systems, AOV (automatic opening vents), door mag locks, emergency lift control, fireman's override switches, fire and sm
360
Fire Safety Management
‘FireSmart’ is an addressable, intelligent control system with the ability to integrate several fire safety systems into a single control FireSmart makes the management of fire
All the electronic components are tested and
systems for large scale residential and
compliant to British Standard BS 5839, giving you
commercial properties simple. It provides the
peace of mind and a system you can trust. By
ultimate notification and operation of essential
designing to this industry standard and ensuring
life safety systems in both ‘normal’ and ‘fire’
that all components are open protocol, FireSmart
modes; it can monitor all fire safety systems
allows for ‘off the shelf’ availability from numerous
and produce status reports and commissioning
sources. Unlike traditional closed protocol fire
logs – ideal for building and facilities managers.
safety management systems that ensure the installing company is tied in for the life of the
Designed in response to client requirements for
system, FireSmart can be maintained and
enhanced, intelligent monitoring of all fire safety
modified by any qualified fire alarm engineer.
systems, FireSmart is truly open protocol – with components and programming supplied by
FireSmart’s components are connected via a
established and respected third party companies
4-core fire resistant cable which links all of the
to produce a ‘best in class’ product.
devices. Additional components can be added in the future and the programming can be modified, if needed, by any fire alarm commissioning engineer.
Features Overview • • • •
Intelligent true open protocol system One 4-core cable links all devices Easy to install, program and operate Large graphic display with 8 lines of 40 character graphics • 16 zone LED indicators • Powerful and versatile cause and effect programming wizard including: cause and effect action, displacement configuration and test mode configuration • Manage up to 512 programmable I/O within a single system
(For illustrative purposes only)
• • • • • • • • • •
3A power supply Real time clock Panel can be networked Supports Apollo, Argus, Vega and Hochiki protocols Compatible with Focus and View repeaters Stores up to 500 events in events log Dial up modem connection available Certified to EN54-2 and EN54-4 Front loading printer option available Programmable one touch test mode
Building-wide fire safety management FireSmart is true open protocol, using off the shelf
immediately reporting any faults found via its
instructions. These controls can be easily
Kentec fire alarm programming via an RS232 link.
LCD display. Should fire fighters need to attend
accessed using a standard FB1 key. Compliant to
The panel incorporates an uninterrupted power
an incident, the override key issue is solved as
British Standard BS 5839, the system allows up to
supply with batteries and requires an external
the system was designed using feedback from
127 fire safety devices to be integrated on a loop
230v single phase 50 hertz electrical power supply
experienced fire fighters - all fan and damper
and managed by a single control panel – providing
– similar to that used by a fire alarm panel.
controls and firefighter switches are placed inside
a complete fire safety system in a single product.
The system constantly monitors all components;
the alarmed enclosure complete with clear usage
Flexibility In order to be as adaptable as possible to a wide variety of applications FireSmart can be expanded from one to two loops.
Once installed, FireSmart constantly monitors and reports on all fire safety systems, ensuring any issues that may occur can be swiftly dealt with. It is also able to facilitate and interface between a number of other systems such as sprinkler systems and door entry systems.
For more exacting levels of control, users can adjust the sensitivity of the detection system to allow for drift compensation to ensure that each building is monitored accurately and allows for idiosyncrasies in the immediate area of detection equipment.
Simple Installation The Fire Smart system connects to Interface I/O
Where maglocks or smoke curtains are
Boxes (IOB) via a fire rated 4-core cable that
connected to the system, a local 13 amp single
runs around the building allowing the necessary
phase fuse spur is located adjacent to one of
communications. The panel incorporates all the
the IOB boxes. In the case of smoke extract
power necessary with no additional fuse spur
fans or car park extract fans, an IOB is located
requirements for dampers, actuators, smoke
adjacent to the fan panel allowing the system to
detectors, stair vents, etc.
be operated and information from the fan panel such as duty fan running or standby fan to be repeated on the Fire Smart panel.
Greenwich Reach, London SMOKE EXTRACT / ENVIRONMENTAL FAN
FAN PANE
SMOKE VENTILATOR
4 CORE L5 FIRESMART LOOP
CHQR TO 3RD PARTY CONTROLS
CHQR CAR PARK INDUCTION / IMPULSE FAN
DOOR ACCESS CONTROL LOCK
SMOKE BREAK GLASS
RESIDENTIAL SPRINKLER FLOW SWITCH SOUNDER
SMOKE DETECTOR
2 CORE L1-L4 FIRESMART LOOP WINDOW / DOOR ACTUATOR
MAG-LOCK DOOR RETAINER
ENIVIRONMENTAL / SMOKE VCD DAMPER
SMOKE DETECTOR Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
Lorem ipsum
1
Lorem ipsum
SMOKE DOOR DAMPER
Lorem ipsum
Lorem ipsum
2
3
Lorem ipsum
4
5
6
Lorem ipsum
7
8
9
Lorem ipsum
10
11
12
13
Lorem ipsum
14
15
Lorem
Lorem
Lorem
Lorem
16
FIREMAN KEY SWITCH
CKS AG LO M R TOMATIC OPENING VEN DOO AOV (AU T)
CO RR ID
SMOKE MAN AGE ME NT
M SYSTE LER INK SPR
DOO R EN TRY AN DA CC ES S
OL TR
TEM SYS GE AN CH AIR OR
CO N
FIRE AND SMOKE CURTAINS
SMOKE VENTILATI ON S
S TEM YS SOUNDERS
ER MP DA
C
ON TR OL
RO OF AND STA IR
VENT CONTRO L
S CHE WIT S E D VERRI FIREMANS O
360o Fire Protection In a single, open protocol, life safety control system, FireSmart manages and monitors smoke detection, sounders, smoke ventilation systems, corridor air change systems, AOV (automatic opening vents), door mag locks, emergency lift control, fireman’s override switches, fire and smoke curtains, sprinkler systems, damper control, roof and stair vent control and access door control.
standards that are far from standard
Fire Design Solutions Ltd 152 |154 London Road Greenhithe Kent DA9 9JW United Kingdom T +44 (0)1322 387 411 F +44 (0)1322 386 361
[email protected] www.firedesignsolutions.com
ISO 9001 : 2008 FS549035
Registered Office: Fire Design Solutions Ltd. The House, High Street, Brenchley, Kent, TN12 7NQ. Registered No: 04460351