FW-43XD8001 (built-in jack input) FW-49XD8001 (built-in jack input) FW-55XD8501 (built-in jack input) FW-65XD8501 (built-in jack input) FW-75XD8501 (built-in jack input) FW-85XD8501 (built-in jack input) FWD-100ZD9501 (CBX-H11/1 required)
Professional BRAVIA RS232C control
3
Prerequisites Step 1 Use latest firmware available (at least V. 3.395 for built-in models) Download links
Professional BRAVIA RS232C control
4
CBX-H11 models Setup configuration: 1) Go to Hotel / Pro mode (“ i+ / mute / vol+ / on” with the remote control, done on standby mode) 2) Go to Settings > ECO •
Select Idle TV standby to “off”
3) Go to Settings > Hotel Pro Mode •
Select IP Control
•
Set Authentication to “Normal & Pre-shared Key”
•
Set Simple IP control to “On”
4) Activate Hotel / Pro Mode
Test: 1) Connect the CBX-H11 to the control device:
2) Use the SerialCommandChecker.exe tool in the support directory: -
Set product type display to “ Display”
-
Set com port number
-
Use pud protocol master XLS file and copy/past command to be tested from RS232 tab Examples: power on 8C 00 00 02 01 8F / power off 8C 00 00 02 00 8E
Professional BRAVIA RS232C control
5
Built-in input models Setup configuration: 1) Go to Hotel / Pro mode (“ i+ / mute / vol+ / home” with the remote control, done in running state) 2) Go to Settings > System Settings > ECO •
Select Idle TV standby to “off”
3) Go to Settings > Network > Home Network Setup •
Select IP Control
•
Set Authentication to “Normal & Pre-shared Key”
•
Set Simple IP control to “On”
4) Go to Hotel Professional Mode settings •
Select RS232 control mode “via serial port”
5) Activate Hotel / Pro Mode After complete restart of the unit, please AC off the unit 5 second and then AC on. After complete restart this feature will enable to be used.
Tests and tools: 1) Connect the RS232C pc to the Professional BRAVIA, using following pinning:
2) Use the SerialCommandChecker.exe tool in the support directory: -
Set product type display to “ Display”
-
Set com port number
-
Use pud protocol master XLS file and copy/past command to be tested from RS232 tab Examples: power on 8C 00 00 02 01 8F / power off 8C 00 00 02 00 8E