTEA CTFS 24 AF sealed chamber
Type of gas
Code
METHANE
CAAxx2CC24
LPG
CAAxx3CC24
METHANE
CAAxx2CA24
LPG
CAAxx3CA24
THE PRICE INCLUDES: Paper template, dowels, blanking cap for air intake opening.
119
Power Power kW
Efficiency rating at Maximum output
Net weight (kg)
22.1
90.1 %
24.50
23.7
93.1 %
27.00
ANTEA CTFS af and ctn af Article
700
Dimensions and connection centre distances
400 250
CTFS 24 AF G
C
93
81 62
67
82
91
31
60
114
60
0KITIDBA11
Base hydraulic kit (copper pipes and straight cocks)
0KITIDBA13
Plus hydraulic kit (copper pipes, angle cocks and double cone fittings)
0KITIDBA14
Gas and water tap kit
0KITRUBI04
Kit for connection to solar plant with deviating valve and thermostatic mixing valve
0KITSOLC04
Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
Replacement kit Tahiti/Antea
0KITSOST07
0KITSOST14
63
bottom view
top view
CTN 24 AF F
G
C 118
Flow - return cold water 90° taps kit
R
66
232
Code
F
M
74
108
Description
R
66
60
62
67
82
91
81
114
31
M
63
bottom view
top view M CH flow (¾”) C Domestic hot water outlet (½”) G Gas inlet (½”)
F Cold water inlet (½”) R Domestic hot water return (¾”)
Description
Code
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
Covering for pipes and cocks
0COPETUB00
Basic kit for split vent ducts
0SDOPPIA11
Remote control
0CREMOTO04
Plus kit for split vent ducts (pipe length = 0.5 m)
0SDOPPIA12
Metal fixing template
0DIMMECO10
Wall spacer kit
0DISTANZ00
Sludge remover
0KITDEFA00
ACCESSORIES Article
WARM COMFORT
120
TECHNICAL SPECIFICATIONS
CTN 24 AF
CTFS 24 AF
-
11
11
Nominal heat input
kW
24.5
25.5
Reduced heat input
kW
12.0
12.5
Nominal heat output
kW
22.1
23.7
Reduced heat output
kW
10.5
11.0
Useful efficiency at nominal heat input
%
90.1
93.1
Useful efficiency at 30%
%
89.2
90.5
Casing heat loss with burner on at nominal heat input
%
3.92
1.01
Casing heat loss with burner off
%
0.60
0.23
Chimney heat loss with burner on at nominal heat input
%
5.98
5.89
Energy efficiency marking (92/42/EC)
-
★★
★★★
CH maximum working pressure
bar
3.0
3.0
CH maximum working temperature
°C
83
83
CH temperature range
°C
35-78
35-78
No. nozzles
Expansion vessel capacity
l
7
7
3
Consumption at nominal heat output (CH)
Methane
m /h
2.59
2.70
Consumption at nominal heat output (CH)
Propane
kg/h
1.90
1.98
Consumption at nominal heat output (CH)
Butane
kg/h
1.93
2.01
DHW maximum pressure
bar
6.0
6.0
DHW minimum pressure
bar
0.5
0.5
DHW nominal flow ∆T 30°C
l/min
10.3
11.1
DHW minimum heat input
l/min
3.0
3.0
DHW maximum working temperature
°C
62
62
DHW temperature range
°C
35-57
35-57
Air-flue ΔT at nominal heat input
°C
83.0
110.0
Flue gas flow at nominal heat input
g/s
16.72
14.18
CO2 at nominal heat input
Methane
%
5.7
7.2
CO2 at nominal heat input
Propane
%
7.3
6.8
CO2 at nominal heat input
Butane
%
6.7
8.6
Supply pressure
Methane
mbar
20
20
Supply pressure
Propane
mbar
37
37
Supply pressure
Butane
mbar
28-30
28-30
V/Hz
230/50
230/50
Fuse on the power supply
A
3.15
3.15
Power absorption
W
69
98
Power supply voltage/frequency
Electric protection rating
-
IPX4D
IPX4D
Gas fitting
-
G½
G½
CH fittings
-
G¾
G¾
DHW fittings
-
G½
G½
mm
-
100/60
Coaxial air intake/flue gas duct diameter Split air intake/flue gas duct diameter
mm
-
80+80
Flue gas duct diameter
mm
130
-
LxHxD
mm
400x700x250
Net weight
kg
22.50
25.00
Gross weight
kg
24.50
27.00
121
ATMOSPHERIC BOILERS
WALL-HUNG Combi boilers
ANTEA CTFS ANTEA cTN with mono-thermal heat exchanger
➲
Ultra-compact size
➲
LCD user interface
➲
7 litre expansion vessel
➲
Boiler change kit
➲
Ready for connection to an external probe (option)
➲
Additional relay for managing 2 heating zones (with same delivery temperature)
Available with the following outputs:
24 kW
Pre-set to run on Methane or LPG
WARM COMFORT
122
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water, OPEN OR SEALED COMBUSTION CHAMBER
• Mono-thermal, copper heat exchanger • Plate heat exchanger for production of domestic hot water • Exclusive circulation pump compact version with integrated air purging device • 7 litre expansion vessel • Sliding temperature operation with external probe (optional) • Factory-set for Methane or LPG • Compact size LxHxD: 400 x 700 x 250 mm • Steel sheet and ceramic panel combustion chamber • Electronic board with continuous flame modulation based on three probes (flow, return and DHW) and ionization flame control via a single electrode • LCD interface to view CH flow water temperature, DHW temperature, failure codes, CH setting, DHW setting and operating status setting
CTFS 24
• Anti-fast, anti-freeze, pump anti-seizing, pump post-circulation and flue cleaning functions. • Ready for connection to remote control • Energy efficiency marking 92/42/EC: CTFS 24 ★★★ CTN 24 ★★
Secondary plate heat exchanger
Mono-thermal heat exchanger
Model ANTEA CTFS 24 sealed chamber
ANTEA CTN 24 open chamber
Hydraulic assembly
Gas type
Code
METHANE
CAHxx2CA24
LPG
CAHxx3CA24
METHANE
CAHxx2CC24
LPG
CAHxx3CC24
Heat output kW
Efficiency rating at Maximum output
Gross weight (kg)
23.7
93.0 %
28.00
22.1
90.1 %
25.00
THE PRICE INCLUDES: Paper template, dowels, blanking cap for air intake opening.
123
ANTEA CTFS and CTN Article
Description
Code
Flow - return cold water 90° taps kit
0KITIDBA11
Base hydraulic kit (copper pipes and straight cocks)
0KITIDBA13
Plus hydraulic kit (copper pipes, angle cocks and double cone fittings)
0KITIDBA14
Gas and water tap kit
0KITRUBI04
Kit for connection to solar plant with deviating valve and thermostatic mixing valve
0KITSOLC04
Connection kit for complex solar systems
0KITSOLC08
Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
Replacement kit Tahiti/Antea
0KITSOST07
700
Dimensions and connection centre distances
250
400
CTFS
F
G
C
93
M 81 66
top view
60
62
82
63
bottom view
CTN
231,5
F
G
C M
R
66
M CH flow (¾”) C DHW outlet (½”) G Gas inlet (½”)
60
62
67
82
91
81
114
31
122
67
91
31
R 114
60
74
108
63
F Cold water inlet (½”) R CH return (¾”)
ACCESSORIES Article
WARM COMFORT
Description
Code
Covering for pipes and cocks
0COPETUB00
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Remote control
0CREMOTO04
Electrical kit for zone management with external probe
0KITZONE05
Metal fixing template
0DIMMECO10
Basic kit for split vent ducts
0SDOPPIA11
Wall spacer kit
0DISTANZ00
Plus kit for split vent ducts (pipe length = 0.5 m)
0SDOPPIA12
Sludge remover
0KITDEFA00
External probe
0SONDAES01
124
TECHNICAL SPECIFICATIONS
CTFS 24
CTN 24
-
11
11
Nominal heat input
kW
25.5
24.5
Reduced heat input
kW
12.5
12.0
Nominal heat output
kW
23.7
22.1
Reduced heat output
kW
11.1
10.5
Useful efficiency at nominal heat input
%
93.0
90.1
Useful efficiency at 30%
%
90.4
88.5
Casing heat loss with burner on at nominal heat input
%
1.01
3.92
Casing heat loss with burner off
%
0.23
0.60
Chimney heat loss with burner on at nominal heat input
%
5.89
5.98
Energy efficiency marking (92/42/EC)
-
★★★
★★
CH maximum working pressure
bar
3.0
3.0
CH maximum working temperature
°C
83
83
CH temperature range
°C
35-78
35-78
No. nozzles
Expansion vessel capacity
l
7
7
Consumption at nominal heat output (CH)
Methane
m3/h
2.70
2.59
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
1.90
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
1.93
DHW maximum pressure
bar
6.0
8.0
DHW minimum pressure
bar
0.5
0.5
DHW nominal flow ∆T 30°C
l/min
11.1
10.6
DHW minimum heat input
l/min
3.0
3.0
DHW maximum working temperature
°C
62
58
DHW temperature range
°C
35-57
35-50
Air-flue ΔT at nominal heat input
°C
98.0
83
Flue gas flow at nominal heat input
g/s
14.18
16.72
CO2 at nominal heat input
Methane
%
6.8
5.7
CO2 at nominal heat input
Propane
%
7.7
7.3
CO2 at nominal heat input
Butane
%
8.0
6.7
Supply pressure
Methane
mbar
20
20
Supply pressure
Propane
mbar
37
37
Supply pressure
Butane
mbar
28-30
28-30
V/Hz
230/50
230/50
Fuse on the power supply
A
3.15
3.15
Power absorption
W
98
73
Electric protection rating
-
IPX4D
IPX4D
Gas fitting
-
G½
G½
CH fittings
-
G¾
G¾
DHW fittings
-
Power supply voltage/frequency
G½
G½
Coaxial air intake/flue gas duct diameter
100/60
-
Split air intake/flue gas duct diameter
80+80
-
-
130
Flue gas duct diameter
mm
LxHxD
mm
400x700x250
Net weight
kg
26.00
23.00
Gross weight
kg
28.00
25.00
125
ATMOSPHERIC BOILERS
Wall-hung combi boilerS
ANTEA RTFS with mono-thermal heat exchanger
➲
Ultra-compact
➲
LCD user interface
➲
Expansion vessel 7 lt.
➲
Boiler hydraulic replacement kit
➲
Roady for connection to an external probe (optional)
➲
Additional relay managing 2 heating zones (with the same delivery temperature)
Available heat outputs:
24 kW
Pre-set to run on Methane or LPG
WARM COMFORT
126
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas with instant production of domestic hot water, OPEN OR SEALED COMBUSTION CHAMBER
• Mono-thermal, copper heat exchanger • Exclusively-designed, compact, water pump with integrated air purging device • Expansion vessel 7 lt. • Virtual room temperature control with weather compensation via external temperature probe (option) • Pre-set to run on Methane or LPG • Compact dimensions W x H x D: 400 x 700 x 250 mm • Combustion chamber made of sheet steel and ceramic panels • Integrated safety and modulation electronic board • LCD interface to view CH flow water temperature, DHW temperature, failure codes, CH setting, DHW setting and operating status setting • Anti-fast, antifreeze, pump anti-seizing, pump post-circulation, flue cleaning function • Remote Control connection pre-setting • Energy efficiency marking (92/42/EC): RTFS 24 ★★★
Model ANTEA RTFS 24 sealed chamber
Type of gas
Code
METHANE
CAHxx2RA24
LPG
CAHxx3RA24
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
23.7
93 %
26.50
THE PRICE INCLUDES: Paper template, dowels, blanking cap for air intake opening.
127
0
ANTEA RTFS Article
Dimensions and connection centre distances
Description 108
Code
93
0KITIDBA14
700
60
74
Plus hydraulic kit (copper pipes, angle cocks and double cone fittings)
M
250
400
top view G
81 60
62
67
82
62
67
82
91
63
F Cold water inlet (½”) R CH return (¾”)
91
31 114
66
60
63
ACCESSORIES Article
WARM COMFORT
R
81 62
91
31
60
0KITSOLC08
82 63 Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
67
bottom view
F
M CH flow (¾”) R G Gas inlet (½”)
M
81
114
60
31
R
66
0KITSOLC04
114
60
F
G
93
74
108
Kit for connection to solar plant with F valve and G deviating thermostatic mixing valve
Connection kit for complex solar systems
66
250
400
0KITRUBI04
M
93
74
108
Gas and water tap kit
Description
Code
Covering for pipes and cocks
0COPETUB00
Replacement kit Tahiti/Antea
0KITSOST07
Remote control
0CREMOTO04
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Metal fixing template
0DIMMECO10
Electrical kit for zone management with external probe
0KITZONE05
Wall spacer kit
0DISTANZ00
Basic kit for split vent ducts
0SDOPPIA11
Sludge remover
0KITDEFA00
Plus kit for split vent ducts (pipe length = 0.5 m)
0SDOPPIA12
Flow - return cold water 90° taps kit
0KITIDBA11
External probe
0SONDAES01
Base hydraulic kit (copper pipes and straight cocks)
0KITIDBA13
128
heat only Wall-hung boileRS
RTFS 24
No. nozzles
-
11
Nominal heat input
kW
25.5
Reduced heat input
kW
12.5
Nominal heat output
kW
23.7
Reduced heat output
kW
11.1
Useful efficiency at nominal heat input
%
93.0
Useful efficiency at 30%
%
90.4
Casing heat loss with burner on at nominal heat input
%
1.01
Casing heat loss with burner off
%
0.23
Chimney heat loss with burner on at nominal heat input
%
5.89
Energy efficiency marking (92/42/EC)
-
★★★
CH maximum working pressure
bar
3.0
CH maximum working temperature
°C
83
CH temperature range
°C
35-78
l
7
Expansion vessel capacity Consumption at nominal heat output (CH)
Methane
m3/h
2.70
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
Air-flue ΔT at nominal heat input
°C
98.0
Flue gas flow at nominal heat input
g/s
14.18
CO2 at nominal heat output
Methane
%
6.8
CO2 at nominal heat output
Propane
%
7.7
CO2 at nominal heat output
Butane
%
8.0
Supply pressure
Methane
mbar
20
Supply pressure
Propane
mbar
37
Supply pressure
Butane
mbar
28-30
V/Hz
230/50
Fuse on the power supply
A
3.15
Power absorption
W
98
Electric protection rating
-
IPX4D
Gas fitting
-
G½
CH fittings
-
G¾
DHW fittings
-
G½
Coaxial air intake/flue gas duct diameter
mm
100/60
Split air intake/flue gas duct diameter
mm
80+80
Flue gas duct diameter
mm
-
LxHxD
mm
400x700x250
Net weight
kg
25.40
Gross weight
kg
27.50
Power supply voltage/frequency
129
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
ANTEA RBTFS mono-thermal
➲
Ultra compact dimensions
➲
LCD user interface
➲
System management with solar collectors
➲
Electric kit (optional) for the management of more heating zones
➲
Room temperature can be set from the boiler if an external probe is installed
➲
Additional relay managing 2 heating zones
Available heat outputs:
40 kW
Pre-set to run on Methane or LPG
WARM COMFORT
130
CALDAIE ATMOSPHERIC BOILERS
Antea mono-thermal RTFS is a wall-hung gas boiler for heating only, with sealed chamber.
• Mono-thermal, copper heat exchanger • Reduced dimensions LxHxD: 400 x 700 x 250 mm • Steel sheet and ceramic panels combustion chamber • LCD interface to view CH flow water temperature, DHW temperature, failure codes, CH setting, DHW setting and operating status setting • Anti-fast, anti-freeze, pump anti-seizing, pump post-circulation and flue cleaning functions • Can be connected to a remote control • Can be connected to an outdoor probe (optional) for sliding temperature function • Remote Control connection pre-setting • Efficiency rating according to 92/42/EEC:★★★
Model
ANTEA RBTFS 40
Type of gas
Code
METHANE
CAHXX2RF40
LPG
CAHXX3RF40
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
41,0
92,7 %
24.50
THE PRICE INCLUDES: Paper template, dowels, blanking cap for air intake opening.
131
0
ANTEA RbTFS Article
Dimensions and connection centre distances
Description 108
Code
93
0KITIDBA14
700
60
74
Plus hydraulic kit (copper pipes, angle cocks and double cone fittings)
M
250
400
top view G
81 60
62
67
82
62
67
82
91
63
F Cold water inlet (½”) R CH return (¾”)
91
31 114
66
60
63
ACCESSORIES Article
WARM COMFORT
R
81 62
91
31
60
0KITSOLC08
82 63 Replacement kit Panarea/Antea
0KITSOST01
Replacement kit Baxi/Antea - Luna 3 System HT - Luna 3 Comfort HT - Luna Platinum HT - Prime HT
0KITSOST02
Replacement kit Beretta/Antea - Esclusive Green - Mynute Green - Mybute Sinthesi
0KITSOST03
Replacement kit Immergas/Antea - Victrix 50 - Victrix Mini
0KITSOST04
Replacement kit Vaillant/Antea - Eco Block Exclusive - Eco block Plus - Eco Block Pro
0KITSOST05
Replacement kit Ariston/Antea - Clas Premium - Genus Premium - Genus - Clas
0KITSOST06
67
bottom view
F
M CH flow (¾”) R G Gas inlet (½”)
M
81
114
60
31
R
66
0KITSOLC04
114
60
F
G
93
74
108
Kit for connection to solar plant with F valve and G deviating thermostatic mixing valve
Connection kit for complex solar systems
66
250
400
0KITRUBI04
M
93
74
108
Gas and water tap kit
Description
Code
Covering for pipes and cocks
0COPETUB00
Replacement kit Tahiti/Antea
0KITSOST07
Remote control
0CREMOTO04
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera / Aludens, Evodens, Futura, Superevo due
0KITSOST14
Metal fixing template
0DIMMECO10
Electrical kit for zone management with external probe
0KITZONE05
Wall spacer kit
0DISTANZ00
Basic kit for split vent ducts
0SDOPPIA11
Sludge remover
0KITDEFA00
Plus kit for split vent ducts (pipe length = 0.5 m)
0SDOPPIA12
Flow - return cold water 90° taps kit
0KITIDBA11
External probe
0SONDAES01
Base hydraulic kit (copper pipes and straight cocks)
0KITIDBA13
132
heat only Wall-hung boileRS
RBTFS 24
No. nozzles
-
11
Nominal heat input
kW
25.5
Reduced heat input
kW
12.5
Nominal heat output
kW
23.7
Reduced heat output
kW
11.1
Useful efficiency at nominal heat input
%
93.0
Useful efficiency at 30%
%
90.4
Casing heat loss with burner on at nominal heat input
%
1.01
Casing heat loss with burner off
%
0.23
Chimney heat loss with burner on at nominal heat input
%
5.89
Energy efficiency marking (92/42/EC)
-
★★★
CH maximum working pressure
bar
3.0
CH maximum working temperature
°C
83
CH temperature range
°C
35-78
Consumption at nominal heat output (CH)
Methane
m3/h
2.70
Consumption at nominal heat output (CH)
Propane
kg/h
1.98
Consumption at nominal heat output (CH)
Butane
kg/h
2.01
Air-flue ΔT at nominal heat input
°C
98.0
Flue gas flow at nominal heat input
g/s
14.18
CO2 at nominal heat output
Methane
%
6.8
CO2 at nominal heat output
Propane
%
7.7
CO2 at nominal heat output
Butane
%
8.0
Supply pressure
Methane
mbar
20
Supply pressure
Propane
mbar
37
Supply pressure
Butane
mbar
28-30
V/Hz
230/50
Fuse on the power supply
A
3.15
Power absorption
W
98
Electric protection rating
-
IPX4D
Gas fitting
-
G½
CH fittings
-
G¾
DHW fittings
-
G½
Coaxial air intake/flue gas duct diameter
mm
100/60
Split air intake/flue gas duct diameter
mm
80+80
Flue gas duct diameter
mm
-
LxHxD
mm
400x700x250
Net weight
kg
25.40
Gross weight
kg
27.50
Power supply voltage/frequency
133
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
PANAREA COMPACT CTFS af PANAREA COMPACT cTN af with bi-thermal heat exchange
➲
High efficiency rating ★★★ for CTFS model (according to dir. 92/42/CEE)
➲
Easy installation
➲
Easy for uncomplicated, intuitive operation
➲
Complete with comprehensive functionality
Available heat outputs:
24 kW
Pre-set to run on Methane or LPG
WARM COMFORT
134
CALDAIE ATMOSPHERIC BOILERS
Wall-hung gas combi boiler with instant production of domestic hot water
• Available in two versions: open chamber and natural draught (CTN) or sealed chamber and forced draught (CTFS) • Pre-set to run on Methane or LPG • CH and DHW supply • Compact dimensions L x H x D : 400 x 700 x 250 mm • 5-pipe, copper, bi-thermal, high efficiency heat exchanger • Integrated safety board with burner electronic ignition and flame sensing via single electrode • Multi-color Led technology function diagnostics • Anti-fast, anti-frost, pump anti-blocking, pump post-circulation functions • Pump assembly includes water pressure switch, 3 bar safety valve, drain cock
CTFS AF
Bi-thermal heat exchanger
• Energy efficiency marking (92/42/EC): CTN ★★ CTFS ★★★
Hydraulic assembly
Model PANAREA COMPACT CTFS 24 AF sealed chamber
PANAREA COMPACT CTN 24 AF open chamber
Type of gas
Code
METHANE
CPLxx2CA24
LPG
CPLxx3CA24
METHANE
CPLxx2CC24
LPG
CPLxx3CC24
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
23.7
93 %
27.50
22.2
90.6 %
26.00
THE PRICE INCLUDES: Paper template, dowels, blanking cap for air intake opening.
135
Panarea Compact CTFS and CTN Dimensions and connection centre distances CTN 24 AF
top view
CTFS 24 AF
bottom view
top view M CH flow (¾”) C DHW outlet(½”) G Gas inlet ½”)
Installation dimensions when installing kits 0KITDBA07 / 0KITDBA09.
bottom view F Cold water inlet(½”) R CH return (¾”)
ACCESSORIES Article
WARM COMFORT
Description
Code
Pipe and tap cover for COMPACT boilers
Article
Description
Code
0COPETUB00
Flow - return cold water 90° taps kit
0KITIDBA11
Metal template for COMPACT boilers
0DIMMECO04
Gas and water tap kit
0KITRUBI01
Ø 100/60 mm, 1 metre type “A” coaxial kit (TFS boilers)
0KITCONC00
Connection kit to solar system (for COMPACT boilers, indoor installation)
0KITSOLC00
“Plus” hydraulic kit for COMPACT boilers (copper pipes, right-angled taps and bicones)
0KITIDBA07
Standard kit with split pipes for COMPACT boilers
0SDOPPIA07
Standard hydraulic kit for COMPACT boilers (copper pipes and straight taps)
0KITIDBA09
“Plus” kit with split pipes for COMPACT boilers (pipe length 0.5 m)
0SDOPPIA08
136
TECHNICAL SPECIFICATIONS
CTN 24 AF
CTFS 24 AF
-
11
11
Nominal heat input
kW
24.5
25.5
CH reduced heat output
kW
12.0
12.5
Nominal heat output
kW
22.2
23.7
CH reduced heat output
kW
10.8
11.2
Useful efficiency at nominal heat input
%
90.6
93.0
Efficiency at 30 %
%
90.0
90.2
Casing heat loss with burner on at nominal heat input
%
3.20
1.20
Casing heat loss with burner off
%
0.60
0.20
Chimney heat loss with burner on at nominal heat input
%
6.10
5.80
Energy efficiency marking (92/42/EC
-
★★
★★★
CH maximum working pressure
bar
3.0
3.0
CH maximum working temperature
°C
83
83
CH temperature range
°C
35-78
35-78
l
6
6
No. nozzles
Expansion vessel capacity Consumption at nominal heat output:
Methane
m3/h
2.59
2.70
Consumption at nominal heat output:
Propane
kg/h
1.90
1.98
Consumption at nominal heat output:
Butane
kg/h
1.93
2.01
DHW maximum pressure
bar
8.0
8.0
DHW minimum pressure
bar
0.5
0.5
DHW production at ΔT 30 °C (EN 625)
l/min
10.6
11.4
DHW minimum flow
l/min
3.0
3.0
DHW maximum working temperature
°C
50
50
DHW temperature range
°C
35-50
35-50
Air-flue ΔT at nominal heat input
°C
85.0
107.0
Flue gas flow at nominal heat input
g/s
16.70
16.00
CO2 at nominal heat output
Methane
%
5.7
6.3
CO2 at nominal heat output
Propane
%
7.3
7.0
CO2 at nominal heat output
Butane
%
7.4
7.2
Maximum burner pressure
Methane
mbar
20
20
Maximum burner pressure
Propane
mbar
37
37
Maximum burner pressure
Butane
mbar
28-30
28-30
V/Hz
230/50
230/50
Fuse on the power supply
A
2
2
Power supply voltage/frequency
Power absorption totale
W
80
140
Electric protection rating
-
IPX4D
IPX4D
Gas fitting
-
G½
G½
CH fittings
-
G¾
G¾
-
G½
G½
Coaxial air intake/flue gas duct diameter
DHW fittings
mm
-
100/60
Split air intake/flue gas duct diameter
mm
-
80+80
Flue gas duct diameter
mm
130
-
LxHxP
mm
400x700x250
Net weight
kg
24.00
25.50
Gross weight
kg
26.00
27.50
137
ATMOSPHERIC BOILERS
WALL-HUNG combi BOILERS
Nias Dual btfs
➲
Large DHW withdrawals thanks to “Aqua Premium System”
➲
LCD user interface
Available heat outputs: IN-BUILT WATER STORAGE CAN BE disabled!
24 kW
28 kW
Pre-set to run on Methane or LPG
WARM COMFORT
138
32 kW
CALDAIE
• With a width of just 450 mm this boiler is the ideal replacement for traditional instantaneous boilers that are no longer capable of satisfying the growing demands for DHW • “AQUA PREMIUM SYSTEM” DHW production is based on a secondary plate heat exchanger + a 25 l stratification hot water storage which can be left inoperative when not needed • DHW expansion vessel as standard equipment • Can be connected to a remote control • Can be connected to an external probe (optional) for sliding temperature function • Possibility of zone management, high and low temperature (optional) Stratification water storage
Model
Code METHANE
CNJxx2BK24
sealed chamber
LPG
CNJxx3BK24
NIAS DUAL LINE TECH BTFS 28
NIAS DUAL LINE TECH BTFS 24
METHANE
CNJxx2BK28
sealed chamber
LPG
CNJxx3BK28
NIAS DUAL LINE TECH BTFS 32
METHANE
CNJxx2BK32
LPG
CNJxx3BK32
sealed chamber
Heat output kW
Efficiency at nominal heat output
Gross weight (kg.)
9.5 ÷ 23.8
93.20 %
75.50
10 ÷ 28.4
93.10 %
77.50
12.2 ÷ 31.3
93.10 %
79.00
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit.
139
ATMOSPHERIC BOILERS
Wall-hung gas boiler fitted with “Aqua Premium System”, secondary plate heat exchanger, built-in stratification water heater, SEALED COMBUSTION CHAMBER
4
nias dual BTFS ACCESSORIES Description
Code
C
96
71
F
R
0COPETUB02
43 56
98
75
98
80
Remote Control
0CREMOTO05
Fixing template (metal)
0DIMMECO03
Cock fitted with filter and check valve
0KITFILT02
Flow - return cold water 90° taps kit
0KITIDBA11
Kit of spare flexibles in coated stainless steel, No. 2 x ¾” – No. 3 x ½” L: 260/520 mm
0KITIDTR00
Gas and water tap kit
0KITRUBI01
Electric zone kit complete with external probe
0KITZONE00
Standard kit with split pipes complete with air-intake terminal
0SDOPPIA06
External probe
0SONDAES01
534
M
C
F
R
96
71
top view
M CH flow (¾”) C DHW outlet(½”) G Gas inlet ½”)
350 43 56
98
75
98
389
G
70
306
450
WARM COMFORT
M
Pipes and taps cover
120
120
0COPERIG01 G
70
750
306
Boiler cover
80
bottom view
F Cold water inlet(½”) R CH return (¾”)
140
389
Article
350
Dimensions and connection centre distances
Wall-hung boilerS with an integrated hot water storage
BTFS 24
BTFS 28
BTFS 32
Nominal heat input
kW
25.5
30.5
33.6
Reduced heat output
kW
10.6
11.0
13.5
Nominal heat output
kW
23.8
28.4
31.3
Reduced heat output
kW
9.5
10.0
12.2
Useful efficiency at max heat output
%
93.20
93.10
93.10
Efficiency at reduced load (30% Pn)
%
90.20
90.40
90.30
Useful efficiency at min heat output
%
Energy efficiency marking (92/42/EC)
90.1
90.90
90.00
★★★
★★★
★★★
Casing heat loss (boiler installed outdoors)
%
0.23
0.23
0.23
Chimney heat loss with burner on
%
6.57
6.67
6.67
Chimney heat loss with burner off
%
0.1
0.1
0.1
ΔT flue gas / air at nominal output
°C
75
75
92
g/sec
14
18.2
18.9
Flue mass flow (G20 Methane) CO2 content (Methane)
%
7.2
6.6
6.9
Consumption at nominal heat output
Methane
m3/h
2.7
3.23
3.46
Consumption at nominal heat output
Butane
Kg/h
2.01
2.4
2.62
Consumption at nominal heat output
Propane
Kg/h
1.98
2.37
2.51
Supply pressure
Methane
mbar
20
20
20
Supply pressure
Butane
mbar
29
29
29
Supply pressure
Propane
mbar
37
37
37
Nozzle diameter
Methane
mm
1.25
1.35
1.4
Nozzle diameter
Butane
mm
0.77
0.8
0.78
Nozzle diameter
Propane
mm
0.77
0.8
0.78
Burner pressure min-max
Methane
mbar
2.5-13.5
1.3-11.5
1.7-9.2
Burner pressure min-max
Butane
mbar
4.2-27.0
3.5-28.5
4.1-28.2
Burner pressure min-max
Propane
mbar
5.5-35.7
4.5-33.0
5.5-34.8
Water storage capacity
Methane
l
25
25
25
DHW supply at ΔT 30°C EN 625
Butane
l/10’
160
180
200
Energy efficiency marking prEN 13203
Propane
★★★
★★★
★★★
l/min
2
2
3.8
CH minimum pressure
bar
0.3
0.3
0.3
DHW minimum water flow CH maximum pressure
bar
8
8
8
DHW maximum temperature
°C
57
57
57
DHW minimum temperature
35
°C
35
35
DHW expansion vessel capacity
l
2
2
2
CH expansion vessel capacity
l
8
10
10
CH minimum flow rate
l/h
900
1000
1200
CH maximum pressure
bar
0.5
0.5
0.5
CH minimum pressure
bar
3
3
3
CH maximum temperature
°C
83
83
83
CH minimum temperature
°C
35
35
35
l
160
200
200
Maximum recommended system capacity CH flow/return diameter
inches
¾”
¾”
¾”
DHW inlet/outlet diameter
inches
½”
½”
½”
Gas connection diameter
inches
½”
½”
½”
mm
100/60
100/60
100/60
Split air intake/flue gas duct diameter
mm
80 + 80
80 + 80
80 + 80
Power supply voltage/frequency
V/Hz
230/50
230/50
230/50
Power absorption totale
W
180
200
230
Fuse on the power supply
A
2
2
2
IP
44
44
44
Coaxial air intake/flue gas duct diameter
Electric protection rating LxHxD
mm
450 x 750 x 534
Net weight
Kg
65.00
67.00
68.50
Gross weight
Kg
75.50
77.50
79.00
141
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
STANDARD BOILERS
ATMOSPHERIC BOILERS
FLOOR-STANDING BOILERS
143
Bali B
➲
Abundant DHW supply
➲
Stainless steel, 60 l, stratification hot water storage
➲
Versions available for management of a high- and low-temperature zones
➲
Easy maintenance operations
Available heat outputs: IN-BUILT WATER STORAGE CAN BE disabled!
32 kW
36 kW
Pre-set to run on Methane or LPG
WARM COMFORT
144
42 kW
CALDAIE ATMOSPHERIC BOILERS
cast-iron gas thermal group, dhw production via “aqua premium system” (plate heat exchanger and in-built dhw heater)
• Cast-iron heat exchanger with 3-pass technique • Electronic ignition, on/off pilot flame and ionization flame detection • Secondary plate exchanger • Stainless steel atmospheric burner • Stainless steel, 60 l, stratification hot water storage • Energy efficiency marking (92/42/EC) BTNE 32/42: ★★ BTFSE 32/36 ★★★ • V versions are equipped with two outlets: one for high temperature and one for low temperature areas • An optional kit allows to create a system with different zones on the base version
Model BALI BTNE 32 BALI BTNE 32 V BALI BTNE 42 BALI BTNE 42 V BALI BTFSE 32 BALI BTFSE 32 V BALI BTFSE 36 BALI BTFSE 36 V
Type of gas
Code
METHANE
CBSxx2BF32
LPG
CBSxx3BF32
METHANE
CBSxx2VV32
LPG
CBSxx3VV32
METHANE
CBSxx2BF42
LPG
CBSxx3BF42
METHANE
CBSxx2VV42
LPG
CBSxx3VV42
METHANE
CBSxx2BG32
LPG
CBSxx3BG32
METHANE
CBSxx2VZ32
LPG
CBSxx3VZ32
METHANE
CBSxx2BG36
LPG
CBSxx3BG36
METHANE
CBSxx2VZ36
LPG
CBSxx3VZ36
The boiler is also available in the following version: V: can manage 2 heating zones: one high-temperature and one low-temperature. 145
Heat output kW
Gross weight (kg)
31.4
194.50
31.4
208.50
42.5
210.50
42.5
224.50
32
239.00
32
253.00
36.5
239.00
36.5
253.00
bali b Dimensions and connection centre distances D
D
M
M
G
G
G
M
C
M
F
C
F
C
F
C
R1
R R
Model BTFSE
R
173
Model BTNE
M
R
M1
R1
C
F
G
D (mm)
BTNE 32 BTNE 32 V
G1
G1
G1
G1
G¾
G¾
G½
150
BTFSE 32 BTFSE 32 V
G1
G1
G1
G1
G¾
G¾
G½
--
CH flow (¾”) DHW outlet(½”) Gas inlet (½”) Cold water inlet(½”)
F
R1 R
173
Model BTFSE V
Model
M C G F
M1
M1
Model BTNE V
R CH return (¾”) M1 Low-temperature zone flow R1 Low-temperature zone return
ACCESSORIES Article
WARM COMFORT
Description
Code
Electrical kit for the management of 3 different heating zones through a remote control. Complete with external probe
Remote Control
Article
Description
Code
0CIRCSTA11
Standard kit with split pipes (TFS models)
0SDOPPIA05
0CREMOTO05
External probe
0SONDAES01
146
No. of primary heat exchanger elements
BTN E 32 BTN E 32 V 5
BTN E 42 BTN E 42 V 6
BTFS E 32 BTFS E 32 V 4
31.4
42.5
32.0
BTN E 36 BTN E 36 V 4 36.5
Heat output
kW
Heat input
kW
34.8
47.0
34.4
39.2
Efficiency at nominal load
%
90.22
90.51
93.10
93.10
Efficiency at reduced load (30%)
%
90.00
89.75
92.08
92.14
★★
★★
★★★
★★★
Chimney heat loss with burner on
%
9.28
8.99
5.00
5.40
Maintenance loss ΔT = 50°
%
0.5
0.5
1.9
1.5
4.5
6.0
8.3
8.2
EC efficiency class
CO2 content
G20
%
G30 Flue gas temperature
G20
°C
G30 Flue mass flow
G20 G30
Kg/h
No. nozzles Burner nozzle diameter
G20 G30
Pilot burner nozzle diameter
G20 G30
Gas pressure at the burner
G20 G30
Gas flow rate (15°C / 1013 mbar)
mm mm mbar
5.4
7.1
9.7
11.1
103
121
110/120
120/130
105
122
120/130
120/130
133.56
162
67
76
133.56
162
67
76
4
5
3
3
2.6
4.97
2.9
4.15
1.55
1.55
1.7
1.7
2 openings x 0.27 0.5
0.5
0.5
0.5
9.5
9.5
9.5
9.5
26.5
26.5
25.5
25.5 4.15
G20
Stm3/h
3.7
4.97
3.64
G30
Kg/h
2.76
3.7
2.7
3.1
19.8
23
16.4
16.4 20.4
Water content
l
Water content (V model)
23.8
27
20.4
CH minimum water flow
l/h
690
900
690
780
CH temperature range
°C
40-90
40-90
40-90
40-90
CH max pressure
bar
3
3
3
3
CH min pressure
bar
0.8
0.8
0.8
0.8
CH expansion vessel
l
12
18
12
12
Maximum recommended system capacity
l
240
240
240
240
DHW expansion vessel
l
5
5
5
5
DHW maximum temperature
°C
65
65
65
65
DHW maximum working pressure
bar
6
6
6
6 1
DHW minimum working pressure DHW minimum water flow
bar
1
1
1
l/min
3
3
3
3
l
60
60
60
60
Storage tank volume DHW production (ΔT=30°K according to EN 625)
l/10’
DHW efficiency rating according to prEN 13203
242
280
245
256
★★★
★★★
★★★
★★★
Ø CH fittings
inches
1”
1”
1”
1”
Ø DHW fittings
inches
¾”
¾”
¾”
¾”
Ø Gas fitting
inches
½”
½”
½”
½”
mm
150
150
-
-
TN version Flue gas duct diameter TFS version Air intake/flue gas duct diameter
mm
-
-
Electrical power supply
V-Hz
230/50
230/50
230/50
230/50
A
4
4
4
4
W
200
200
250
250
Fuse on the power supply Power absorption LxHxD
mm
100/60 80+80 100/60 80+80
600 x 1370 x 800
Net weight
Kg
180.50
196.50
225.50
225.50
Net weight V model
Kg
194.50
208.50
239.00
239.00
Gross weight
Kg
194.50
210.50
239.00
239.00
Gross weight V model
Kg
208.50
224.50
253.00
253.00
147
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
BALI Rtn / rtn E floor-standing gas cast-iron boiler, heating only, open combustion chamber, natural draught, complete with expansion vessel and circulation pump Model BALI RTN E 18 BALI RTN E 24 BALI RTN E 32 BALI RTN E 36 BALI RTN E 48 BALI RTN E 60 BALI RTN E 70 BALI RTN E 80 BALI RTN E 90 BALI RTN E 100
Model BALI RTN 18 BALI RTN 24 BALI RTN 32 BALI RTN 36 BALI RTN 48 BALI RTN 60 BALI RTN 70 BALI RTN 80 BALI RTN 90 BALI RTN 100
Type of gas
Code
METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG
CBAxx2MF18 CBAxx3MF18 CBAxx2MF24 CBAxx3MF24 CBAxx2MF32 CBAxx3MF32 CBAxx2MF36 CBAxx3MF36 CBAxx2MF48 CBAxx3MF48 CBAxx2MF60 CBAxx3MF60 CBAxx2MF70 CBAxx3MF70 CBAxx2MF80 CBAxx3MF80 CBAxx2MF90 CBAxx3MF90 CBAxx2MF1A CBAxx3MF1A
Type of gas
Code
METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG METHANE LPG
CBAxx2NC18 CBAxx3NC18 CBAxx2NC24 CBAxx3NC24 CBAxx2NC32 CBAxx3NC32 CBAxx2NC36 CBAxx3NC36 CBAxx2NC48 CBAxx3NC48 CBAxx2NC60 CBAxx3NC60 CBAxx2NC70 CBAxx3NC70 CBAxx2NC80 CBAxx3NC80 CBAxx2NC90 CBAxx3NC90 CBAxx2NC1A CBAxx3NC1A
Heat output kW
Gross weight Kg.
18.0 24.0
116.00
31.5
151.00
36.0
151.00
48.0
183.50
60.0
229.00
70.0
263.50
80.0
297.50
90.0
332.50
100.0
371.50
Heat output kW
Gross weight Kg.
24.0
116.00
31.5
151.00
36.0
151.00
48.0
183.50
60.0
229.00
70.0
263.50
80.0
297.50
90.0
332.50
100.0
371.50
Dimensions and connection centre distances BALI RTN E
• • • • • • • • •
•
Cast-iron floor-standing boiler for central heating only (R), open chamber, natural draught version and electronic ignition Pre-set to run on methane or LPG Stainless steel, multi-gas atmospheric burner Electronic ignition with on/off pilot flame (RTN E) Piezo electric ignition (RTN) Ionization flame detection (RTN E) Thermocouple flame detection (RTN) Safety limit thermostat Flue gas safety thermostat Control and management panel, CH pump control, designed to be connected to a room thermostat and a water pressure switch Pre-set for connection to an electrical board for management of a remote hot water storage and for connection to an electrical board for management of three different CH temperature zones (see accessories list ) Model
H
L
D
M
R
G
24
850
525
130
G1½
G1½
G¾
32
850
625
130
G1½
G1½
G¾
48
850
765
150
G1½
G1½
G¾
60
1005
905
180
G1½
G1½
G1
70
1005
1052
180
G1½
G1½
G1
80
1005
1153
200
G1½ G1½
G1
18 18 48) 48)
90
1005
1280
220
G1½ G1½
G1
60 60 100) 100)
100
1005
1430
250
G1½ G1½
G1
18 48) 60 100)
WARM COMFORT
BALI RTN / rtn E
18.0
148
TECHNICAL SPECIFICATIONS
RTN E 18
RTN E 24
RTN E 32
RTN E 36
RTN E 48
RTN E 60
RTN E 70
RTN E 80
RTN E 90
RTN E 100
Heat input
kW
20
26.6
34.4
36.9
52.8
66.0
76.3
87.3
98.2
109.7
Heat output
kW
18
24
31.5
36.0
48
60
70
80
90
100
PIEZO ELECTRIC (RTN) - ELECTRONIC (RTN E)
Efficiency at nominal heat input
%
89.6
90.9
90.9
90.83
91.84
91.7
91.7
91.7
91.6
91.6
Efficiency at reduced load (30%)
%
89.2
91.1
89.0
90.75
90.4
90.6
90.4
90.3
90.3
90.22
★★
★★
★★
★★
★★
★★
★★
★★
★★
★★
EC efficiency class Maintenance loss at ΔT =50°
%
2.3
2.2
2
2
2.3
1.8
1.7
1.6
1.5
1.2
Chimney heat loss with burner off
%
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Chimney heat loss with burner on
%
8.2
6.9
7.1
7.2
8.2
6.5
6.6
6.7
7.0
7.2
Maximum working pressure
bar
4
4
4
4
4
4
4
4
4
4
Water content
litres
10
10
13.4
13.4
16.8
20.2
23.5
26.8
30.1
33.4
Water minimum flow
l/h
400
520
680
770
1030
1200
1500
1700
1900
2100
Maximum water temperature
°C
85
85
85
85
85
85
85
85
85
85
Flue gas duct diameter
Ø
110
130
130
130
150
180
180
200
220
250
CH flow diameter
Ø
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
CH return diameter
Ø
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
1” ½
Gas connection diameter
Ø
¾”
¾”
¾”
1”
¾”
1”
1”
1”
1”
1”
Electrical power supply
V/Hz
Power absorption
230/150
W
10
10
10
10
10
20
20
20
20
20
Dimensions: Width
mm
450
450
450
450
450
450
450
450
450
450
Depth
mm
525
525
625
625
765
935
1052
1153
1280
1430
Height
mm
850
850
850
850
850
1000
1000
1000
1000
1000
Net weight
Kg
-
106.00
138.50
138.50
175.00
213.00
248.00
279.50
315.00
355.00
Gross weight
Kg
-
116.00
151.00
151.00
183.50
229.00
263.50
297.50
332.50
371.50
ACCESSORIES Article
Description
Code
Remote control for climate control unit (temperature adjustment)
Article
Description
Code
0CREMOTO00
Electric kit to manage 3 heating areas
0KITPOMZ00
Remote control for thermoregulation control unit (all functions)
0CREMOTO01
Hydraulic kit for the connection to a WHPF BO external horizontal hot water storage
0KITPOVA03
Daily timer kit
0KITBEST04
Pump and 12 litre expansion vessel kit, with manometre, water pressure switch, safety valve (suitable for models: 18, 24, 32)
0KITPOVA04
Weekly timer kit
0KITBEST05
Hydraulic kit for the connection to a WHPF BO horizontal hot water storage + pump and expansion vessel (suitable for models: 18, 24, 32)
0KITPOVA05
Electrical kit for the connection to an external hot water storage (optional)
0KITBEST06
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
Climate control unit kit
0KITCEEL02
149
ATMOSPHERIC BOILERS
Ignition type
BALI RTN PVE floor-standing gas cast-iron boiler, heating only, open combustion chamber, natural draught Model BALI RTN PVE 18 BALI RTN PVE 24 BALI RTN PVE 32 BALI RTN PVE 36
Type of gas
Code
METHANE
CBAxx2MH18
LPG
CBAxx3MH18
METHANE
CBAxx2MH24
LPG
CBAxx3MH24
METHANE
CBAxx2MH32
LPG
CBAxx3MH32
METHANE
CBAxx2MH36
LPG
CBAxx3MH36
Heat output kW
Gross weight Kg.
18.0
125.50
24.0
125.50
31.5
159.00
36.0
159.00
Model
L
D
M
R
G
18
525
110
G¾
G¾
G¾
24
525
130
G¾
G¾
G¾
32
625
130
G¾
G¾
G¾
36
625
130
G¾
G¾
G¾
Dimensions and connection centre distances BALI RTN - PVE
BALI RTN PV PVE
• • • • • • •
•
•
Cast-iron floor-standing boiler for central heating only (R), open chamber, natural draught version (TN), with pump and expansion vessel. Pre-set to run on methane or LPG Stainless steel, multi-gas atmospheric burner Circulation pump (P) 8-lt. expansion vessel (V version) Safety limit thermostat Flue gas safety thermostat Control and management panel, CH pump control, designed to be connected to a room thermostat and a water pressure switch Pre-set for connection to an electrical board for management of a remote hot water storage and for connection to an electrical board for management of three different CH temperature zones (see accessories list) Energy efficiency marking (92/42/EC) ★★ Model RTN PVE:
• Electronic ignition (E) with on/off pilot flame. • Ionization flame detection
M CH flow (¾”) G Gas inlet (½”) R CH return (¾”)
WARM COMFORT
150
TECHNICAL SPECIFICATIONS
RTN PVE 18
RTN PVE 24
RTN PVE 32
RTN PVE 36
34.4
39.2
31.5
36
Heat input
kW
20
26.6
Heat output
kW
18
24
Ignition type
-
Efficiency at nominal heat input
%
89.6
90.9
90.9
90.83
Efficiency at reduced load (30%)
%
89.2
91.1
89.0
90.75
EC efficiency class
-
★★
★★
★★
★★
Maintenance loss ΔT = 50°
%
2.3
2.2
2.0
2.0
Chimney heat loss with burner off
%
0.2
0.2
0.2
0.2
Chimney heat loss with burner on
%
8.2
6.9
7.1
7.2
Maximum working pressure
bar
3
3
3
3
Water content
litres
10
10
13.4
13.4
Water minimum flow
l/h
400
520
680
770
Maximum water temperature
°C
85
85
85
85
Flue gas duct diameter
Ø
110
130
130
130
CH flow diameter
Ø
¾”
¾”
¾”
¾”
CH return diameter
Ø
¾”
¾”
¾”
¾”
Gas connection diameter
Ø
¾”
¾”
¾”
¾”
Expansion vessel capacity
litres
8
8
10
10
Circulation pump available head
m.c.a.
6
6
6
6
110
110
Electrical power supply
V/Ph/Hz
Power absorption
230/1/50
W
Dimensions: Width
110
110
mm
450
450
450
450
Depth
mm
525
525
625
625
Height
mm
850
850
850
850
Net weight
Kg
119..00
119.00
138.50
138.50
Gross weight
Kg
125.50
125.50
159.00
159.00
ACCESSORIES Article
Description
Code
Remote control for climatic control unit (temperature regulation)
Article
Description
Code
0CREMOTO00
Thermoregulation control unit kit
0KITCEEL02
Remote control for climatic control unit (all functions)
0CREMOTO01
Electrical kit for the management of 3 different heating zones
0KITPOMZ00
Day timer kit
0KITBEST04
Hydraulic kit for the connection to a WHPF BO external horizontal hot water storage
0KITPOVA03
Weekly timer kit
0KITBEST05
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
Electrical kit for the connection to an external hot water storage (optional)
0KITBEST06
151
ATMOSPHERIC BOILERS
ELECTRONIC
BALI Rtn T FLOO-STANDING CAST-IRON BOILER, HEATING ONLY (R), OPEN COMBUSTION CHAMBER AND NATURAL DRAUGHT (TN). Model BALI RTN T 24 BALI RTN T 32 BALI RTN T 48
Type of gas
Code
METHANE
CBAxx2NB24
LPG
CBAxx3NB24
METHANE
CBAxx2NB32
LPG
CBAxx3NB32
METHANE
CBAxx2NB48
LPG
CBAxx3NB48
Heat output kW
Gross weight Kg
24.0
118.00
31.5
153.50
48.0
188.50
Model
L
D
M
R
G
24
525
130
G1½
G1½
G¾
32
625
130
G1½
G1½
G¾
48
725
150
G1½
G1½
G¾
Dimensions and connection centre distances BALI RTN T
BALI RTN T Cast-iron floor-standing boiler for central heating only, open chamber, natural draught version. It works without connection to power supply network. • Pre-set to run on methane or LPG • Stainless steel, multi-gas atmospheric burner • Safety limit thermostat • Flue gas safety thermostat • Control and management panel, designed to be connected to a room thermostat switch • Piezo electric pilot flame ignition • Main burner ignition with termopila • Flame deletection with thermocouple • Energy efficiency marking (92/42/EC) ★★
M CH flow (1 ½”) G Gas inlet (¾”) R CH return (1 ½”)
WARM COMFORT
152
TECHNICAL SPECIFICATIONS
RTN T 24
RTN T 32
RTN T 48
Heat input
kW
26.6
34.4
52.8
Heat output
kW
24
31.5
48
PIEZO ELECTRIC
Efficiency at nominal heat input
%
90.9
90.9
91.84
Efficiency at reduced load (30%)
%
91.1
89.0
90.4
★★
★★
★★
EC efficiency class Maintenance loss at ΔT =50°
%
2.2
2
2.3
Chimney heat loss with burner off
%
0.2
0.2
0.2
Chimney heat loss with burner on
%
6.9
7.1
8.2
Maximum working pressure
bar
4
4
4
Water content
litres
10
13.4
16.8
Water minimum flow
l/h
520
680
1030
Maximum water temperature
°C
85
85
85
Flue gas duct diameter
Ø
130
130
150
Split flue gas discharge diameter
Ø
-
-
-
CH flow diameter
Ø
1” ¼
1” ¼
1” ¼
CH return diameter
Ø
1” ¼
1” ¼
1” ¼
Gas connection diameter
Ø
¾”
¾”
¾”
V/Hz
230/1/50
230/1/50
230/1/50
W
10
10
10
Dimensions: Width
mm
450
450
450
Depth
mm
525
625
765
Height
mm
850
850
850
Net weight
Kg
107.00
142.00
177.00
Gross weight
Kg
118.00
153.50
188.50
Electrical power supply Power absorption
ACCESSORIES Article
Description
Code
Hydraulic kit for the connection to a WHPF BO external horizontal cylinder
0KITPOVA03
153
ATMOSPHERIC BOILERS
Ignition type
BALI RTFS E FLOO-STANDING CAST-IRON BOILER, HEATING ONLY (R), SEALED COMBUSTION CHAMBER AND FORCED DRAUGHT (TFS) Model
Code
BALI RTFS E 32 BALI RTFS E 36
METHANE
CBAxx2MG32
LPG
CBAxx3MG32
METHANE
CBAxx2MG36
LPG
CBAxx3MG36
Heat output kW
Gross weight Kg.
32.0
169.00
36.5
169.00
Model
L
M
R
G
32
610
G1
G1
G½
36
610
G1
G1
G½
Dimensions and connection centre distances BALI RTFS E
BALI RTFS E Cast-iron floor-standing boiler for central heating only, sealed chamber, forced draught version. • Pre-set to run on methane or LPG • Stainless steel, multi-gas atmospheric burner • Electronic ignition (E) with on/off pilot flame • Ionization flame detection • Safety limit thermostat • Safety flue gas thermostat • Control and management panel, CH pump control, designed to be connected to a room thermostat and a water pressure switch • Pre-set for connection to an electrical board for management of a remote hot water storage and for connection to an electrical board for management of three different CH temperature zones (see accessories list)
G Gas inlet M CH flow R CH return
WARM COMFORT
154
Heat input Heat output Ignition type Efficiency at nominal heat input Efficiency at reduced load (30%) EC efficiency class Maintenance loss at ΔT =50° Chimney heat loss with burner off Chimney heat loss with burner on Flue gas temperature (G 20) Flue gas temperature (G 30) Flue mass flow Maximum working pressure Water content Water minimum flow Maximum water temperature Gas pressure at the burner (G 20) Gas pressure at the burner (G 30) Coaxial flue gas discharge diameter Split flue gas discharge diameter CH flow diameter CH return diameter Gas connection diameter Electrical power supply Power absorption Dimensions: Width Depth Height Net weight Gross weight
kW kW % % % % % °C °C Kg/h bar litres l/h °C mbar mbar Ø Ø Ø Ø Ø V/Hz W mm mm mm Kg Kg
RTFS E 32
RTFS E 36
34.4 32
39.2 36.5
ELECTRONIC 93.1 93.1 92.08 92.14 ★★★ ★★★ 1.9 1.5 0.1 0.1 5.0 5.5 110/120 120/130 120/130 120/130 67 76 4 4 13.4 13.4 690 780 85 85 9.5 12 25.5 26 100/60 100/60 80 80 1” 1” 1” 1” ½” ½” 230/50 230/50 60 60 450 450 610 610 850 850 156.50 156.50 169.00 169.00
ACCESSORIES Article
Description
Code
Remote control for climate control unit (temperature adjustment)
Remote control for thermoregulation control unit (all functions)
per mod. TFS
Code
0CREMOTO00
Electric kit to manage 3 heating areas
0KITPOMZ00
0CREMOTO01
Hydraulic kit for the connection to a WHPF BO external horizontal hot water storage
0KITPOVA03
0KITBEST04
Pump and 12 litre expansion vessel kit, with manometre, water pressure switch, safety valve (suitable for models: 18, 24, 32)
0KITPOVA04
Weekly timer kit
0KITBEST05
Hydraulic kit for the connection to a WHPF BO horizontal hot water storage + pump and expansion vessel (suitable for models: 18, 24, 32)
0KITPOVA05
Electrical kit for the connection to an external hot water storage (optional)
0KITBEST06
Standard kit with split pipes (TFS models)
0SDOPPIA05
Climate control unit kit
0KITCEEL02
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
Daily timer kit
Article
155
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
Elba Dual FLOOR-STANDING CAST-IRON BOILER, HEATING ONLY (R), CAN OPERATE WITH BLOWN GAS or DIESEL OIL BURNERS Model
Code
Heat output KW
Gross weight (kg)
ELBA DUAL 23
CEBxxGNB23
24.0
132.50
ELBA DUAL 33
CEBxxGNB33
33.0
159.50
ELBA DUAL 43
CEBxxGNB43
43.0
191.00
ELBA DUAL 53
CEBxxGNB53
53.0
213.00
ELBA DUAL 63
CEBxxGNB63
63.0
239.00
ELBA DUAL 73
CEBxxGNB73
73.0
263.50
Model
L
M
R
23
400
G1¼
G1
33
525
G1¼
G1
43
625
G1¼
G1
53
700
G1¼
G1
63
800
G1¼
G1
73
900
G1¼
G1
Dimensions and connection centre distances ELBA DUAL
WARM COMFORT
156
TECHNICAL SPECIFICATIONS
23
33
43
Efficiency class CE
★★
★★
★★
63
73
★★
★★
★★
B23
Nominal heat input (Qn)
kW
26.6
36.3
47.2
57.9
68.5
79.3
Nominal heat output (50°-30°)
kW
24
33
43
53
63
73
Efficiency at nominal load
%
90
91
91
91.5
92
92
Efficiency at reduced load (30%)
%
89.7
90.7
90.7
91.1
91.6
91.6
3
4
5
6
7
8
°C
49-82
49-82
49-82
49-82
49-82
49-82
l
15.5
19.5
23.5
27.5
31.5
35.5
Minimum water flow rate
l/h
680
950
1230
1520
1800
2150
Combustion chamber length
mm
208
308
408
508
608
708
°C
210
190
188
202
181
175 114.5
No. of exchanger elements Temperature range Water content
Flue gas temperature Flue gas flow
Kg/h
40
53.2
69.3
83.1
97.7
Operating pressure
Bar
4
4
4
4
4
4
Flue gas pressure loss at maximum heat input
Pa
13
25
40
40
50
65
Water side pressure loss at 10° ∆T
Pa
4800
5600
6000
7100
10000
11200
Maintenance loss at ΔT =50°
%
0.3
0.3
0.3
0.3
0.3
0.3
Opening maximum Ø for burner head
mm
110
110
110
110
110
110
Flue gas vent Ø
mm
150
150
150
150
150
150
Input voltage
V
230
230
230
230
230
230
Frequency
Hz
50
50
50
50
50
50
Electric power mains supply fuse
A
4
4
4
4
4
4
Electric protection rating
-
IP40
IP40
IP40
IP40
IP40
IP40
Net weight
Kg
124.00
150.00
179.00
202.00
232.50
250.00
Gross weight
Kg
132.50
159.50
191.00
213.00
239.00
263.50
ACCESSORIES Article
Description
Code
Remote control for climate control unit (temperature adjustment)
Remote control for thermoregulation control unit (all functions)
Description
Code
0CREMOTO00
Electric kit to manage 3 heating areas
0KITPOMZ00
0CREMOTO01
Hydraulic kit for the connection to a WHPF BO external horizontal hot water storage
0KITPOVA03
0KITBEST04
Pump and 12 litre expansion vessel kit, with manometre, water pressure switch, safety valve (suitable for models: 18, 24, 32)
0KITPOVA04
Weekly timer kit
0KITBEST05
Hydraulic kit for the connection to a WHPF BO horizontal hot water storage + pump and expansion vessel (suitable for models: 18, 24, 32)
0KITPOVA05
Electrical kit for the connection to an external hot water storage (optional)
0KITBEST06
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
Climate control unit kit
0KITCEEL02
Daily timer kit
Article
157
ATMOSPHERIC BOILERS
Type of installation
53
Rodi Dual 70÷1300 kW
➲
Two-star efficiency
➲
Electric panel for multi-zone management
➲
Working pressure 6 bar
Available heat outputs:
FROM
WARM COMFORT
158
70 kW
TO
1300 kW
CALDAIE ATMOSPHERIC BOILERS
Pressurized, STEEL, high-efficiency boiler, FOR BLOWN GAS BURNERS
• Flue gas pipes boiler body in steel with flame inversion furnace
• Control and management electric panel (to be ordered separately) in the standard version (C) with two-stage burner control, heating circulation pump control, recirculation pump control, external hot water storage pre-setting, operating and alarm signals; moreover the multi-zone version (PC) is equipped with a control for three zone pumps
• Operation with blown diesel and gas burners • Holder for control thermometer • Energy efficiency marking (92/42/EC) ★★
KW power output
Overall dimensions
max
min
L (mm)
H (mm)
P (mm)
Weight (empty boiler, kg.)
CRPxxGNB70
70
35
750
1030
1055
226.00
RODI DUAL 80
CRPxxGNB80
80
40
750
1030
1055
226.00
RODI DUAL 90
CRPxxGNB90
90
45
750
1030
1195
268.00
RODI DUAL 100
CRPxxGNB1A
100
50
750
1030
1195
268.00
RODI DUAL 120
CRPxxGNB1C
120
60
750
1030
1195
268.00
RODI DUAL 150
CRPxxGNB1F
150
75
800
1080
1440
356.00
RODI DUAL 200
CRPxxGNB2A
200
100
800
1080
1440
356.00
RODI DUAL 250
CRPxxGNB2F
250
125
800
1180
1690
441.00
RODI DUAL 300
CRPxxGNB3A
300
150
900
1180
1690
485.00
RODI DUAL 350
CRPxxGNB3F
350
175
900
1180
1940
485.00
RODI DUAL 400
CRPxxGNB4A
400
200
940
1190
1872
594.00
RODI DUAL 500
CRPxxGNB5A
500
250
1160
1380
1950
863.00
RODI DUAL 620
CRPxxGNB6C
620
310
1160
1380
2240
973.00
RODI DUAL 750
CRPxxGNB7F
750
375
1290
1510
2255
1215.00
RODI DUAL 850
CRPxxGNB8F
850
425
1290
1510
2255
1215.00
RODI DUAL 950
CRPxxGNB9F
950
475
1290
1510
2500
1427.00
RODI DUAL 1020
CRPxxGNB1K
1020
510
1440
1660
2500
1853.00
RODI DUAL 1200
CRPxxGNB1M
1200
600
1440
1660
2500
1853.00
RODI DUAL 1300
CRPxxGNB1N
1300
650
1440
1660
2500
1853.00
Model
Code
RODI DUAL 70
159
RODI DUAL 70÷1300 kW Dimensions and connection centre distances
Ø c
Øb
241
N1 Boiler flow N2 Boiler return N3 Equipment connection N4 Boiler filling/draining connection
N5 Safety bi-thermal valve(s) N6 Bulb holders N8 Control holder
ACCESSORIES Article
WARM COMFORT
Description
Code
Remote control for climatic control unit (temperature regulation)
Remote control for climatic control unit (all functions)
Article
Description
Code
0CREMOTO00
Climatic control unit kit for two-stage burners
0KITCEEL04
0CREMOTO01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
160
Pressurized, STEEL, high-efficiency boiler, FOR BLOWN GAS BURNERS
CONTROL PANEL 620 ÷ 1.300 C 30
0QUADELE24
STANDARD
CONTROL PANEL 620 ÷ 1.300 PC 30
0QUADELE25
MULTIZONE
NB: The electric panel is supplied separately and must be assembled by the installing technician.
DIMENSIONS
MOD.
(1)
CONNECTIONS
H
H1
H2
H4
H6
H10
L
L2
P
P2
P3
P4
P5
P6
Øb
ØC
N1
N3
N4
N5
N6
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
DN/in DN/in DN/in
in
in
in
70
1030
855
415
911
415
54.5
750
700
1055
630
413
240
402
200-250
130
200
50
50
1”
1”
-
½”
80
1030
855
415
911
415
54.5
750
700
1055
630
413
240
402
200-250
130
200
50
50
1”
1”
-
½”
90
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
100
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
120
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
150
1080
905
440
961
440
54.5
800
750
1440
1000
513
475
452
200-250
160
250
50
50
1”
1”
-
½”
200
1080
905
440
961
440
54.5
800
750
1440
1000
513
475
452
200-250
160
250
50
50
1”
1”
-
½”
250
1180
1005
440
1061
440
54.5
800
750
1690
1250
513
725
452
200-250
160
250
50
50
1”
1”
-
½”
300
1180
1005
490
1061
490
54.5
900
850
1690
1295
523
700
467
200-250
180
250
65
65
1”
1”
-
1”½
350
1180
1005
490
1061
490
54.5
900
850
1940
1500
523
980
437
200-250
180
250
65
65
1”
1”
-
1”½
400
1190
1015
500
1095
500
50
940
890
1872
1502
600
850
422
230-280
225
250
80
80
1”
1”
1”¼(1)
1”½
500
1380
1205
610
1285
610
60
1160
1110
1950
1502
663
850
437
270-320
225
300
80
80
1”
1”¼
1”¼
1”½
620
1380
1205
610
1285
610
60
1160
1110
2240
1792
663
1150
427
270-320
225
300
80
80
1”
1”¼
1”¼
1”½
750
1510
1335
675
1417
675
60
1290
1240
2255
1753
704
1100
451
270-320
280
350
100
100
1”
1”¼
1”½
1”½
850
1510
1335
675
1417
675
60
1290
1240
2255
1753
704
1100
451
270-320
280
350
100
100
1”
1”¼
1”½
1”½
950
1510
1335
675
1417
675
60
1290
1240
2500
2003
704
1200
596
270-320
280
350
100
100
1”
1”¼
1”½
1”½
1020
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
1200
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
1300
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
One connection only
161
N2
ATMOSPHERIC BOILERS
ELECTRIC PANELS
Rodi Dual 1400÷3500 kW
➲
Two-star efficiency
➲
Electric panel for multi-zone management
➲
Working pressure 6 bar
Available heat outputs:
FROM
WARM COMFORT
162
1400 TO 3500 kW
kW
CALDAIE ATMOSPHERIC BOILERS
STEEL high-efficiency boiler, FOR BLOWN GAS BURNERS
• Flue gas pipes boiler body in steel with flame inversion
• Control and management electric panel (to be ordered separately) in the standard version (C) with two-stage
furnace • Operation with blown diesel and gas burners
burner control, heating circulation pump control,
• Front door with reversible opening
recirculation pump control, external hot water storage
• Rear door can be opened for inspecting and cleaning
pre-setting, operating and alarm signals; moreover the multi-zone version (PC) is equipped with a control for
flue gas pipes
three zone pumps
• Covering with round casing made of embossed
• Energy efficiency marking (92/42/EC)★★★
aluminium and high density rock wool mat-type insulation • Holder for control thermometer
max
min
L (mm)
H (mm)
P (mm)
Weight (empty boiler, kg.)
Heat output kW Model
Dimensions
Code
RODI DUAL 1400
CRPxxGNB1O
1400
700
1470
1746
2886
2665.00
RODI DUAL 1600
CRPxxGNB1Q
1600
800
1470
1746
2886
2665.00
RODI DUAL 1800
CRPxxGNB1S
1800
900
1470
1746
3096
2815.00
RODI DUAL 2000
CRPxxGNB2K
2000
1000
1600
1876
3220
3730.00
RODI DUAL 2400
CRPxxGNB2O
2400
1200
1600
1876
3480
3980.00
RODI DUAL 3000
CRPxxGNB3K
3000
1500
1870
2146
3480
5300.00
RODI DUAL 3500
CRPxxGNB3P
3500
1750
1870
2146
3935
5800.00
163
RODI DUAL 1400÷3500 kW
Ø b
Øc
Dimensions and connection centre distances
N1 Boiler flow N2 Boiler return N3 Equipment connection N4 Boiler filling/draining connection
N5 Safety bi-thermal valve(s) N6 Bulb holders N8 Control holder
ACCESSORIES Article
WARM COMFORT
Description
Code
Remote control for climatic control unit (temperature regulation)
Remote control for climatic control unit (all functions)
Article
Description
Code
0CREMOTO00
Climatic control unit kit for two-stage burners
0KITCEEL04
0CREMOTO01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
164
FLOOR STANDING STEEL BOILERS for gas or oil burners
CONTROL PANEL C 30
0QUADELE24
STANDARD
CONTROL PANEL PC 30
0QUADELE25
MULTIZONE
ATMOSPHERIC BOILERS
ELECTRIC PANELS
IMPORTANT: The control panel is supplied separately and must be assembled by the installer.
MOD.
DIMENSIONS
CONNECTIONS
H
H1
H2
H6
H10
L
L2
P
P2
P3
P4
P5
P6
Øb
ØC
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
1400
1746
1630
880
880
150
1470
1270
2886
2300
831
1300
755
350-400
320
400
150
150
1600
1746
1630
880
880
150
1470
1270
2886
2300
831
1300
755
350-400
320
400
150
1800
1746
1630
880
880
150
1470
1270
3096
2510
771
1850
475
450-500
320
400
2000
1876
1760
945
945
150
1600
1400
3220
2510
903
1550
767
450-500
360
2400
1876
1760
945
945
150
1600
1400
3480
2770
903
1950
627
450-500
3000
2146
2030
1080
1080
150
1870
1670
3480
2770
903
2050
527
3500
2146
2030
1080
1080
150
1870
1670
3935
3225
903
2050
982
165
N1
N2
N3
N4
N5
N6
in
in
in
1”
1”¼
1”½
½”
150
1”
1”¼
1”½
½”
150
150
1”
1”¼
1”½
½”
500
200
200
1”
1”¼
2”
½”
360
500
200
200
1”
1”¼
2”
½”
450-500
400
550
200
200
1”
1”¼
2”
½”
450-500
400
550
200
200
1”
1”¼
2”
½”
DN/in DN/in DN/in
Rodi Dual HR 70÷1300 kW
➲
Three-star efficiency
➲
Electric panel for multi-zone management
➲
Working pressure 6 bar
Available heat outputs:
FROM
WARM COMFORT
166
70 kW
TO
1300 kW
CALDAIE ATMOSPHERIC BOILERS
STEEL high-efficiency boiler, FOR BLOWN GAS BURNERS
• Flue gas pipes boiler body in steel with flame inversion furnace • Operation with blown gas burners • Holder for control thermometer • Energy efficiency marking (92/42/EC) ★★★
• Control and management electric panel (to be ordered separately) in the standard version (C) with two-stage burner control, heating circulation pump control, recirculation pump control, external hot water storage pre-setting, operating and alarm signals; moreover the multi-zone version (PC) is equipped with a control for three zone pumps
max
min
L (mm)
H (mm)
P (mm)
Weight (empty boiler, kg.)
CRSxxGNB70
70
35
750
1030
1055
222
RODI DUAL HR 80
CRSxxGNB80
80
40
750
1030
1055
222
RODI DUAL HR 90
CRSxxGNB90
90
45
750
1030
1195
266
RODI DUAL HR 100
CRSxxGNB1A
100
50
750
1030
1195
266
RODI DUAL HR 120
CRSxxGNB1C
120
60
750
1030
1195
266
RODI DUAL HR 150
CRSxxGNB1F
150
75
800
1080
1440
357
RODI DUAL HR 200
CRSxxGNB2A
200
100
800
1080
1440
357
RODI DUAL HR 250
CRSxxGNB2F
250
125
800
1180
1690
442
RODI DUAL HR 300
CRSxxGNB3A
300
150
900
1180
1690
489
RODI DUAL HR 350
CRSxxGNB3F
350
175
900
1180
1940
558
RODI DUAL HR 400
CRSxxGNB4A
400
200
940
1190
1872
600
RODI DUAL HR 500
CRSxxGNB5A
500
250
1160
1380
1950
871
RODI DUAL HR 620
CRSxxGNB6C
620
310
1160
1380
2240
981
RODI DUAL HR 750
CRSxxGNB7F
750
375
1290
1510
2255
1230
RODI DUAL HR 850
CRSxxGNB8F
850
425
1290
1510
2255
1230
RODI DUAL HR 950
CRSxxGNB9F
950
475
1290
1510
2500
1446
RODI DUAL HR 1020
CRSxxGNB1K
1020
510
1440
1660
2500
1880
RODI DUAL HR 1200
CRSxxGNB1M
1200
600
1440
1660
2500
1880
RODI DUAL HR 1300
CRSxxGNB1N
1300
650
1440
1660
2500
1880
KW power output Model
Code
RODI DUAL HR 70
167
Overall dimensions
RODI DUAL HR 70÷1300 kW Dimensions and connection centre distances
Ø c
Øb
241
N1 Boiler flow N2 Boiler return N3 Equipment connection N4 Boiler filling/draining connection
N5 Safety bi-thermal valve(s) N6 Bulb holders N8 Control holder
ACCESSORIES Article
WARM COMFORT
Description
Code
Remote control for climatic control unit (temperature regulation)
Remote control for climatic control unit (all functions)
Article
Description
Code
0CREMOTO00
Climatic control unit kit for two-stage burners
0KITCEEL04
0CREMOTO01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
168
FLOOR STANDING STEEL BOILERS for gas burners
ELECTRIC PANELS CONTROL PANEL C 30
0QUADELE24
STANDARD
CONTROL PANEL PC 30
0QUADELE25
MULTIZONE
MOD.
(1)
DIMENSIONS
ATMOSPHERIC BOILERS
NB: The electric panel is supplied separately and must be assembled by the installing technician.
CONNECTIONS
H
H1
H2
H4
H6
H10
L
L2
P
P2
P3
P4
P5
P6
Øb
ØC
N1
N4
N5
N6
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
DN/in DN/in DN/in
in
in
in
70
1030
855
415
911
415
54.5
750
700
1055
630
413
240
402
200-250
130
200
50
50
1”
1”
-
½”
80
1030
855
415
911
415
54.5
750
700
1055
630
413
240
402
200-250
130
200
50
50
1”
1”
-
½”
90
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
100
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
120
1030
855
415
911
415
54.5
750
700
1195
755
513
265
417
200-250
130
200
50
50
1”
1”
-
½”
150
1080
905
440
961
440
54.5
800
750
1440
1000
513
475
452
200-250
160
250
50
50
1”
1”
-
½”
200
1080
905
440
961
440
54.5
800
750
1440
1000
513
475
452
200-250
160
250
50
50
1”
1”
-
½”
250
1180
1005
440
1061
440
54.5
800
750
1690
1250
513
725
452
200-250
160
250
50
50
1”
1”
-
½”
300
1180
1005
490
1061
490
54.5
900
850
1690
1295
523
700
467
200-250
180
250
65
65
1”
1”
-
1”½
350
1180
1005
490
1061
490
54.5
900
850
1940
1500
523
980
437
200-250
180
250
65
65
1”
1”
-
1”½
400
1190
1015
500
1095
500
50
940
890
1872
1502
600
850
422
230-280
225
250
80
80
1”
1”
1”¼(1)
1”½
500
1380
1205
610
1285
610
60
1160
1110
1950
1502
663
850
437
270-320
225
300
80
80
1”
1”¼
1”¼
1”½
620
1380
1205
610
1285
610
60
1160
1110
2240
1792
663
1150
427
270-320
225
300
80
80
1”
1”¼
1”¼
1”½
750
1510
1335
675
1417
675
60
1290
1240
2255
1753
704
1100
451
270-320
280
350
100
100
1”
1”¼
1”½
1”½
850
1510
1335
675
1417
675
60
1290
1240
2255
1753
704
1100
451
270-320
280
350
100
100
1”
1”¼
1”½
1”½
950
1510
1335
675
1417
675
60
1290
1240
2500
2003
704
1200
596
270-320
280
350
100
100
1”
1”¼
1”½
1”½
1020
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
1200
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
1300
1660
1485
750
1568
750
60
1440
1390
2500
2003
704
1200
596
270-320
280
400
125
125
1”
1”¼
1”½
1”½
One connection only
169
N2
N3
Rodi Dual HR 1400÷3500 kW
➲
Three-star efficiency
➲
Electric panel for multi-zone management
➲
Working pressure 6 bar
Available heat outputs:
FROM
WARM COMFORT
170
1400 TO 3500 kW
kW
CALDAIE ATMOSPHERIC BOILERS
STEEL high-efficiency boiler, FOR BLOWN GAS BURNERS
• Flue gas pipes boiler body in steel with flame inversion
• Control and management electric panel (to be ordered
furnace
separately) in the standard version (C) with two-stage
• Operation with blown gas burners
burner control, heating circulation pump control, recir-
• Front door with reversible opening
culation pump control, external hot water storage pre-
• Rear door can be opened for inspecting and cleaning
setting, operating and alarm signals; moreover the multi-
flue gas pipes
zone version (PC) is equipped with a control for three
• Covering with round casing made of embossed alumi-
zone pumps
nium and high density rock wool mat-type insulation
• Energy efficiency marking (92/42/EC) ★★★
• Holder for control thermometer
KW power output
Overall dimensions
max
min
L (mm)
H (mm)
P (mm)
Weight (empty boiler, kg.)
CRSxxGNB1O
1400
700
1470
1746
2886
2665
RODI DUAL HR 1600
CRSxxGNB1Q
1600
800
1470
1746
2886
2665
RODI DUAL HR 1800
CRSxxGNB1S
1800
900
1470
1746
3096
2815
RODI DUAL HR 2000
CRSxxGNB2K
2000
1000
1600
1876
3220
3730
RODI DUAL HR 2400
CRSxxGNB2O
2400
1200
1600
1876
3480
3980
RODI DUAL HR 3000
CRSxxGNB3K
3000
1500
1870
2146
3480
5300
RODI DUAL HR 3500
CRSxxGNB3P
3500
1750
1870
2146
3935
5800
Model
Code
RODI DUAL HR 1400
171
RODI DUAL HR 1400÷3500 kW
Ø b
Øc
Dimensions and connection centre distances
N1 Boiler flow N2 Boiler return N3 Equipment connection N4 Boiler filling/draining connection
N5 Safety bi-thermal valve(s) N6 Bulb holders N8 Control holder
ACCESSORIES Article
WARM COMFORT
Description
Code
Remote control for climatic control unit (temperature regulation)
Remote control for climatic control unit (all functions)
Article
Description
Code
0CREMOTO00
Climatic control unit kit for two-stage burners
0KITCEEL04
0CREMOTO01
Temperature probe for climate control unit and control panels (KF/SPF)
0SONDASO00
172
FLOOR STANDING STEEL BOILERS for gas burners
control panel C 30
0QUADELE24
STANDARD
control panel PC 30
0QUADELE25
MULTIZONE
IMPORTANT: The control panel is supplied separately and must be assembled by the installer.
MOD.
DIMENSIONS
CONNECTIONS
H
H1
H2
H6
H10
L
L2
P
P2
P3
P4
P5
P6
Øb
ØC
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
mm
1400
1746
1630
880
880
150
1470
1270
2886
2300
831
1300
755
350-400
320
400
150
150
1600
1746
1630
880
880
150
1470
1270
2886
2300
831
1300
755
350-400
320
400
150
1800
1746
1630
880
880
150
1470
1270
3096
2510
771
1850
475
450-500
320
400
2000
1876
1760
945
945
150
1600
1400
3220
2510
903
1550
767
450-500
360
2400
1876
1760
945
945
150
1600
1400
3480
2770
903
1950
627
450-500
3000
2146
2030
1080
1080
150
1870
1670
3480
2770
903
2050
527
3500
2146
2030
1080
1080
150
1870
1670
3935
3225
903
2050
982
173
N1
N2
N3
N4
N5
N6
in
in
in
1”
1”¼
1”½
½”
150
1”
1”¼
1”½
½”
150
150
1”
1”¼
1”½
½”
500
200
200
1”
1”¼
2”
½”
360
500
200
200
1”
1”¼
2”
½”
450-500
400
550
200
200
1”
1”¼
2”
½”
450-500
400
550
200
200
1”
1”¼
2”
½”
DN/in DN/in DN/in
ATMOSPHERIC BOILERS
ELECTRIC PANELS
STANDARD BOILERS
ATMOSPHERIC BOILERS
BURNERS
175
Pyrós Dual 1G - Pyrós 1G • Engineered for low- and medium-pressurized boilers • External adjustment of combustion head and air intake • Sound-proofed casing • Insulating screen Range • Pyrós Dual 1 GTFR diesel oil-fired blown burner, fitted with a 55 W pre-heater • Pyrós Dual 1 GTF / Pyrós 1 GTF diesel oil-fired blown burner
Model
Code
Heat output kW
Gross weight (kg.)
PYRÓS DUAL 1 GTFR 3
BPBI00A327
26.6
13.50
PYRÓS DUAL 1 GTFR 4
BPBI00A338
36.3
13.50
PYRÓS DUAL 1 GTF 5
BPBI00A550
47.2
13.50
PYRÓS 1 GTF 6
BPGxx0D660
57.6
19.00
PYRÓS 1 GTF 7
BPGxx0D770
68.6
19.00
PYRÓS 1 GTF 8
BPGxx0D885
80.6
19.00
Dimensions and connection centre distances PYRÓS DUAL 1 GTFR 3 - GTFR 4 - GTF 5
PYRÓS 1 GTF 6 - GTF 7 - GTF 8
PYROS DUAL 1G OPERATING RANGE
GTFR 3 GTFR 4 GTF 5
Combustion chamber pressure (mbar)
Combustion chamber pressure (mbar)
PYROS DUAL 1G OPERATING RANGE
Output (KW)
Output (KW)
WARM COMFORT
176
DIESEL- oil burners
PYRÓS DUAL 1 GTFR 3
Fuel
-
Heat output range Pre-adjustment heat output Nozzle: brand / type Nozzle
PYRÓS DUAL 1 GTF 5
diesel-oil: viscosity = 1.4°E. Hi= 42.7 MJ/kg (10200 kcal/kg) T= 20°C
kW (kg/h)
19 ÷ 33.5 (1.6 ÷ 2.8)
kW
26.6
USgal/h
Nozzle: angle / cone
PYRÓS DUAL 1 GTFR 4 21.4 ÷ 41.5 (1.8 ÷ 3.5)
33.2 ÷ 53.4 (2.8 ÷ 4.5)
36.3
47.2
Delavan W. B - Steinen Q - Danfoss S 0.65
-
0.85 60°W
1.00 60°B
Diesel-oil consumption (± 4%)*
kg/h
2.3
Diesel-oil calibration pressure*
bar
12.5
12
12
-
3
4.6
3.8
Combustion head calibration*
-
fixed
fixed
fixed
CO2 content*
%
Air calibration*
Maximum counterpressure*
3.1
4
12.5
Pa
370
320
300
Combustion head diameter (B)
mm
89
89
89
Combustion head length (A)
mm
86
86
86
Pump pressure range
bar
(Maximum) pump depression
bar
Diesel-oil pre-heater
W
Electrical power supply
8 ÷ 15 -0.4 55
-
55
-
single stage 230 V - 50 Hz
Motor condenser
μF
4.5
4.5
4.5
Power absorption
kW
0.215
0.215
0.16
Motor current
A
0.7
0.7
0.7
Electrical protection
-
IP 40
* IMPORTANT: the reported values and features refer to the burner pre-adjustment values. PYRÓS 1 GTF 6
TECHNICAL SPECIFICATIONS Fuel Heat output range Pre-adjustment heat output Nozzle: brand / type Nozzle
-
PYRÓS 1 GTF 7
PYRÓS 1 GTF 8
diesel-oil: viscosity = 1.4°E. Hi= 42.7 MJ/kg (10200 kcal/kg) T= 20°C
kW (kg/h)
55.7÷113 (4.7 ÷ 9.5)
kW
57.6
-
55.7÷113 (4.7 ÷ 9.5)
55.7÷113 (4.7 ÷ 9.5)
68.6
80.6
Delavan W. B - Steinen Q - Danfoss S
USgal/h
1.10
1.35
1.65
-
60°B
60°B
60°B
Diesel-oil consumption (± 4%)*
kg/h
4.86
5.8
6.8
Diesel-oil calibration pressure*
bar
12
11
11
-
3.2
4.5
5.75
Combustion head calibration*
-
2.0
2.5
2.5
CO2 content*
%
Nozzle: angle / cone
Air calibration**
Maximum counterpressure*
12.5
Pa
125
115
110
Combustion head diameter (B)
mm
105
105
105
Combustion head length (A)
mm
111
111
111
Pump pressure range
bar
(Maximum) pump depression
bar
-0.4
-
single stage 230 V - 50 Hz
Electrical power supply
8 ÷ 15
Motor condenser
μF
5
5
5
Power absorption
kW
0.160
0.160
0.160
Motor current
A
1.3
1.3
1.3
Electrical protection
-
IP 40
*IMPORTANT: the reported values and features refer to the burner pre-adjustment values. 177
ATMOSPHERIC BOILERS
TECHNICAL SPECIFICATIONS
Pyrós 1M • Methane (G20) or LPG-fired • Gravitational fully closing air damper while at rest • Sound-proofed casing
Model
Code
PYRÓS 1 MTF 50 PYRÓS 1 MTF 100
METHANE
BPMxx2E650
LPG
BPMxx3E650
METHANE
BPMxx2E91A
LPG
BPMxx3E91A
Pre-adjustment output kW
Gross weight Kg:
18 ÷ 52
15.00
46 ÷ 93
15.00
GAS TRAIN* Model
Code
Coupling
Gross weight Kg.
MB - DLE 403
0RAMPGAS00
PYRÓS 1 MTF 50
1.70
MB - DLE 405
0RAMPGAS01
PYRÓS 1 MTF 50
3.00
MB - DLE 407
0RAMPGAS02
PYRÓS 1 MTF 100
3.10
*Class A Group 2 gas trains, complying with EN 88 and EN 161 Standards. Fitted with: gas filter, minimum gas pressure switch, safety valve, pressure stabilizer, single-stage adjusting valve.
Dimensions and connection centre distances
Mod. MTF 50
Mod. MTF 100
WARM COMFORT
A
B
C
D
E
249
285
186
138
91
F
G
H
I
L
100
303
96
170
140
A
B
C
D
E
275
326
208
142
105
F
G
H
I
L
110
355
123
185
160
Combustion chamber pressure (mbar)
PYROS DUAL 1M OPERATING RANGE
OUTPUT (KW)
178
TECHNICAL SPECIFICATIONS
PYRÓS 1 MTF 50
PYRÓS 1 MTF 100
kW kcal/h
18 ÷ 52 15.480 ÷ 44.720
46 ÷ 93 39.560 ÷ 79.980
G 20
G 20
MJ/m3 kcal/m3 kg/m3
34.02 8127 0.68
34.02 8127 0.68
Maximum flow rate**
m3/h
5.38
9.6
Gas pressure at maximum output
mbar
4.5
Heat input* Type of gas Heating value** Density****
Electrical power supply
4.6 50 Hz ~ 230 V
Electric motor: starting current
A
2.2
2.6
Electric motor: running current
A
0.64
0.77
557 SE
557 SE
Control appliance Electrical power
W
Electrical protection Sound pressure
dBA
Gas train coupling diameter
150
180
IP 40
IP 40
58
63
G½
G¾
* Reference conditions: room temperature 20 °C - 1013 mbar. ** Standard reference conditions: temperature 15 °C - 1013 mbar. GAS TRAINS Model
Connection diameter
Minimum gas pressure, mbar
Coupling to boilers
Gas supply
Burner
MB-DLE 403
G½
G½
10
PYRÓS 1 MTF 50
MB-DLE 405
G½
G½
10
PYRÓS 1 MTF 50 PYRÓS 1 MTF 100
MB-DLE 407
G½
G½
10
PYRÓS 1 MTF 100
GAS DI TRAIN LOADRAMPE LOSS GAS PERDITA CARICO FOR PER PYRÓS PYRÓSMTF MTF50 50
GAS TRAIN LOAD RAMPE LOSS GAS PERDITA DI CARICO FOR 100 PERPYROS PYRÓSMTF MTF 100
Gas train + combustion head load loss.
Combustion head load loss.
179
ATMOSPHERIC BOILERS
gas burners
Boiler and burner coupling BoilerS and oil-fired burnerS coupling
ELBA DUAL
BURNER MODEL
BURNER TY PE
Code
ELBA DUAL 23
PYRÓS DUAL 1 GTFR 3
SINGLE STAGE
BPBI00A327
ELBA DUAL 31
PYRÓS DUAL 1 GTFR 4
SINGLE STAGE
BPBI00A338
ELBA DUAL 33
PYRÓS DUAL 1 GTFR 4
SINGLE STAGE
BPBI00A338
ELBA DUAL 43
PYRÓS DUAL 1 GTF 5
SINGLE STAGE
BPBI00A550
ELBA DUAL 53
PYRÓS 1 GTF 6
SINGLE STAGE
BPGxx0D660
ELBA DUAL 63
PYRÓS 1 GTF 7
SINGLE STAGE
BPGxx0D770
ELBA DUAL 73
PYRÓS 1 GTF 8
SINGLE STAGE
BPGxx0D885
WARM COMFORT
180
ELBA DUAL
ELBA DUAL 23
ELBA DUAL 31
ELBA DUAL 33
BURNER MODEL
BURNER TYPE
Code
GAS TRAIN Model
MIN. PRESSURE (mbar)
Code
-
-
-
-
-
-
PYRÓS 1 MTF 50
PYRÓS 1 MTF 50
BPMxx2E650
MB - DLE 403
9
0RAMPGAS00
BPMxx3E650
MB - DLE 405
7
0RAMPGAS01
BPMxx2E650
MB - DLE 403
9
0RAMPGAS00
BPMxx3E650
MB - DLE 405
7
0RAMPGAS01
MB - DLE 405
7
0RAMPGAS01
BPMxx2E91A
MB - DLE 405
10
0RAMPGAS01
BPMxx3E91A
MB - DLE 407
8
0RAMPGAS02
BPMxx2E91A
MB - DLE 405
10
0RAMPGAS01
BPMxx3E91A
MB - DLE 407
8
0RAMPGAS02
BPMxx2E91A
MB - DLE 405
12
0RAMPGAS01
BPMxx3E91A
MB - DLE 407
10
0RAMPGAS02
SINGLE STAGE
SINGLE STAGE
BPMxx2E650 ELBA DUAL 43
PYRÓS 1 MTF 50
SINGLE STAGE BPMxx3E650
ELBA DUAL 53
ELBA DUAL 63
ELBA DUAL 73
PYRÓS 1 MTF 100
PYRÓS 1 MTF 100
PYRÓS 1 MTF 100
SINGLE STAGE
SINGLE STAGE
SINGLE STAGE
181
ATMOSPHERIC BOILERS
BoilerS and gas-fired burnerS coupling
ACCESSORIES Ø 60 ducts
Ø 80 mm ducts
for condensing boilers Description
and accessories Description
Code
Code
Ø 60 flexible pipe centering device
0CENTFLE02
Ø 80 mm, 1 m long duct (TFS boilers)
0CONDOTT00
Ø 60, 90° M/F elbow
0CURVAXX16
Ø 80 mm, 0.5 metre long duct (TFS boilers)
0CONDOTT01
Ø 60, 45° M/F elbow
0CURVAXX17
Ø 80 mm, 90° wide radius elbow (TFS boilers)
0CURRALA00
Ø 60 m/f, 1 m extension
0PROLUNG16 0PROLUNG17
Ø 80 mm, 90° narrow radius elbow (TFS boilers)
0CURRAST00
Ø 60 m/f, 2 m extension Ø 60 m/f, 0.5 m extension
0PROLUNG18
Ø 80 mm, 45° elbow (TFS boilers)
0CURVAXX00
Ø 60, M/M/F “T” coupling
0RACCORT06
Ø 80 mm, 90° narrow radius elbow With inspection opening (TFS boilers)
0CURVAXX03
Ø 80/60 REDUCER
0RIDUZIO19
Ø 60 condensate drain kit
0SCARCON03
Ø 80 mm, 30 mm high, air intake AISI316 stainless steel grille (TFS boilers)
0GRIASIN00
Ø 60, 1 m air intake terminal
0TERMASP01
External protection grille
0GRIPRES00
Ø 60, 1 m flue gas duct terminal
0TERMSCA01
Ø 80 mm double lipped seal
0GUADOLA02
0TUBOFLE05
Ø 80 mm condensate trap (TFS boilers)
0RACCOOR00
Silicone wall rose (internal Ø 80 mm / external Ø 170 mm)
0ROSPASI00
Ø 80 mm stainless steel anti-wind terminal (TFS boilers)
0TERCOIN00
Ø 80 stainless steel roof terminal
0TERCOIN02
Ø 60, M/F flexible pipe, 20 m roll
Ø 60/100 ducts
for condensing boilers Description
Code
Coaxial kit Ø 60/100, 0.75 m
0CONDASP00
Ø 80 mm stainless steel “Chinese” terminal (TFS boilers)
0TERMCIN00
Ø 60/100, 45° M/F elbow
0CURVAXX04
Ø 80 mm vertical chimney terminal
0TESTCAM00
Ø 60/100, 90° M/F elbow
0CURVAXX05
Ø 80 mm, 132 mm long vertical stub pipe (TFS boilers)
0TRONCMF00
Ø 60/100 coaxial chimney kit
0KCAMASP00
Ø 60/100, 90° elbow and flange kit
0KCURFLA00
Ø 80 mm, 135 mm long, vertical stub pipe with condensate colleCTOR (TFS BOIlers)
0TRONVER00
Ø 60/100 coaxial connection kit
0KITATCO00
Ø 60/100, 1 m M/F coaxial extension
0PROLUNG02
Ø 60/100, 0.5 m M/F coaxial extension
0PROLUNG03
Ø 160 ducts
for cascade condensing systems Description
Ø 80 ducts
for condensing boilers Description
Code
Code
Ø 160 flue gas collector
0COLLFUM00
Ø 160, 90°, M/F elbow
0CURVAXX12
Ø 160, 45°, M/F elbow
0CURVAXX14 0PROLUNG10
Ø 80 flexible pipe centering device
0CENTFLE00
Ø 160, 1 m M/F extension
Ø 80, 45° M/F elbow
0CURVAXX01
0PROLUNG11
Ø 80, 90° M/F elbow
0CURVAXX02
Ø 160, 0.785 m M/F extension (for flue gas collector connection, boilers with cabinet)
Ø 80 air-intake grille
0GRIGASP01
0PROLUNG12
Ø 80 seal for flexible pipe
0GUATRLA00
Ø 160, 0.475 m M/F extension (for flue gas collector connection, boilers without cabinet)
Ø 80 “T” coupling kit for inspection and condensate collection
0KITRACT00
Ø 160, M/M/F, “T” coupling
0RACCORT04
Ø 80+80 Split ducts kit
0KITSDOP00
Ø 160 cap kit for flue gas collector (with possibility of condensate drain)
0SCARCON01
Ø 80 M/F telescopic extension (0.34÷0.45 m)
0PROLTEL01
Condensate drain syphon (horizontal coupling)
0SIFCOND00
Ø 80, 1 m extension
0PROLUNG00
0SIFCOND01
Ø 80, 0.5 m extension
0PROLUNG01
Condensate drain syphon (vertical coupling)
Ø 80, M/M/F “T” coupling
0RACCORT00
Ø 80, 1 m flue gas duct terminal
0TERMSCA00
Ø 80, M/F flexible pipe (without seals) 20 m roll
0TUBOFLE01
WARM COMFORT
182
Ø 100 ducts
Ø 100/60 mm coaxial
ducts
Description
Description Ø 100 flexible pipe centering device
0CENTFLE01
Ø 100, 90°, M/F elbow with inspection opening
0CURVAXX08
Ø 100, M/F 90° elbow
0CURVAXX10
Code
Ø 100/60 mm vertical coaxial coupling (TFS boilers)
0ATTCOVE00
Ø 100/60 mm vertical coaxial coupling with condensate collection (TFS boilers)
0ATTCOVE02
Ø 100, M/F 45° elbow
0CURVAXX11
Ø 100, M/F, 0.5 m extension
0PROLUNG07
Ø 100/60, mm 90° coaxial elbow with flange (TFS boilers)
0CURCOFL00
Ø 100, M/F, 1 m extension
0PROLUNG08
Ø 100/60, mm 90° coaxial elbow (TFS boilers)
0CURVCON00
Ø 100, M/F, 2 m extension
0PROLUNG09
Ø 100/60, mm 45° coaxial elbow (TFS boilers)
0CURVCON01
Ø 100, M/M/F “T” coupling
0RACCORT01
Ø 100 band for coaxial kits
Ø 100, M/M/F “T” coupling kit for visual inspection and condensate drain
0RACCORT02
Ø 60 mm or Ø 100 mm double lipped seal
Ø 100, M/M/F “T” coupling kit for visual inspection
0RACCORT03
Ø 80/100 reducer
0RIDUZIO13
Ø 100/60 mm, 1 m type “A” coaxial kit (TFS boilers)
0KITCONC00
0SCARCON00
Ø 100/60 mm, 0.75 m type “A” coaxial kit (TFS boilers)
0KITCONC01
0SIFCOND00
Ø 100/60 mm, 0.5 m type “C” coaxial kit (TFS boilers)
0KITCONC02
Condensate drain syphon (vertical coupling)
0SIFCOND01
Ø 100/60 mm, 0.5 m type “A” coaxial kit (TFS boilers)
0KITCONC03
Ø 100 roof terminal
0TERCOIN01
Ø 100 condensate drain kit Condensate drain syphon (horizontal coupling)
Ø 100, 1 m air intake terminal
0TERMASP00
Ø 100, 1 m flue gas duct terminal
0TERMSCA03
Ø 100, 140 mm, M/F vertical stub pipe with inspection opening
0TROSCAF01
Ø 100, flexible pipe (without seals) 20 m roll
0TUBOFLE04
0FASCETT04 0GUADOLA00 0GUADOLA01
0KITTACA00
Air intake blanking cap kit (TFS boilers)
0ROSONEX00
Ø 100 external rose
0ROSONEX01
Ø 100 internal rose Ø 100/60 mm, 0.5 or 1 m type “C” coaxial kit (TFS boilers)
(1 m.)
0TUBCOLU00
(0.5 m.)
0TUBCOLU01
Chimneys
and accessories Description
Ø 200 ducts
for cascade condensing systems Description
Code
Code
Ø 80/80 mm chimney for split flue gas duct (TFS boilers)
0CAMCOSD00
Kit of flexible stainless steel-coated pipes N° 2 x ¾” - N° 3 x ½” L: 260/520 mm
0KITIDTR00 0KITSCAR00
Ø 200 flue gas collector
0COLLFUM01
surge arrester
Ø 200, 90°, M/F elbow
0CURVAXX13
Ø 200, 45, M/F elbow
0CURVAXX15
Vertical flue gas duct kit with chimney, from Ø 100/60 to Ø 80 mm (TFS boilers)
0KVERCAM01
Ø 200, 1 m M/F extension
0PROLUNG13
0SCATECO00
Ø 200, 0.785 m M/F extension (for flue gas collector connection, boilers with cabinet)
Ø 100/60 mm coaxial roof flue gas duct (TFS boilers)
0PROLUNG14
Tile for descending roof (flue gas terminal)
0TEGTEIN00
Ø 200, 0.475 m M/F extension (for flue gas collector connection, boilers without cabinet)
Tile for flat roof (flue gas terminal)
0TEGTEPI00
0PROLUNG15
Ø 200, M/M/F, “T” coupling
0RACCORT05
Ø 200 cap kit for flue gas collector (with possibility of condensate drain)
0SCARCON02
Condensate drain syphon (horizontal coupling)
0SIFCOND00
Condensate drain syphon (VERTICAL coupling)
0SIFCOND01
electromechanical ambient thermostat
0TERAMEL00
300b weekly/daily ambient chronothermostat
0CROAMSE00
Ø 80 chimneys
for condensing boilers Description
183
Code
Ø 80+80 air intake/flue gas duct chimney (height 1384 mm)
0CAMIASP00
Ø 80 flue gas discharge chimney (height 1380 mm)
0CAMISCA00
ACCESSORIES
for condensing boilers
HOT WATER
SYSTEM COMPONENTS
STORAGES
185
WHPF BM
SINGLE COIL WATER HEATERS WITH 3-WAY VALVE
➲
Easy installation
➲
High efficiency and low operating costs
➲
Can be integrated with solar systems
➲
Supply of abundant and continuous water
Available with the following capacity:
120 Litres
WARM COMFORT
186
150
200
Litres
Litres
WHPF BM 120
WHPF BM 150
WHPF BM 200
AVBMxx0120
AVBMxx0150
AVBMxx0200
litres
120
150
200
Coil power
kW
29
38
49
Gross weight
Kg.
72.40
82.80
94.00
Code Capacity
• Porcelain-glass internal coating as per DIN 4753 • External insulation in high density ecological polyurethane foam • External case in metal sheet • ABS cover with: - Motorised three-way valve - Regulation thermostat - Magnesium anode - Thermometer - Safety valve • Dimensions (mm): -mod. BM 120 H 1055 - Ø 560 -mod. BM 150 H 1205 - Ø 560 -mod. BM 200 H 1480 - Ø 560 Options: 5l expansion tank (0KVASEBO00) that can be housed in the hot water storage.
ACCESSORIES Article
Description
Code
5 litre expansion vessel kit
0KVASEBO00
187
SYSTEM COMPONENTS
HOT WATER STORAGES
WHPF BO
SINGLE COIL HOT WATER HEATERS
Hot water storage made of stainless steel
➲
Easy installation
➲
High efficiency and low operating costs
➲
Can be integrated with solar systems
Available with the following capacity:
120 Litres
WARM COMFORT
188
Code Flow rate
WHPF BO 120 WHITE
WHPF BO 120 GREY
AOBOxxB120
AOBOxxG120
120
120
BALI R
ELBA DUAL / CAPRI R
68.80
68.80
litres
Coupling Gross weight
Kg.
• Horizontal AISI 316 L stainless steel hot water storage with 120 litres capacity • Insulation in expanded polyurethane • Base plate with adjustable supporting feet • DHW thermometer • Regulation thermostat • Dimensions (mm): H 650 x L 600 x P 796
NOTE: the hot water storage can stand a maximum weight of 250 Kg.
ACCESSORIES Article
Description
Code
Hydraulic kit for connection to boilers Elba Dual and Bali R
0KITPOVA03
Hydraulic kit with pump and expansion vessel for boilers Elba Dual and Bali R
0KITPOVA05
189
SYSTEM COMPONENTS
HOT WATER STORAGES
WHPS BA SS
SINGLE COIL HOT WATER STORAGE
➲
Easy installation
➲
High efficiency and low operating costs
➲
Supply of abundant and continuous water
➲
Can be integrated with solar systems
Available with the following capacity:
FROM
WARM COMFORT
190
200 TO 2000 Litres
Litres
HOT WATER STORAGES
WHPS BA 200 SS
WHPS BA 300 SS
WHPS BA 500 SS
WHPS BA 1000 SS
WHPS BA 2000 SS
Capacity
litres
200
300
500
1000
2000
Maximum working pressure
bar
10
10
10
10
10
Maximum working temperature
°C
95
95
95
95
95
Coil area
m2
1
1.4
2.1
4
4.5
Coil power (ΔT 35 K)
kW
30
44
55
120
135
Overall height
mm
1329
1560
1818
2120
2315
Outer diameter
mm
610
650
760
1000
1400
Outer diameter without insulation
mm
-
-
-
800
1200
mm
1465
1690
1966
2250
2705
mm
50
50
55
100
100
Gross weight
Kg.
90.00
115.00
140.00
245.00
450.00
PSBOLLV054
PSBOLLV055
PSBOLLV056
0BOLLITO17
0BOLLITO22
Code
SYSTEM COMPONENTS
Tilting height Insulation thickness
• Porcelain-glass-coated steel hot water storage with single coil • External case in white skay • Insulation in stiff expanded polyurethane, CFC and HCFC free (soft expanded polyurethane for 1000 and 2000 litre capacity) • Magnesium protection anode for 200 - 300 - 500 - 1000 litre capacity • Protection electrodes with electronic device for 2000 litre capacity • DHW thermometer (standard for 200 - 300 - 500 models), other models are preset (G ½ fitting) • Two holders for temperature probes (standard for models 200 - 300 - 500), other models are preset for one holder (G ½ fitting) • Ready for resistor with G 1 ½ fitting for 1000 - 2000 models • Front inspection flange
ACCESSORIES Article
Description
Code
Single-electrode electronic anode (mod. 200, 300, 500, 1000)
0ANOELET01
Thermometer and thermostat kit (mod. 200, 300, 500, 1000 and 2000)
0KTERMTE00
Resistor with G1 ½ thread and single-phase/three-phase power supply (mod. 200, 300, 500, 1000 and 2000) Single-phase power supply and flanged resistor (mod. 200, 300 and 500)
191
3 kW
PSRESELE02
4.5 kW
PSRESELE03
3 kW
PSRESELE13
WHPS PU S
CENTRAL HEATING BUFFER TANK
➲
Easy installation
➲
High efficiency and low operating costs
➲
Can be integrated with solar systems
Available with the following capacity:
WARM COMFORT
192
1000
2000
3000
Litres
Litres
Litres
WHPS PU 1000 S
WHPS PU 2000 S
WHPS PU 3000 S
Total capacity
litres
1000
2000
3000
Working pressure
bar
3
3
3
Maximum working temperature
°C
95
95
95
Coil maximum working pressure
bar
10
10
10
Coil maximum temperature
°C
110
110
110
Coil surface
m2
3
4.2
4.2
Coil heat output (80/60)
kW
90
120
120
Overall height
mm
2080
2195
2750
Outer diameter
mm
990
1400
1450
Outer diameter without insulation
mm
790
1200
1250
Tilting height without insulation
mm
2280
2710
2985
Insulation thickness
mm
100
100
100
kg
180.00
330.00
430.00
PSBOLLV014
PSBOLLV015
PSBOLLV016
Gross weight Code
• Steel puffer, with coil. • Ready for: control probes and CH couplings. • Insulation in stiff expanded polyurethane, CFC and HCFC free • External case in white skay.
193
SYSTEM COMPONENTS
HOT WATER STORAGES
WHPS BA DS
DOUBLE COIL WATER HEATERS FOR SOLAR SYSTEMS
➲
Easy installation
➲
High efficiency and low operating costs
➲
Supply of abundant and continuous water
➲
Can be integrated with solar systems
Available with the following capacity:
FROM
WARM COMFORT
194
200 TO 2000 Litres
Litres
HOT WATER STORAGES
Capacity
litres
200
300
500
1000
2000
Maximum working pressure
bar
10
10
10
10
10
Maximum working temperature
°C
95
95
95
95
95
Solar coil maximum temperature
°C
110
110
110
110
110
Auxiliary coil area
m2
0.5
0.9
0.9
1.6
2
Solar coil area
2
m
0.7
1.4
2.1
3.4
4.5
Coil power (ΔT 35 K)
kW
22
31.5
31.5
42
57
Solar coil power (ΔT 35 K)
kW
25.5
44
63
98
135
Overall height
mm
1330
1560
1820
2120
2315
Outer diameter
mm
610
650
760
1000
1400
Outer diameter without insulation
mm
-
-
-
800
1200
Tilting height
mm
1465
1690
1970
2250
2600
Insulation thickness
mm
50
50
55
100
100
Gross weight
Kg.
95.00
130.00
150.00
260.00
480.00
PSBOLLV050
PSBOLLV051
PSBOLLV052
PSBOLLV005
PSBOLLV018
Code
• Porcelain-glass-coated steel hot water storage with double coil for solar installations • External case in white skay • Insulation in stiff expanded polyurethane, CFC and HCFC free (soft expanded polyurethane for 1000 and 2000 litre capacity) • Magnesium protection anode for 200 - 300 - 500 - 1000 litre capacity • Protection electrodes with electronic device for 2000 litre capacity • DHW thermometer (standard for 200 - 300 - 500 models), other models are preset (G ½ fitting) • Three holders for temperature probes (standard for models 200 - 300 - 500), other models are preset for two holders (G ½ fitting) • Ready for DHW recirculation • Ready for resistor with G 1 ½ fitting for 1000 - 2000 models • Front inspection flange
ACCESSORIES Article
Description
Code
Single-electrode electronic anode (mod. 200, 300, 500, 1000)
0ANOELET01
Thermometer and thermostat kit (mod. 200, 300, 500, 1000 and 2000)
0KTERMTE00
Resistor with G1 ½ thread and single-phase/three-phase power supply (mod. 200, 300, 500, 1000 and 2000) Single-phase power supply and flanged resistor (mod. 200, 300 and 500)
195
3 kW
PSRESELE02
4.5 kW
PSRESELE03
3 kW
PSRESELE13
SYSTEM COMPONENTS
WHPS BA 200 DS WHPS BA 300 DS WHPS BA 500 DS WHPS BA 1000 DS WHPS BA 2000 DS
WHPS BL SS
SINGLE COIL WATER HEATERS
➲
Easy installation
➲
High efficiency and low operating costs
➲
Fast storage with supply of abundant and continuous water
Available with the following capacity:
120 Litres
WARM COMFORT
196
HOT WATER STORAGES
Capacity
litres
120
Maximum working pressure
bar
8
Maximum working temperature
°C
95
Coil area
m2
1.4
Coil power (ΔT 35K)
kW
29
Overall height
mm
1055
Outer diameter
mm
560
Insulation thickness
mm
30
kg
65.00
Gross weight Code
PSBOLLV021
• Porcelain-glass-coated steel hot water storage with single coil for solar installations • External case in white metal sheet • Fitting trim in white ABS • Fittings at the top • Ready for discharge cock • Insulation in stiff expanded polyurethane, CFC and HCFC free • Magnesium protection anode • Holder for temperature probe • Upper inspection flange • DHW thermometer
197
SYSTEM COMPONENTS
WHPS BL 120 SS
WHPS DX
COMBI WATER HEATERS
➲
Easy installation
➲
High efficiency and low operating costs
➲
Supply of abundant and continuous water
➲
Can be integrated with solar systems
Available with the following capacity:
500 Litres
WARM COMFORT
198
1000
1500
Litres
Litres
WHPS DX 500/180
WHPS DX 1000/250
WHPS DX 1500/300
Total tank Capacity
litres
500
1000
1500
Volume of domestic hot water
litres
180
250
300
DHW maximum working pressure
bar
6
6
6
Hot water storage maximum working pressure
bar
3
3
3
Maximum working temperature
°C
95
95
95
Coil maximum temperature
°C
110
110
110
Coil area
m2
2.5
3
3.5
Coil power (ΔT 35K)
kW
75
90
105
Overall height
mm
1700
2030
2070
Outer diameter with insulation
mm
850
990
1200
Outside diameter without insulation
mm
650
790
1000
Tilting height without insulation
mm
1820
2180
2300
Insulation thickness
mm
100
100
100
Gross weight
Kg.
175.00
250.00
315.00
PSBOLLV023
PSBOLLV007
PSBOLLV008
Code
• Steel tank-in-tank hot water storage with coil and tank in porcelain-glasscoated steel for domestic hot water, for solar installations • Suitable for: one domestic water control probe, domestic water recirculation, three heating probes, heating water thermometer, nine multi-purpose connections (G1 ½ thread), auxiliary resistor (G1 ½ thread) • Upper DHW inspection flange • Insulation in soft expanded polyurethane, CFC and HCFC free • External case in white skay • Magnesium protection anode for the DHW tank
ACCESSORIES Article
Description Resistor with G1 ½ thread and single-phase/three-phase power supply (mod. 500/180, 1000/250, 1500/300)
199
Code 3 kW
PSRESELE02
4,5 kW
PSRESELE03
SYSTEM COMPONENTS
HOT WATER STORAGES
Heat distribution and metering modules “GEMINI”
GEMINI Satellite energy distribution and metering modules for centralized systems. Designed to set up systems for the centralized production of CH water and DHW. They can meter the energy supplied to each housing unit for heating and cooling purposes as well as the amount of domestic water used, either cold or hot. The module can be supplied with different configurations
to
cater
for
various
system
requirements. The range consists of modules for the management of heating (also mixed hot water) and modules for the management of heating and cooling. Possibility to fit another meter for non-domestic cold water and a thermostat unit for DHW.
WARM COMFORT
200
GEMINI C15-2A DZ SR SINGLE SUPPLY Description
Code HCGEMRTV08
Gemini C15-2A DZ SR
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC08
Metering module and meters
HCGEMRCO08
GEMINI C15-2A DZ Description
Code HCGEMRTV14
Gemini C15-2A DZ
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC14
Metering module and meters
HCGEMRCO14
GEMINI C25-2A DZ SR SINGLE SUPPLY Description Gemini C25-2A DZ SR
Code HCGEMRTV09
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC09
Metering module and meters
HCGEMRCO09
GEMINI C25-2A DZ SINGLE SUPPLY Description Gemini C25-2A DZ
Code HCGEMRTV15
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC15
Metering module and meters
HCGEMRCO15
201
SYSTEM COMPONENTS
SINGLE SUPPLY
Heat distribution and metering modules “GEMINI” GEMINI C15-2A DZ SR MT SINGLE SUPPLY Description
Code HCGEMRTV12
Gemini C15-2A DZ SR MT
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC12
Metering module and meters
HCGEMRCO12
GEMINI C15-2A DZ MT SINGLE SUPPLY Description
Code HCGEMRTV16
Gemini C15-2A DZ MT
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC16
Metering module and meters
HCGEMRCO16
GEMINI C25-2A SR MT SINGLE SUPPLY Description
Code HCGEMRTV13
Gemini C25-2A DZ SR MT
TWO SEPARATE SUPPLIES Description
Code
Metal case and spacers
HCGEMRDC13
Metering module and meters
HCGEMRCO13
GEMINI C25-2A DZ MT SINGLE SUPPLY Description
Code HCGEMRTV17
Gemini C25-2A DZ MT
TWO SEPARATE SUPPLIES Description
WARM COMFORT
Code
Metal case and spacers
HCGEMRDC17
Metering module and meters
HCGEMRCO17
202
Articolo
Description
Code
Metal case for encased installation single zone system (450 x 600 x 110)
HCGEMCAS00
Metal case for encased installation two-zone system (800 x 600 x 110)
HCGEMCAS01
DOMESTIC HOT WATER METER WITH COCKS AND ANTI-THEFT SPACER Max temperature 90 °C, Pn 16, Qmax. 1.5 m3/h
HCGEMKACS0
domestic cold water meter with cocks and anti-theft spacer Max temperature 30 °C, Pn 16, Qmax. 1.5 m3/h
HCGEMKAFS0
low-temperature unit
HCGEMKBT00
ENERGY METER 1.5 m3/h WITH TEMPERATURE PROBES AND ANTI-THEFT SPACER FOR COOLING AND HEATING SYSTEMS, Pn 16, Max temperature 130 °C
HCGEMKCON0
ENERGY METER 2.5 m3/h WITH TEMPERATURE PROBES AND ANTI-THEFT SPACER FOR COOLING AND HEATING SYSTEMS, Pn 16, Max temperature 130 °C
HCGEMKCON1
dhw thermostatic mixing valve
HCGEMKMT00
203
SYSTEM COMPONENTS
ACCESSORIES
Heat distribution and metering modules “GEMINI” Articolo
WARM COMFORT
Description
Code
insulation for metering module for models: GEMINI C15-2A; GEMINI C25-2A; GEMINI C15-2A MT; GEMINI C25-2A MT
HCGEMKIS00
insulAting unit for metering modules for different heating zones for models: GEMINI C15-2A DZ SR; GEMINI C15-2A DZ; GEMINI C25-2A DZ SR; GEMINI C25-2A DZ; GEMINI C15-2A DZ SR MT; GEMINI C15-2A DZ MT; GEMINI C25-2A DZ SR MT; GEMINI C25-2A DZ MT
HCGEMKIS01
insulation for low-temperature unit
HCGEMKIS02
insulation for domestic hot and cold water meters
HCGEMKIS03
204
ACCESSORIES
Installation example
KEY MI1 RI1 MI2 RI2 ACS AFS MB RB FLOW MANDATA
System 1 flow System 1 return System 2 flow System 2 return DHW Domestic cold water Water heater flow Water heater return
CENTRALE TERMICA THERMAL POWER PLANT
RETURN RITORNO ACS MANDATA FLOW RITORNO RETURN AFS
AFS DOMESTIC COLD WATER ACS DOMESTIC HOT WATER
205
Heat distribution and metering modules “GEMINI” Flow meter Class
Pn (bar)
DN (mm)
Qmin (m3/h)
Qn (m3/h)
Qmax (m3/h)
Tmax (°C)
Capacity meter
Code
Gemini Central 15 - 50
B
16
50
0,6
15
30
130
Woltmann
HCGEMCWT05
Gemini Central 25 - 65
B
16
65
1
25
50
130
Woltmann
HCGEMCWT01
Gemini Central 40 - 80
B
16
80
1,6
40
80
130
Woltmann
HCGEMCWT02
Gemini Central 60 - 100
B
16
100
2,4
60
120
130
Woltmann
HCGEMCWT03
Gemini Central 100 - 125
B
16
125
4
100
200
130
Woltmann
HCGEMCWT04
Description
ENERGY METER Description
Code
HCGEMCNT00
Gemini Central Meter
ENERGY METER PROBES Description
Code
Gemini probes 85 including wells (2 probes and 2 wells)
HCGEMSN850
Gemini probes 42 (2 probes)
HCGEMSN450
Gemini well 45 (1 well)
HCGEMPZ450
IMPULSE METER Description
Code
Impulse Meter
HCGEMCTI00
To be installed between the data concentrator and the third non-drinking water meter.
UTILITY 3
UTILITY n
UTILITY 1
UTILITY 2
KEY MI1 RI1 MI2 RI2 ACS AFS MB RB
WARM COMFORT
206
System 1 flow System 1 return System 2 flow System 2 return DHW Domestic cold water Water heater flow Water heater return
CONSUMPTION DATA READING GEMINI data Consumption data can be read in two different ways: • Local reading using the GEMINI METER display: used when the meter can be reached easily and when the apartment block ise not particularly large. • Centralisation by means of M-BUS: in this case, depending on the numbers of users, a data acquirer for local or remote reading of consumption and operation data of each individual meter using a PC or standard modem is chosen. With the data acquirer, GEMINI SOFTWARE must be purchased, allowing the apartment block manager to carry out a complete reading of the BUS system, viewing energy consumption, instantaneous flow rates, ΔT, errors. due to tampering. di manomissione.
Gemini Data 20
HCGEMCON00
Gemini Data 60
HCGEMCON01
Gemini Data 120
HCGEMCON02
Gemini Data 250
HCGEMCON03
Thermal power plant
administrator
207
ACCESSORIES
Code
Description
GEMINI ENCASED ZONE MODULES ENCASED ZONE MODULES The distribution modules are used to manage several heating zones on properties and they can be connected both to traditional and condensing boilers. Zones can be high or low temperature.
GEMINI 3A Wall-hung encased zone module managing three direct areas, including: • collector/hydraulic separator, • electronic board for zone management, • outdoor probe for “sliding temperature” function, • RAL 9010 white painted steel sheet case for encased installation, • three direct circulation units with circulation pump and non-return valve mounted on the return pipe, • connections diameter ¾” F. 595
6
360
D
690
∆P (m H2O)
5
58,8
TS
49,0
4
39,2
3
29,4
2
19,6
∆P (kPa)
190
1
9,8
0
0 2200
0
200
400
600
1000 1200 1400 1600 1800 2000
800
portata/flow flow rate (l/h) (l/h)
ZONA 1
D unità diretta (alta temperatura) D unità directmiscelata zone (high-temperature) TS a temp. scorrevole
ZONA ZONA 2 3
TS mixed zone with sliding temperature mode
Description
Code
Gemini 3A
0KITZONE04
GEMINI 2 AB Wall-hung encased zone module with a direct area and a mixed area, including: • collector/hydraulic separator, • electronic board for zone management, • outdoor probe for “sliding temperature” function, • RAL 9010 white painted steel sheet case for encased installation, • direct circulation unit with circulation pump and non-return valve mounted on the return pipe, • sliding temperature mixing unit with three way mixer valve and rotating electric servo control, circulation pump, non-return valve mounted on the return pipe, • connections diameter ¾”.
190
595
D
∆P (m H2O)
5
WARM COMFORT
49,0
4
39,2
3
29,4
2
19,6 9,8
1 0
690 ZONA 1
58,8
TS
0
200
400
600
800
1000 1200 1400 1600 1800 2000 portata/flow (l/h) flow rate (l/h)
0 2200
D unità diretta (alta temperatura) D direct zone (high-temperature) TS unità miscelata a temp. scorrevole
ZONA 2
∆P (kPa)
6
360
TS mixed zone with sliding temperature mode
Description
Code
Gemini 2 AB
0KITZONE03
208
UNDER-BOILER ZONE MODULES GEMINI 2 ABS Under-boiler zone module with a direct area and a mixed area, including: • hydraulic separator, • electronic board for zone management, • outdoor probe for “sliding temperature” function, • direct circulation unit with circulation pump and non-return valve mounted on the return pipe, • sliding temperature mixing unit with three way mixer valve and rotating electric servo control, circulation pump, non-return valve mounted on the return pipe, • steel sheet cover fixed on the boiler casing and to the wall • connections diameter ¾”.
450
3/4”
6
D
400
∆P (m H2O)
5
3/4” 3/4”
4
39,2
3
29,4
2
19,6
1
9,8
0
0 2200
0
200
400
300
3/4”
49,0
600
800
1000 1200 1400 1600 1800 2000 portata/flow flow rate (l/h)(l/h)
D unità diretta (alta temperatura) TSDunità miscelata a temp. scorrevole direct zone (high-temperature)
TS mixed zone with sliding temperature mode Cover steel sheet dimensions A-A 300 A
395
3/4”
58,8
TS
87° A 450 VISTA FRONTALE
FRONT VIEW
∆P (kPa)
3/4”
ACCESSORIES
It can be installed on boilers: • Tahiti Dual Line, • Tahiti Condensing Line Tech.
270 VISTA LATERALE SEZIONATA
LATERAL VIEW (SECTION)
Description
Code
Gemini 2 ABS
0KITZONE02
209
THERMOREGULATION SYSTEMS thermoregulating units Articolo
Code
Remote control for thermoregulation control unit (temperature regulation)
0CREMOTO00
Remote control for thermoregulation control unit (all functions)
0CREMOTO01
Remote Control
0CREMOTO04
300B day/week room programmable chronothermostat
0CROAMSE00
Day timer kit
0KITBEST04
Articolo
25 35
30
5
10 15
25
20
Description
Week timer kit
Thermoregulation control unit kit
Climatic control unit kit for two-stage burner
Temperature probe for climatic control unit and control panels (KF/SPF)
20
15
WARM COMFORT
Description
lectromechanical room thermostat
210
Code
0KITBEST05
0KITCEEL02
0KITCEEL04
0SONDASO00
0TERAMEL00