Fire Safety Management - Fire Design Solutions Ltd

0 downloads 200 Views 2MB Size Report
systems, AOV (automatic opening vents), door mag locks, emergency lift control, fireman's override switches, fire and sm
360

Fire Safety Management

‘FireSmart’ is an addressable, intelligent control system with the ability to integrate several fire safety systems into a single control FireSmart makes the management of fire

All the electronic components are tested and

systems for large scale residential and

compliant to British Standard BS 5839, giving you

commercial properties simple. It provides the

peace of mind and a system you can trust. By

ultimate notification and operation of essential

designing to this industry standard and ensuring

life safety systems in both ‘normal’ and ‘fire’

that all components are open protocol, FireSmart

modes; it can monitor all fire safety systems

allows for ‘off the shelf’ availability from numerous

and produce status reports and commissioning

sources. Unlike traditional closed protocol fire

logs – ideal for building and facilities managers.

safety management systems that ensure the installing company is tied in for the life of the

Designed in response to client requirements for

system, FireSmart can be maintained and

enhanced, intelligent monitoring of all fire safety

modified by any qualified fire alarm engineer.

systems, FireSmart is truly open protocol – with components and programming supplied by

FireSmart’s components are connected via a

established and respected third party companies

4-core fire resistant cable which links all of the

to produce a ‘best in class’ product.

devices. Additional components can be added in the future and the programming can be modified, if needed, by any fire alarm commissioning engineer.

Features Overview • • • •

Intelligent true open protocol system One 4-core cable links all devices Easy to install, program and operate Large graphic display with 8 lines of 40 character graphics • 16 zone LED indicators • Powerful and versatile cause and effect programming wizard including: cause and effect action, displacement configuration and test mode configuration • Manage up to 512 programmable I/O within a single system

(For illustrative purposes only)

• • • • • • • • • •

3A power supply Real time clock Panel can be networked Supports Apollo, Argus, Vega and Hochiki protocols Compatible with Focus and View repeaters Stores up to 500 events in events log Dial up modem connection available Certified to EN54-2 and EN54-4 Front loading printer option available Programmable one touch test mode

Building-wide fire safety management FireSmart is true open protocol, using off the shelf

immediately reporting any faults found via its

instructions. These controls can be easily

Kentec fire alarm programming via an RS232 link.

LCD display. Should fire fighters need to attend

accessed using a standard FB1 key. Compliant to

The panel incorporates an uninterrupted power

an incident, the override key issue is solved as

British Standard BS 5839, the system allows up to

supply with batteries and requires an external

the system was designed using feedback from

127 fire safety devices to be integrated on a loop

230v single phase 50 hertz electrical power supply

experienced fire fighters - all fan and damper

and managed by a single control panel – providing

– similar to that used by a fire alarm panel.

controls and firefighter switches are placed inside

a complete fire safety system in a single product.

The system constantly monitors all components;

the alarmed enclosure complete with clear usage

Flexibility In order to be as adaptable as possible to a wide variety of applications FireSmart can be expanded from one to two loops.

Once installed, FireSmart constantly monitors and reports on all fire safety systems, ensuring any issues that may occur can be swiftly dealt with. It is also able to facilitate and interface between a number of other systems such as sprinkler systems and door entry systems.

For more exacting levels of control, users can adjust the sensitivity of the detection system to allow for drift compensation to ensure that each building is monitored accurately and allows for idiosyncrasies in the immediate area of detection equipment.

Simple Installation The Fire Smart system connects to Interface I/O

Where maglocks or smoke curtains are

Boxes (IOB) via a fire rated 4-core cable that

connected to the system, a local 13 amp single

runs around the building allowing the necessary

phase fuse spur is located adjacent to one of

communications. The panel incorporates all the

the IOB boxes. In the case of smoke extract

power necessary with no additional fuse spur

fans or car park extract fans, an IOB is located

requirements for dampers, actuators, smoke

adjacent to the fan panel allowing the system to

detectors, stair vents, etc.

be operated and information from the fan panel such as duty fan running or standby fan to be repeated on the Fire Smart panel.

Greenwich Reach, London SMOKE EXTRACT / ENVIRONMENTAL FAN

FAN PANE

SMOKE VENTILATOR

4 CORE L5 FIRESMART LOOP

CHQR TO 3RD PARTY CONTROLS

CHQR CAR PARK INDUCTION / IMPULSE FAN

DOOR ACCESS CONTROL LOCK

SMOKE BREAK GLASS

RESIDENTIAL SPRINKLER FLOW SWITCH SOUNDER

SMOKE DETECTOR

2 CORE L1-L4 FIRESMART LOOP WINDOW / DOOR ACTUATOR

MAG-LOCK DOOR RETAINER

ENIVIRONMENTAL / SMOKE VCD DAMPER

SMOKE DETECTOR Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

Lorem ipsum

1

Lorem ipsum

SMOKE DOOR DAMPER

Lorem ipsum

Lorem ipsum

2

3

Lorem ipsum

4

5

6

Lorem ipsum

7

8

9

Lorem ipsum

10

11

12

13

Lorem ipsum

14

15

Lorem

Lorem

Lorem

Lorem

16

FIREMAN KEY SWITCH

CKS AG LO M R TOMATIC OPENING VEN DOO AOV (AU T)

CO RR ID

SMOKE MAN AGE ME NT

M SYSTE LER INK SPR

DOO R EN TRY AN DA CC ES S

OL TR

TEM SYS GE AN CH AIR OR

CO N

FIRE AND SMOKE CURTAINS

SMOKE VENTILATI ON S

S TEM YS SOUNDERS

ER MP DA

C

ON TR OL

RO OF AND STA IR

VENT CONTRO L

S CHE WIT S E D VERRI FIREMANS O

360o Fire Protection In a single, open protocol, life safety control system, FireSmart manages and monitors smoke detection, sounders, smoke ventilation systems, corridor air change systems, AOV (automatic opening vents), door mag locks, emergency lift control, fireman’s override switches, fire and smoke curtains, sprinkler systems, damper control, roof and stair vent control and access door control.

standards that are far from standard

Fire Design Solutions Ltd 152 |154 London Road Greenhithe Kent DA9 9JW United Kingdom T +44 (0)1322 387 411 F +44 (0)1322 386 361 [email protected] www.firedesignsolutions.com

ISO 9001 : 2008 FS549035

Registered Office: Fire Design Solutions Ltd. The House, High Street, Brenchley, Kent, TN12 7NQ. Registered No: 04460351