1 AIR CONDITIONING COMPRESSORS C O N T E N T S Product Description ..... 2
AIR CONDITIONING COMPRESSORS
C O N T E N T S
Product Description .......................................................................................... 2 Features & Performance Story .................................................................. 3 Performance Nominals - 50 Hz - CK3 & CR6 Series ............................................................................................... 5 Performance Nominals - 60 Hz - CK3 Series ................................................................................................ 7 Mechanical Specifications .......................................................................... 8 Electrical Components for Single phase compressors ............................ 9 Electrical Specifications ........................................................................... 10 Full range Compressor for air conditioning Single phase & Three phase compressor ............................................... 11 Dimensional Drawings ............................................................................. 13 50Hertz Performance Data ....................................................................... 19 60Hertz Performance Data ....................................................................... 31 CR6 & CK3 series compressor Nomenclature ........................................ 33 KC series compressor Nomenclature ..................................................... 34
1
cymk
PRODUCT DESCRIPTION No matter how diverse the demands of air conditioning application around the world may be, they share a common need: quietest & continues - operation. That’s why Kirloskar Copeland’s engineering &
Manufacturing Plant
manufacturing teams have stretched the boundaries of compressor design & production to create the quietest, most reliable full range reciprocating compressor, available today. Taming down the Middle East heat wave is the best test any compressor can take. Which is why, the Kirloskar Copeland’s compressors are performing with fail- safe reliability in Middle east, Asian, African &
Shop floor
European markets. So you can be sure that when you are installing the Kirloskar Copeland compressor, you are sharing the world’s coolest secret.
Compressor Welding
2
Compressor Assembly
FEATURES
PERFORMANCE STORY
High Efficiency
Enhanced Technology: Built on proven
Quietest Operation
success of Kirloskar Copeland’s various
Low Sound & Discharge Pulse
design platforms. The air conditioning compressor series has been optimized for
Single & Three Phase Models Available
the
Internal Muffler & Suspension
reciprocating technology will meet the
Wide Voltage Range
next
decade.
This
advanced
demands of all worldwide markets well into the future.
Internal Motor Protection Moulded Plug Terminal Connector Option Tropicalized Internal Pressure Relief Valve Convenient Arrangement of Fittings, Terminal Area, & Mounting Feet
Lower Sound, Superior Reliability: The air conditioning
compressor
series
is
engineered for lower compressor sound & a reduced discharge pulse to decrease the system sound & vibration. It also offers industry -leading levels of reliability, especially at higher ambient temperatures, a critical factor in warmer global climates.
Exceptional Value & Flexibility:Kirloskar Copeland has designed its new compressor for easy system drop - in for upgrades or replacements. Customers have the option to specify preferred features, such as optional molded plug, mountings those reduces assembly time. The result is greater flexibility & the value you except from Kirloskar Copeland.
3
cymk
4
CK3 & CR6 SERIES
PERFORMANCE NOMINALS
50 HERTZ SINGLE PHASE
R22
230 - 1 - 50 (PF1), 220-1-50 (PFZ) TEST VOLTAGE CAPACITY
MODELS
ENERGY EFFICIENCY RATING
RATING CONDITION
BTU/ HOUR
KCAL/ HOUR
WATTS
MOTOR WATTS
AMPERES
BTU/H MOTOR WATTS
KCAL/H MOTOR WATTS
WATTS/ MOTOR WATTS
CK22K3-PF1
A B
18340 17875
4622 4505
5375 5239
1925 1925
8.8 8.8
9.5 9.3
2.4 2.3
2.8 2.7
CK24K3-PFZ
A B
20350 19800
5128 4990
5964 5803
2100 2100
9.7 9.7
9.7 9.4
2.4 2.4
2.8 2.8
CK30K3-PFZ
A B
25150 24500
6338 6172
7371 7180
2725 2725
12 12
9.2 9.0
2.3 2.3
2.7 2.6
CK32K3-PFZ
A B
27200 26500
6854 6678
7972 7766
2950 2950
14 14
9.2 9.0
2.3 2.3
2.7 2.6
CR22K6M-PF1
A B
19000 18500
4788 4662
5568 5422
1750 1750
7.8 7.8
10.9 10.6
2.7 2.7
3.2 3.1
CR30K6M-PF1
A B
25000 24250
6300 6111
7327 7107
2350 2350
11 11
10.6 10.3
2.7 2.6
3.1 3.0
CR36K6-PFZ
A B
30100 29300
7585 7383
8821 8587
2720 2720
13.6 13.6
11.1 10.8
2.8 2.7
3.2 3.2
CR42K6-PFZ
A B
36100 35200
9097 8870
10580 10316
3240 3240
15.4 15.4
11.1 10.9
2.8 2.7
3.3 3.2
PERFORMANCE NOMINALS
50 HERTZ THREE PHASE
R22
400 - 3 - 50 TEST VOLTAGE CAPACITY
MODELS
RATING BTU/ CONDITION HOUR
ENERGY EFFICIENCY RATING
KCAL/ HOUR
WATTS
MOTOR AMPERES BTU/H KCAL/H WATTS/ WATTS MOTOR WATTS MOTOR WATTS MOTOR WATTS
CR22K6M-TFM*
A B
18250 17700
4599 4460
5349 5187
1800 1800
3.1 3.1
10.1 9.8
2.5 2.4
2.9 2.8
CR30K6M-TFM*
A B
25000 24250
6300 6110
7327 7107
2350 2350
4.3 4.3
10.6 10.3
2.7 2.6
3.1 3.0
CR36K6-TF5
A B
29900 29100
7535 7335
8763 8528
2680 2680
4.9 4.9
11.2 10.9
2.8 2.7
3.3 3.2
CR42K6-TF5 CR42K6-TFM
A B
35100 34200
8845 8618
10287 10023
3300 3300
6.1 6.1
10.6 10.4
2.7 2.6
3.1 3.0
* Under Development. RATING CONDITION
RATING STANDARD
EVAPORATING TEMPERATURE °F/°C
CONDENSING TEMPERATURE °F/°C
AMBIENT TEMPERATURE °F/°C
LIQUID TEMPERATURE °F/°C
RETURN GAS TEMPERATURE °F/°C
A
ASRE/T
45 7.2
130 54.4
95 35
115 46.1
95 35
B
ARI
45 7.2
130 54.4
95 35
115 46.1
65 18.3
5
KC SERIES
PERFORMANCE NOMINALS
50 HERTZ SINGLE PHASE
R22
230 - 1 - 50 TEST VOLTAGE CAPACITY
MODELS
ENERGY EFFICIENCY RATING
RATING CONDITION
BTU/ HOUR
KCAL/ HOUR
WATTS
MOTOR WATTS
AMPERES
BTU/H MOTOR WATTS
KCAL/H MOTOR WATTS
WATTS/ MOTOR WATTS
KCJ 511 HAE
A B
9350 9100
2356 2293
2740 2667
1020 1020
4.7 4.7
9.2 8.9
2.3 2.2
2.7 2.6
KCJ 515 HAE
A B
12800 12470
3225 3141
3751 3655
1420 1420
6.4 6.4
9.0 8.8
2.3 2.2
2.6 2.5
KCH 522 HAE
A B
18340 17850
4620 4497
5375 5231
2000 2000
9.1 9.1
9.2 8.9
2.3 2.2
2.7 2.6
KCA 522 HAE*
A B
18500 —
4662 —
5417 —
1880 —
8.6 —
9.8 —
2.5 —
2.9 —
KCH 523 HAE
A B
19200 18800
4838 4737
5627 5510
1780 1780
8.2 8.2
10.8 10.6
2.7 2.7
3.2 3.1
KCH 524 HAE
A B
20000 19500
5040 4914
5861 5715
2290 2290
10 10
8.7 8.5
2.2 2.1
2.6 2.5
KCH 528 HAE
A B
24000 23300
6048 5872
7034 6829
2800 2800
13.6 13.6
8.6 8.3
2.2 2.1
2.5 2.4
PERFORMANCE NOMINALS
50 HERTZ THREE PHASE
R22
400 - 3 - 50 TEST VOLTAGE CAPACITY
MODELS
RATING BTU/ CONDITION H O U R
KCAL/ HOUR
WATTS
MOTOR AMPERES BTU/H KCAL/H WATTS/ WATTS MOTOR WATTS MOTOR WATTS MOTOR WATTS
KCH 522 HAE
A B
18340 17850
4620 4497
5375 5231
1850 1850
3 3
9.9 9.7
2.5 2.4
2.9 2.8
KCH 528 HAE
A B
24000 23300
6048 5872
7034 6829
2500 2500
4 4
9.6 9.3
2.4 2.3
2.8 2.7
KCG 554 HAE
A B
45000 43875
11340 11057
13188 12858
4450 4450
7.2 7.2
10.1 9.9
2.6 2.5
3.0 2.9
KCG 562 HAE
A B
52000 50700
13100 12775
15240 14859
5250 5250
8.5 8.5
9.9 9.7
2.5 2.4
2.9 2.8
KCG 572 HAE
A B
60000 58320
15120 14697
17584 17092
6100 6100
10.2 10.2
9.8 9.6
2.5 2.4
2.9 2.8
RATING CONDITION
RATING STANDARD
EVAPORATING TEMPERATURE °F/°C
CONDENSING TEMPERATURE °F/°C
AMBIENT TEMPERATURE °F/°C
LIQUID TEMPERATURE °F/°C
RETURN GAS TEMPERATURE °F/°C
A
ASRE/T
45 7.2
130 54.4
95 35
115 46.1
95 35
B
ARI
45 7.2
130 54.4
95 35
115 46.1
65 18.3
* Under Development. 6
ENERGY EFFICIENCY RATING
CK3 SERIES
PERFORMANCE NOMINALS
60 HERTZ SINGLE PHASE
R22
230 -1-60 TEST VOLTAGE CAPACITY
MODELS
ENERGY EFFICIENCY RATING
RATING CONDITION
BTU/ HOUR
KCAL/ HOUR
WATTS
MOTOR WATTS
AMPERES
BTU/H MOTOR WATTS
KCAL/H MOTOR WATTS
WATTS/ MOTOR WATTS
CK20K3-PFV
A B
– 20000
– 5040
– 5861
– 2140
– 9.6
– 9.4
– 2.4
– 2.7
CK24K3-PFV
A B
– 23500
– 5922
– 6887
– 2500
– 11
– 9.4
– 2.4
– 2.8
CK27K3-PFV
A B
– 26500
– 6678
– 7766
– 2900
– 12.9
– 9.1
– 2.3
– 2.7
CK30K3-PFV*
A B
– 29500
– 7434
– 8646
– 3225
– 14.5
– 9.1
– 2.3
– 2.7
* Under development
RATING CONDITION
RATING STANDARD
EVAPORATING TEMPERATURE °F/°C
CONDENSING TEMPERATURE °F/°C
AMBIENT TEMPERATURE °F/°C
LIQUID TEMPERATURE °F/°C
RETURN GAS TEMPERATURE °F/°C
A
ASRE/T
45 7.2
130 54.4
95 35
115 46.1
95 35
B
ARI
45 7.2
130 54.4
95 35
115 46.1
65 18.3
Compress Cooling : KCJ Series - Fan, 350 CFM KCH , CR6, CK3 Series - Fan, 400 CFM KCG Series - Fan, 420 CFM
7
AIR CONDITIONING COMPRESSORS R22 MECHANICAL SPECIFICATIONS MODEL
IN3 CM 3 CUBIC INCHES PER REVOLUTION CUBIC CENTIMETERS PER REVOLUTION
CFH M3 /HR CUBIC FEET PER HOUR CUBIC METERS PER HOUR
COMPRESSOR NET WEIGHT KILOGRAMS POUNDS
50 HERTZ 2900 RPM
CK20K3-PFV
2.36 1.76
2.399 39.32
241.62 6.84
28 61.6
CK22K3-PF1
2.12 1.58
2.490 40.8
250.71 7.10
28 61.6
CK24K3-PFV
2.68 2.00
2.701 44.26
271.97 7.70
28 61.6
CK24K3-PFZ
2.36 1.76
2.701 44.26
271.97 7.70
28 61.6
CK27K3-PFV
3.22 2.40
3.028 49.62
304.89 8.63
28 61.6
CK30K3-PFV
3.50 2.61
3.254 53.32
327.64 9.28
29 63.93
CK30K3-PFZ
3.22 2.40
3.254 53.32
327.64 9.28
28 61.6
CK32K3-PFZ
3.19 2.38
3.521 57.70
354.31 10.03
28 61.6
CR22K6M-PF1
1.88 1.40
2.490 40.8
250.71 7.10
29.8 65.6
CR22K6M-TFM *
2.05 1.53
2.490 40.8
250.71 7.10
— —
CR30K6M-PF1
2.63 1.96
3.140 51.45
316.15 8.95
33.4 73.63
CR30K6M-TFM *
2.76 2.06
3.140 51.45
316.15 8.95
30.0 66.1
CR36K6-PFZ
3.06 2.28
3.640 59.65
366.54 10.38
34.9 76.9
CR36K6-TF5
3.15 2.35
3.640 59.65
366.54 10.38
31 68.3
CR42K6-PFZ
3.67 2.74
4.399 72.08
442.98 12.54
34.9 76.9
CR42K6-TF5
3.89 2.90
4.399 72.09
442.98 12.54
32.7 72.1
KCJ 511 HAE
1.07 0.80
1.114 18.27
112.18 3.18
21.5 47.3
KCJ 515 HAE
1.54 1.15
1.581 25.92
159.78 4.52
22.6 49.82
KCH 522 HAE
2.14 1.60
2.430 39.82
244.69 6.93
31.3 66.6
KCA 522 HAE *
2.01 1.50
2.430 39.82
244.69 6.93
29 63.93
KCH 523 HAE
2.01 1.50
2.430 39.82
244.69 6.93
31.3 68.9
KCH 524 HAE
2.14 1.60
2.620 42.93
263.82 7.47
30.3 66.6
KCH 528 HAE
2.95 2.20
3.230 52.93
325.24 9.21
32.3 71.06
KCG 554 HAE
5.23 3.90
6.04 99.96
608.19 17.22
50.1 110.22
KCG 562 HAE
6.17 4.60
7.180 117.66
723.00 20.48
50.7 111.54
KCG 572 HAE
7.24 5.40
8.129 133.22
818.55 23.18
51.4 113.32
* Under development.
8
NOMINAL HP KW
AIR CONDITIONING COMPRESSORS R22 ELECTRICAL COMPONENTS FOR AIR CONDITIONING SINGLE PHASE COMPRESSORS MODEL
MOTOR CIRCUIT
RUN CAPACITOR UF
START CAPACITOR
START RELAY
UF
CK20K3-PFV
PSC / CSCR
25 / 370 VAC
120/150 *
3ARR3CT6W5 or AC85007* or RVA3AI3D
CK22K3-PF1
PSC / CSCR
36
120/150 *
AC85007* or RVA3AI3D
CK24K3-PFV
PSC / CSCR
35 / 370 VAC
120/150 *
3ARR3CT6W5 or AC85007* or RVA3AI3D
CK24K3-PFZ
PSC / CSCR
35 / 370 VAC
120/150 *
AC85007* or RVA3AI3D
CK27K3-PFV
PSC / CSCR
35 / 370 VAC
150-200*
3ARR3CT6W5 or AC85007* or RVA-3AI3D
CK30K3-PFV
PSC / CSCR
50 / 370 VAC
150-200*
AC85001M*
CK30K3-PFZ
PSC / CSCR
45/370 VAC
150/200 *
3ARR3CT6V5 or * AC85006 or RVA4L3D
CK32K3-PFZ
PSC / CSCR
45/370 VAC
150/200 *
3ARR3CT6V5 or * AC85006 or RVA4L3D
CR22K6M-PF1
PSC / CSCR
36
80/100 *
3ARR3CT3P5 or AC85004 or RVA3F6D*
CR30K6M-PF1
PSC / CSCR / PTCR#
45
150/200*
AC85001M*
CR36K6-PFZ
CSCR
40 / 370 VAC or 45 / 370 VAC
130-156/250 V-High Starting Torque 3ARR3CT3P5 or RVA3F6D 43-52/330 V-Low Starting Torque or AC85004
CR42K6-PFZ
CSCR
60/370 VAC or
189-227 / 330 V-High Starting Torque
3ARR3CT24S5 or
65/370 VAC
64-77/330 V-Low Starting Torque
RVA-3AG6D or AC85005
KCJ 511 HAE
PSC / CSCR
25
80/100 *
LT85002 *
KCJ 515 HAE
PSC / CSCR
36
80/100 *
AC85001M *
KCH 522 HAE
PSC / CSCR
36
80/100 *
AC85001M *
KCA 522 HAE under developement
PSC / CSCR
36
80/100 *
AC85004 *
KCH 523 HAE
PSC / CSCR
36
80/100 *
AC85004 *
KCH 524 HAE
PSC / CSCR
36
80/100 *
AC85001M *
KCH 528 HAE
CSCR
36
120/150
AC85004
* These are optional accessories to be used for CSCR circuit. # PTCR Model No. PTCR 305C20A or PTH 491A04 AR470N500. Note : All run capacitor should have rating 440 VAC and start capacitor 275 VAC surge, unless otherwise specified by Kirloskar Copeland Ltd. u All models have Internal Overload Protector. u All models have Internal Pressure Relief Valve except KCJ511HAE.
9
AIR CONDITIONING COMPRESSORS R22 ELECTRICAL SPECIFICATIONS PFV
MODEL
CK20K3
PF1
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
9.6
55
CK22K3 CK24K3
11
PFZ
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
8.80
51
TF5
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
9.7
51
RATED LOAD AMPS RLA
TFM LOCKED ROTOR AMPS LRA
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
3.1
17
4.3
23
6.1
45
56
CK24K3 CK27K3
12.9
65
CK30K3
14.5
65
CK30K3
12
58
CK32K3
14
58
CR22K6M
7.80
54
CR22K6M * CR30K6M
11.00
72
CR30K6M * CR36K6 CR36K6
13.6
85
15.4
104
CR42K6 CR42K6
4.9
41
6.1
45
* Under development.
ELECTRICAL SPECIFICATIONS B4
C4
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
RATED LOAD AMPS RLA
LOCKED ROTOR AMPS LRA
KCJ 511 HAE
4.7
25
KCJ 515 HAE
6.4
30
KCA 522 HAE *
8.6
54
KCG 554 HAE
7.2
44
KCG 562 HAE
8.5
49
KCG 572 HAE
10.2
55
KCH 522 HAE
3
17
4
22
MODEL
KCH 522 HAE
9.1
45
KCH 523 HAE
8.2
44
KCH 524 HAE
10
45
RATED LOAD AMPS RLA
D5 LOCKED ROTOR AMPS LRA
KCH 528 HAE KCH 528 HAE
10
13.6
48
AIR CONDITIONING COMPRESSORS R22 FULL RANGE COMPRESSORS “STANDARD” BILLS OF MATERIAL FOR THE INTERNATIONAL MARKET The bill of material includes features as shown by the X MODEL
CK20K3-PFV
BOM
FOUR LEGS 7.5" x 7.5" (190 x 190 mm)
101
x
201
FOUR LEGS 4.8" x 8" (122 x 203 mm)
121
x x x
201
x
601 CK24K3-PFZ
101
x x
201
x
601 CK27K3-PFV
101
x x
201
x
601 CK30K3-PFV
101
x x
201
x
601 CK30K3-PFZ
101
x x
201
x
601 CK32K3-PFZ
101
x x
201
x
601 CR22K6M-PF1
171
x x
621 CR22K6M-TFM
101
x x
601 CR30K6M-PF1
121
x x
621 CR30K6M-TFM
101
SERVICE VALVE
x
621 101
MOULDED PLUG
x
221
CK24K3-PFV
THREE LEGS 8.44" x 9.75" (214 x 248 mm)
x
601 CK22K3-PF1
THREE LEGS 6.12" x 8" (155 x 203 mm)
x x
601
x
CR36K6-TF5
121
x
CR36K6-PFZ
101
x
CR42K6-TF5
121
x
CR42K6-TFM
101
x
CR42K6-PFZ
101
x
11
AIR CONDITIONING COMPRESSORS R22 FULL RANGE COMPRESSORS “STANDARD” BILLS OF MATERIAL FOR THE INTERNATIONAL MARKET The bill of material includes features as shown by the X MODEL
BOM
KCJ 511 HAE
B421
FOUR LEGS 7.5" x 7.5" (190 x 190 mm)
FOUR LEGS 4.8" x 8" (122 x 203 mm)
B421
x x
B443
x x
B411
x x
B451
x
KCA 522 HAE
B412
X
KCH 523 HAE
B411
x
KCH 524 HAE
B411
B451
x x
B451 KCH 528 HAE
D511
x x
D551 KCH 528 HAE
C411
x x
C451 KCG 554 HAE
KCG 562 HAE
KCG 572 HAE
x
x
D551 KCH 522 HAE
x
D513
x
D511
x
D513
x
D511
x
D513
x
D511
x
x
x
x
BILL OF MATERIAL PROVISIONS Please refer to the bill of material shown on the previous page to view our standard offers of compressor selections. In addition to the marked features, each compressor will include the following : l l l l l
12
SERVICE VALVE
x
B423
D511
MOULDED PLUG
x
B441
KCH 522 HAE
THREE LEGS 8.44" x 9.75" (214 x 248 mm)
x
B441 KCJ 515 HAE
THREE LEGS 6.12" x 8" (155 x 203 mm)
Terminal box and cover Internal Line Break Protector. Internal Pressure Relief Valve except KCJ511HAE Grounding tab located in the terminal box. Mineral Oil Oil Charge : KCJ 511 HAE 30.6 Ounces (0.905 litres) KCJ 515 HAE 30.93 Ounces (0.915 litres) KCH & CK3 44.97 Ounces (1.330 litres) KCG 76.08 Ounces (2.250 litres) CR6 except 44.97 Ounces (1.330 litres) CR30K6M-PF1 55.12 Ounces (1.630 litres)
AIR CONDITIONING COMPRESSORS R22 DIMENSIONAL DRAWINGS CK3 RECTANGULAR MOUNT
SQUARE MOUNT
TRIANGULAR MOUNT
H
H
Model CK22K3/CK24K3 CK27K3 CK30K3 / CK32K3
Suction Tube ID inch mm 1/2 12.8 5/8 15.9 5/8 15.9
H mm 354.18 363.8 354.18
CR22K6M SQUARE MOUNT
TRIANGULAR MOUNT
13
AIR CONDITIONING COMPRESSORS R22 DIMENSIONAL DRAWINGS CR30K6M SQUARE MOUNT
TRIANGULAR MOUNT
5/8” (15.9 ID)
373
373
5/8” (15.9 ID)
CR36K6M SQUARE MOUNT
14
AIR CONDITIONING COMPRESSORS R22 DIMENSIONAL DRAWINGS CR42K6 (3φ) SQUARE MOUNT
(1φ) SQUARE MOUNT
KCJ 511 HAE RECTANGULAR MOUNT
15
AIR CONDITIONING COMPRESSORS R22 DIMENSIONAL DRAWINGS KCJ 515 HAE
RECTANGULAR MOUNT
TRIANGULAR MOUNT
KCH 523 HAE SQUARE MOUNT
16
TRIANGULAR MOUNT
AIR CONDITIONING COMPRESSORS R22 DIMENSIONAL DRAWINGS KCH
SQUARE MOUNT
Model KCH 528 HAE KCH 522 HAE (3φ) KCH 524 HAE KCH 522 HAE (1φ) KCH 515 HAE
H mm 381 357
Suction ID inch mm 5/8 15.9 5/8 15.9
357
1/2
TRIANGULAR MOUNT
Model KCH 528 HAE KCH 522 HAE (3φ) KCH 524 HAE KCH 522 HAE (1φ) KCH 515 HAE
12.8
H mm 372.4 372.4
Suction ID inch mm 5/8 15.9 5/8 15.9
349
1/2
12.8
KCG SQUARE MOUNT
12 UNF
17
AIR CONDITIONING COMPRESSORS R22 WIRING DIAGRAMS 1
CAPACITOR START CAPACITOR RUN(CSR) (CSCR)
PERMANENT SPLIT CAPACITOR (PSC/PTCR)
230 V, 50 Hz 1 Phase Supply
2
Glass Terminal
Run Capacitor
3
18
CAPACITOR START &RUN (CSR)FOR FORCR42K6-PFZ CR42K6-PFZ CAPACITOR START & RUN (CSCR)
PTCR (When requied)
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CK22K3-PF1
95°F (35°C) Ambient
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
-23.3 -10 2100 — — — —
-17.8 0 4508 3600 — — —
-12.2 10 7800 6500 5200 4400 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 11500 15300 20100 9810 13700 18400 8350 12400 16900 6980 11000 15300 5550 9520 13600
-23.3 -10 860 — — — —
-17.8 0 1070 1080 — — —
-12.2 10 1220 1230 1250 1180 —
Evaporating -6.7 20 1370 1410 1410 1390 1390
-23.3 -10 5 — — — —
-17.8 0 5.4 5.4 — — —
-12.2 10 6.0 6.0 6.0 5.6 —
7.2 45 22700 20900 19200 17875 15600
10 50 25400 23500 21600 19600 17500
12.8 55 28200 26000 23900 21800 19200
Temperature -1.1 4.4 30 40 1510 1600 1590 1710 1630 1780 1630 1840 1690 1910
7.2 45 1540 1760 1850 1925 2010
10 50 1700 1830 1930 2020 2120
12.8 55 1780 1920 2030 2130 2240
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 6.4 6.8 7.3 6.4 7.1 7.7 6.4 7.2 8.0 6.3 7.4 8.3 6.3 7.6 8.7
7.2 45 7.7 8.1 8.4 8.8 9.1
10 50 8.1 8.6 8.9 9.2 9.5
12.8 55 8.7 9.0 9.3 9.6 9.9
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
CK24K3-PFZ
Rated Voltage 220V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 14100 18200 22800 12500 16600 21100 10600 14600 19100 8870 12800 17100 7620 11400 15500
-23.3 -10 902 — — — —
-17.8 0 7010 5430 — — —
-12.2 10 10400 8840 6990 5290 —
7.2 45 25300 23500 21500 19800 17800
10 50 27900 28100 24000 21800 20100
12.8 55 30700 28900 26600 24400 26600
-23.3 -10 902 — — — —
-17.8 0 1140 1140 — — —
-12.2 10 1320 1370 1390 1270 —
Evaporating -6.7 20 1470 1560 1580 1570 1540
Temperature -1.1 4.4 30 40 1610 1740 1720 1860 1770 1940 1810 2010 1850 2100
7.2 45 1810 1920 2010 2100 2210
10 50 1890 1990 2080 2180 2310
12.8 55 1970 2070 2150 2260 2400
-23.3 -10 5.9 — — — —
-17.8 0 3.1 6.3 — — —
-12.2 10 6.5 6.7 6.7 6.4 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7.0 7.5 8.1 7.2 7.8 8.5 7.3 8.0 8.8 7.2 8.1 9.1 7.1 8.2 9.5
7.2 45 8.4 8.8 9.2 9.6 10.1
10 50 8.9 9.2 9.7 10.2 10.8
12.8 55 8.9 9.5 10.1 10.7 11.5
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
19
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CK30K3-PFZ
95°F (35°C) Ambient
Rated Voltage 220V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 17500 22700 27200 15900 20800 25300 14000 17700 23100 12150 17000 21200 10900 15100 18700
-23.3 -10 4950 — — — —
-17.8 0 8600 6700 — — —
-12.2 10 13000 10900 9600 7800 —
7.2 45 31400 28900 27000 24500 22300
10 50 34500 32200 30200 27900 25000
12.8 55 37800 35100 33000 30500 27700
-23.3 -10 1160 — — — —
-17.8 0 1430 1480 — — —
-12.2 10 1690 1780 1870 1610 —
Evaporating -6.7 20 1940 2000 2080 2150 2220
Temperature -1.1 4.4 30 40 2050 2210 2140 2340 2240 2460 2340 2600 2420 2730
7.2 45 2280 2430 2600 2725 2880
10 50 2330 2500 2700 2870 3030
12.8 55 2400 2540 2750 2970 3160
-23.3 -10 6.5 — — — —
-17.8 0 7.5 — — — —
-12.2 10 8.2 8.5 8.7 8.2 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 9.1 9.7 10.1 9.3 10.1 10.7 9.5 10.6 11.4 9.8 11.0 11.9 10.1 11.3 12.4
7.2 45 10.6 11.2 11.9 12.4 13.1
10 50 11.0 11.7 12.4 13.1 13.8
12.8 55 11.4 12.0 12.9 13.7 14.6
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
CK32K3-PFZ
Rated Voltage 220V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 18700 24200 29500 17000 22000 27300 15300 20300 25500 13600 18400 23200 11800 16300 20900
-23.3 -10 5700 — — — —
-17.8 0 9500 7900 — — —
-12.2 10 14100 11980 10700 9178 —
7.2 45 33300 31300 29200 26500 24400
10 50 37000 34800 32600 30200 27600
12.8 55 40900 38000 35700 33000 30700
-23.3 -10 1260 — — — —
-17.8 0 1550 1610 — — —
-12.2 10 1830 1930 2020 1740 —
Evaporating -6.7 20 2100 2170 2250 2330 2420
Temperature -1.1 4.4 30 40 2230 2390 2350 2530 2460 2680 2560 2820 2670 2950
7.2 45 2470 2630 2810 2950 3120
10 50 2520 2710 2910 3110 3280
12.8 55 2530 2750 2980 3210 3420
-23.3 -10 7.1 — — — —
-17.8 0 8.2 8.6 — — —
-12.2 10 9.1 9.35 9.6 8.5 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 10.1 10.8 11.3 10.4 11.3 12.0 10.6 11.9 12.75 10.8 12.3 13.4 11.1 12.7 14.0
7.2 45 11.9 12.55 13.2 14.0 14.8
10 50 12.3 13.1 13.9 14.7 15.6
12.8 55 12.8 13.5 14.5 15.5 16.5
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
20
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CR22K6M-PF1
95°F (35°C) Ambient
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140 65.6 150
-23.3 -10 2280 — — — — —
-17.8 0 5950 4830 — — — —
-12.2 10 9370 8200 7020 5800 — —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 12900 16600 21800 11600 15400 19900 10300 13900 18100 8920 12300 16200 7500 10400 14200 6050 8920 12200
-23.3 -10 750 — — — — —
-17.8 0 990 970 — — — —
-12.2 10 1170 1180 1170 1140 — —
Evaporating -6.7 20 1290 1340 1360 1370 1350 1310
7.2 45 24600 22600 20600 18500 16300 14100
10 50 27800 25600 23400 21100 18700 16300
12.8 55 31400 29000 26500 24000 21400 18700
7.2 45 1450 1590 1700 1750 1860 1900
10 50 1490 1640 1760 1870 1930 2010
12.8 55 1510 1680 1820 1940 2040 2120
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140 65.6 150
Temperature -1.1 4.4 30 40 1380 1440 1460 1550 1520 1650 1550 1720 1570 1770 1570 1800
CR30K6M-PF1
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140 65.6 150
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 17000 22400 28600 15300 20400 26300 13600 18500 24000 12000 16600 21800 10300 14600 19600 8680 12800 17400
-23.3 -10 5040 — — — — —
-17.8 0 8200 6870 — — — —
-12.2 10 12200 10600 9060 7550 — —
7.2 45 32000 29500 27100 24600 22200 19900
10 50 35600 32900 30300 27700 25100 22500
12.8 55 39400 36500 33700 30900 28100 25400
-23.3 -10 980 — — — — —
-17.8 0 11 9 0 11 8 0 — — — —
-12.2 10 1390 1410 1410 1390 — —
Evaporating -6.7 20 1660 1740 1800 1840 1850 1820
Temperature -1.1 4.4 30 40 1770 1840 1890 2000 1990 2140 2070 2260 2120 2360 2130 2410
7.2 45 1850 2040 2200 2350 2460 2540
10 50 1860 2060 2250 2420 2560 2660
12.8 55 1850 2080 2290 2480 2640 2770
-23.3 -10 5.5 — — — — —
-17.8 0 6.3 6.3 — — — —
-12.2 10 7.1 7.2 7.2 7.1 — —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 8.7 9.2 9.4 8.9 9.5 9.9 9.0 9.7 10.3 9.0 9.9 10.7 9.1 10.1 11 . 1 9.2 10.3 11 . 4
7.2 45 9.5 10.0 10.5 11 . 0 11 . 5 11 . 9
10 50 9.4 10.1 10.7 11 . 2 11 . 8 12.4
12.8 55 9.3 10.0 10.0 11 . 4 12.1 12.8
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140 65.6 150
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140 65.6 150
Production compressors to meet above nominal performance values within + 5%.
21
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CR36K6-PFZ
95°F (35°C) Ambient
Rated Voltage 220V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
-23.3 -10 6220 — — — —
-17.8 0 10400 8200 — — —
-12.2 10 15100 13100 11600 9100 —
-23.3 -10 1220 — — — —
-17.8 0 1490 1500 — — —
-12.2 10 1710 1740 1770 1810 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 20500 26700 33700 18400 24400 31200 16600 22200 28600 14200 19700 25900 12700 17800 23500
7.2 45 37600 34900 32100 29300 26600
10 50 41700 38900 35800 32900 29900
12.8 55 46200 43300 39700 36900 33400
7.2 45 2120 2330 2540 2720 2900
10 50 2120 2350 2590 2800 3010
12.8 55 2110 2360 2620 2860 3100
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1900 1980 2060 2090 2120
Temperature -1.1 4.4 30 40 2030 2100 2160 2280 2290 2470 2380 2620 2480 2770
CR42K6-PFZ
Rated Voltage 220V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 24000 31800 40700 21700 29000 37500 19400 26300 34300 17300 23700 311 0 0 15300 21200 28100
-23.3 -10 8800 — — — —
-17.8 0 12400 10900 — — —
-12.2 10 17500 15600 13800 12100 —
-23.3 -10 1490 — — — —
-17.8 0 1730 1740 — — —
-12.2 10 1980 2030 2060 2070 —
Evaporating -6.7 20 2210 2310 2390 2450 2500
-23.3 -10 — — — — —
-17.8 0 8.9 8.9 — — —
-12.2 10 9.9 10.1 10.2 10.3 —
Evaporating -6.7 20 10.9 11 . 3 11 . 6 11 . 9 12.1
7.2 45 45500 42000 38600 35200 31900
10 50 50600 46800 43100 39500 35900
12.8 55 56000 52000 47900 43900 40100
Temperature -1.1 4.4 30 40 2400 2530 2550 2740 2690 2940 2810 3 11 0 2910 3280
7.2 45 2570 2810 3030 3240 3440
10 50 2580 2850 3 11 0 3350 3580
12.8 55 2560 2860 3160 3430 3700
Temperature -1.1 4.4 30 40 11 . 8 12.4 12.4 13.3 13.0 14.1 13.5 14.8 13.9 15.6
7.2 45 12.5 13.6 14.5 15.4 16.3
10 50 12.6 13.8 14.9 15.9 16.9
12.8 55 12.5 13.8 15.1 16.3 17.5
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
22
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CR30K6M-TFM *
95°F (35°C) Ambient
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140 65.5 150
-23.3 -10 5040 — — — — —
-17.8 0 8200 6870 — — — —
-12.2 10 12200 10600 9060 7550 — —
-23.3 -10 980 — — — — —
-17.8 0 1190 1180 — — — —
-12.2 10 1390 1410 1410 1390 — —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 16900 22400 28700 15100 20300 26300 13300 18200 23800 11500 16100 21400 9840 14200 19100 8280 12300 16900
7.2 45 32100 29500 26900 24500 21800 19400
10 50 35700 32900 30100 27300 24700 22100
12.8 55 39500 36500 33500 30500 27700 24900
7.2 45 1770 1940 2110 2350 2380 2490
10 50 1760 1970 2160 2330 2490 2630
12.8 55 1740 1970 2190 2390 2580 2740
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140 65.5 150
Evaporating -6.7 20 1550 1620 1660 1680 1680 1660
Temperature -1.1 4.4 30 40 1680 1750 1790 1910 1880 2040 1950 2170 1990 2270 2020 2350
* Under development.
CR36K6-TF5
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
-23.3 -10 6170 — — — —
-17.8 0 10300 8690 — — —
-12.2 10 15000 13300 11500 9700 —
-23.3 -10 1200 — — — —
-17.8 0 1460 1450 — — —
-12.2 10 1690 1730 1740 1730 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 20400 26500 33500 18500 24300 30900 16500 22100 28400 14500 19900 25800 10700 15600 21000
7.2 45 37300 34600 31800 29100 23800
10 50 41500 38500 35500 32600 26900
12.8 55 45900 42700 39400 36200 33100
7.2 45 2090 2290 2490 2680 2850
10 50 2090 2320 2540 2760 2960
12.8 55 2070 2330 2580 2820 3050
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1860 1950 2020 2070 2090
Temperature -1.1 4.4 30 40 1990 2070 2130 2250 2250 2430 2360 2590 2440 2730
Production compressors to meet above nominal performance values within + 5%.
23
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CR42K6-TF5
95°F (35°C) Ambient
Rated Voltage 400V, 50 Hz, 3Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 24000 31100 39600 21700 28500 36500 19500 25900 33300 17200 23200 30300 15000 20600 27100
-23.3 -10 9400 — — — —
-17.8 0 12800 11500 — — —
-12.2 10 17800 11900 14200 12600 —
7.2 45 44400 41000 37700 34200 30900
10 50 49700 46000 42300 38500 34800
12.8 55 55400 51300 47300 43300 39200
-23.3 -10 1500 — — — —
-17.8 0 1675 1700 — — —
-12.2 10 1920 1950 1990 2020 —
Evaporating -6.7 20 2190 2290 2370 2410 2430
Temperature -1.1 4.4 30 40 2370 2480 2520 2700 2650 2980 2750 3040 2820 3170
7.2 45 2520 2770 2990 3300 3450
10 50 2550 2830 3070 3290 3490
12.8 55 2570 2880 3150 3400 3620
-23.3 -10 4.2 — — — —
-17.8 0 4.3 4.3 — — —
-12.2 10 4.6 4.7 4.8 4.9 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 4.8 5.0 5.2 4.9 5.2 5.6 5.0 5.4 5.8 5.1 5.5 6.0 5.2 5.6 6.2
7.2 45 5.2 5.6 5.9 6.1 6.3
10 50 5.2 5.6 6.0 6.2 6.5
12.8 55 5.3 5.8 6.2 6.5 6.8
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
24
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCJ511HAE
95°F (35°C) Ambient
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 5960 7120 10100 5240 6280 9180 4650 5540 8290 4210 4880 7440 — 4310 6610
7.2 45 11 9 0 0 11 0 0 0 10000 9100 8 11 0
10 50 13800 12800 11 7 0 0 10700 9650
12.8 55 15500 14500 13400 12300 11100
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 712 725 830 739 756 869 769 792 910 801 829 952 — 867 992
7.2 45 806 945 988 1020 1074
10 50 980 1020 1070 1110 1160
12.8 55 1050 1100 1150 1190 1240
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 3.8 3.9 4.2 3.9 4.0 4.3 4.0 4.1 4.4 4.1 4.2 4.5 — 4.4 4.7
7.2 45 4.4 4.5 4.6 4.7 4.9
10 50 4.5 4.7 4.8 5.0 5.1
12.8 55 4.7 4.9 5.0 5.2 5.3
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
KCJ515HAE
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7937 10530 13016 7303 9701 12188 6728 8921 11174 6211 8171 10150 — 7352 9341
7.2 45 15181 14303 13289 12470 11476
10 50 17170 16214 15278 14440 13582
12.8 55 19100 18008 17043 16175 15239
Temperature -1.1 4.4 30 40 1158 1225 1199 1269 1241 1313 1275 1354 1323 1399
7.2 45 1285 1326 1373 1420 1468
10 50 1339 1386 1427 1475 1528
12.8 55 1389 1437 1484 1528 1573
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 4.8 5.2 5.5 4.9 5.4 5.7 5.0 5.5 5.9 5.2 5.7 6.1 — 5.9 6.3
7.2 45 5.9 6.1 6.3 6.4 6.7
10 50 6.1 6.3 6.5 6.7 7.0
12.8 55 6.4 6.6 6.8 7.0 7.2
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1085 1117 1150 1184 —
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
25
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCH522HAE
95°F (35°C) Ambient
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 13300 17400 22100 11700 15800 20000 10300 13900 18000 8940 12200 16000 — 10600 14000
7.2 45 24700 22500 20400 17850 16000
10 50 27400 25200 22900 20500 18200
12.8 55 30400 28000 25600 23100 20500
Temperature -1.1 4.4 30 40 1500 1580 1586 1674 1680 1790 1770 1900 1864 2015
7.2 45 1640 1755 1880 2000 2120
10 50 1680 1816 1940 2050 2180
12.8 55 1720 1850 1970 2090 2215
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7.2 7.4 7.7 7.3 7.7 8.1 7.6 8.0 8.5 7.9 8.3 8.9 — 8.6 9.3
7.2 45 7.9 8.3 8.7 9.1 9.5
10 50 8.2 8.6 9.0 9.4 9.8
12.8 55 8.6 9.0 9.4 9.7 10.1
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1410 1484 1566 1630 —
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
KCH523HAE
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 14200 18300 23000 12200 16000 20400 11000 14500 18600 9840 13000 16800 — 11000 14500
7.2 45 25700 23000 21100 18800 15700
10 50 28800 26000 23900 21900 19300
12.8 55 32300 29400 27200 25000 22300
Temperature -1.1 4.4 30 40 1370 1520 1420 1570 1460 1620 1500 1670 1550 1730
7.2 45 1610 1670 1720 1780 1840
10 50 1700 1770 1820 1880 1950
12.8 55 1800 1860 1920 1990 2060
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 6.5 6.7 7.1 6.6 6.8 7.3 6.8 7.0 7.5 6.9 7.2 7.8 — 7.4 8.0
7.2 45 7.4 7.6 7.9 8.2 8.4
10 50 7.7 8.0 8.2 8.5 8.7
12.8 55 8.0 8.3 8.6 8.9 9.2
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1350 1380 1410 1440 —
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
26
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCH524HAE
95°F (35°C) Ambient
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 14500 18400 23400 12900 16600 21400 11400 14900 19400 9930 13200 17400 — 11600 15400
7.2 45 26200 24100 22000 19500 17600
10 50 29200 27100 24700 22300 19900
12.8 55 32400 30100 27700 25100 22400
Temperature -1.1 4.4 30 40 1710 1870 1790 1960 1890 2060 1980 2170 2080 2280
7.2 45 1960 2060 2170 2290 2400
10 50 2050 2160 2270 2390 2510
12.8 55 2140 2240 2360 2480 2600
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7.4 7.9 8.2 7.6 8.2 8.7 7.8 8.6 9.1 8.1 9.9 9.6 — 9.5 10.2
7.2 45 8.4 9.0 9.5 10.0 10.6
10 50 8.8 8.4 9.9 10.5 11.1
12.8 55 8.3 9.9 10.5 11.2 11.8
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1680 1750 1820 1900 —
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
KCH528HAE
Rated Voltage 230V, 50 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 17400 22600 28700 15600 20600 26300 13700 18200 23700 11600 15800 20900 — 13400 18200
7.2 45 32100 29500 26700 23300 20900
10 50 35700 33000 30000 26900 23900
12.8 55 39600 36700 33500 30300 27200
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 2040 2100 2170 2250 —
Temperature -1.1 4.4 30 40 2060 2290 2150 2410 2260 2540 2370 2660 2470 2780
7.2 45 2440 2560 2690 2800 2950
10 50 2570 2700 2830 2960 3080
12.8 55 2670 2800 2930 3060 3180
Evaporating -6.7 20 10.6 10.9 11.2 11.5 —
Temperature -1.1 4.4 30 40 11.1 11.8 11.4 12.2 11.8 11.6 12.2 13.1 12.7 13.6
7.2 45 12.2 11.6 13.1 13.6 14.1
10 50 12.7 13.2 13.7 14.2 12.8
12.8 55 13.3 13.8 14.3 14.9 15.4
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
27
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCH522HAE
95°F (35°C) Ambient
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 13200 17100 22000 11700 15300 20000 10500 13700 17900 8800 11900 16100 — 10400 14100
7.2 45 24800 22500 20300 17850 16100
10 50 27300 25100 23000 20700 18200
12.8 55 30400 27900 25700 23100 20400
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1220 1300 1365 1445 —
Temperature -1.1 4.4 30 40 1410 1445 1500 1550 1594 1680 1700 1790 1780 1880
7.2 45 1555 1660 1775 1850 1980
10 50 1675 1780 1890 2010 2125
12.8 55 1800 1900 2000 2100 2225
Evaporating -6.7 20 2.00 2.10 2.23 2.33 —
Temperature -1.1 4.4 30 40 2.10 2.24 2.20 2.40 2.31 2.60 2.50 2.81 2.63 2.99
7.2 45 2.39 2.59 2.81 3.00 3.20
10 50 2.59 2.79 3.00 3.15 3.35
12.8 55 2.63 2.85 3.07 3.29 3.50
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
KCH528HAE
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 17300 22400 28800 15700 20300 26250 13700 18000 23700 11500 15800 21000 — 14000 18250
7.2 45 32000 29500 26800 23300 21100
10 50 36000 33000 30000 27000 24000
12.8 55 39500 36400 33800 30400 27000
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1650 1760 1845 1950 —
Temperature -1.1 4.4 30 40 1900 1950 2030 2090 2155 2245 2290 2360 2400 2540
7.2 45 2100 2245 2400 2500 2720
10 50 2260 2400 2550 2690 2870
12.8 55 2430 2570 2700 2840 3000
Evaporating -6.7 20 2.61 2.80 2.94 3.15 —
Temperature -1.1 4.4 30 40 2.85 3.01 3.00 3.25 3.19 3.50 3.40 3.72 3.55 3.94
7.2 45 3.25 3.50 3.73 4.00 4.25
10 50 3.45 3.72 4.00 4.25 5.50
12.8 55 3.55 3.85 4.20 4.50 4.75
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
28
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCG554HAE
95°F (35°C) Ambient
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 31600 41800 53800 27000 36300 48000 23200 32100 43600 19800 28100 39000 — 23800 33800
7.2 45 60000 54600 49700 43875 38800
10 50 67500 61800 56000 50200 43400
12.8 55 75000 68800 63000 57200 50500
Temperature -1.1 4.4 30 40 3475 3800 3610 3980 3720 4150 3875 4360 4100 4600
7.2 45 3940 4132 4320 4450 4737
10 50 4090 4300 4490 4720 4960
12.8 55 4170 4400 4600 4820 5090
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 5.0 5.5 6.0 5.1 5.7 6.2 5.2 6.0 6.5 5.4 6.2 6.7 — 6.4 7.0
7.2 45 6.4 6.6 6.8 7.2 7.4
10 50 6.8 7.1 7.4 7.7 7.9
12.8 55 7.3 7.6 8.0 8.3 8.6
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 2800 2850 2960 3070 —
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
KCG562HAE
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 37800 50700 63100 32300 45100 57200 27400 39900 51400 22900 34900 45800 — 30100 40100
7.2 45 70300 64100 58100 50700 45800
10 50 78800 72300 65900 59400 52600
12.8 55 89100 82300 75400 66400 611 0 0
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 3500 3750 4420 3650 3860 4570 3730 3980 4720 3820 4100 4870 — 4220 5010
7.2 45 4800 4960 5130 5250 5440
10 50 5130 5310 5490 5660 5810
12.8 55 5360 5550 4740 5910 6080
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 6.0 6.6 7.1 6.1 6.8 7.4 6.2 7.1 7.7 6.4 7.3 8.0 — 7.6 8.3
7.2 45 7.5 7.8 8.2 8.5 8.8
10 50 8.0 8.4 8.8 9.1 9.4
12.8 55 8.7 9.1 9.5 9.9 10.2
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
29
50 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
KCG572HAE572HAE
95°F (35°C) Ambient
Rated Voltage 400V, 50 Hz, 3 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 11 0 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 43000 56000 72000 37000 50000 65600 31900 44000 59100 26800 38300 52300 — 32300 45000
7.2 45 81200 74000 67600 58320 52000
10 50 91000 63600 76200 68800 60400
12.8 55 102000 93800 86900 78000 70000
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 4180 4535 5180 4280 4680 5370 4365 4830 5535 4475 4975 5705 — 5120 5860
7.2 45 5580 5780 5970 6100 6280
10 50 6010 6230 6450 6640 6830
12.8 55 6260 6495 6720 6920 7160
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7.1 7.8 8.6 7.3 8.2 8.9 7.5 8.5 9.3 7.7 8.8 9.6 — 9.1 10.0
7.2 45 9.1 9.4 9.8 10.2 10.6
10 50 9.7 10.2 10.5 11.0 11.4
12.8 55 10.5 11.0 11.4 11.8 12.3
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
30
60 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CK22K3-PFVCGCK20K3-PFV
95°F (35°C) Ambient
Rated Voltage 230V, 60 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
-23.3 -10 3900 — — — —
-17.8 0 7400 5500 — — —
-12.2 10 10900 8900 7000 5500 —
-23.3
-17.8
-12.2
890 — — — —
1070 1120 — — —
1260 1350 1400 1190 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 14700 18900 22800 13000 16900 20900 10900 14700 18800 8900 12600 16500 7500 11100 14500
7.2 45 26700 24500 22100 20000 18000
10 50 30300 27700 25200 23000 21100
12.8 55 33700 31000 28800 26300 24400
7.2 (45) 1830 1920 2040 2140 2240
10 (50) 1890 2010 2130 2230 2340
12.8 (55) 1950 2070 2210 2310 2420
INPUT POWER (WATT) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 (20) 1490 1550 1600 1650 1730
Temperature -1.1 4.4 (30) (40) 1640 1730 1720 1830 1760 1900 1830 2000 1930 2110
CK24K3-PFV4K3-PFV
Rated Voltage 230V, 60 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 16900 22000 27100 14900 20100 25000 12900 18000 22800 11200 15800 20400 9900 14000 17800
-23.3 -10 4200 — — — —
-17.8 0 7500 6000 — — —
-12.2 10 12100 10100 8100 7000 —
7.2 45 30800 28700 26300 23500 20800
10 50 34300 31700 29300 26700 24100
12.8 55 36900 34500 31700 29000 26300
-23.3 -10 1080 — — — —
-17.8 0 1340 1320 — — —
-12.2 10 1588 1600 1620 1585 —
Evaporating -6.7 20 1800 1846 1876 1900 1920
Temperature -1.1 4.4 30 40 1920 2050 1980 2150 2060 2250 2140 2320 2190 2400
7.2 45 2140 2270 2380 2500 2580
10 50 2220 2380 2490 2600 2720
12.8 55 2280 2440 2570 2700 2800
-23.3 -10 6.0 — — — —
-17.8 0 6.3 6.6 — — —
-12.2 10 7.0 7.3 7.6 7.0 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 7.8 8.5 9.0 8.1 8.8 9.4 8.3 9.2 9.9 8.5 9.5 10.5 8.9 9.9 10.9
7.2 45 9.5 10.0 10.5 11.0 11.7
10 50 10.0 10.6 11.2 11.7 12.3
12.8 55 10.3 10.9 11.5 12.0 12.5
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
INPUT CURRENT (A) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Production compressors to meet above nominal performance values within + 5%.
31
60 HERTZ PERFORMANCE DATA
20°F (11.1°K) Superheat
AIR CONDITIONING COMPRESSORS R22
15°F (8.3°C) Subcooling
CK27K3-PFVK27K3-PFV
95°F (35°C) Ambient
Rated Voltage 230V, 60 Hz, 1 Phase
COOLING CAPACITY (BTU / HOUR) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
-23.3 -10 5400 — — — —
-17.8 0 9100 7700 — — —
-12.2 10 13600 11800 10200 8500 —
-23.3 -10 1310 — — — —
-17.8 0 1500 1560 — — —
-12.2 10 1750 1790 1840 1720 —
Evaporating Temperature -6.7 -1.1 4.4 20 30 40 19100 24500 29700 16800 22500 27600 15000 20500 25300 13100 18400 23200 11700 16500 21200
7.2 45 34200 31700 29100 26500 25000
10 50 37600 35500 33000 30900 28900
12.8 55 41700 39100 36500 33700 31700
7.2 45 2450 2590 2770 2900 3030
10 50 2540 2660 2820 2960 3140
12.8 55 2550 2740 2900 3010 3170
INPUT POWER (WATTS) Condensing Temperature °C °F 37.8 100 43.3 110 48.9 120 54.4 130 60.0 140
Evaporating -6.7 20 1970 2050 2100 2140 2210
Temperature -1.1 4.4 30 40 2210 2350 2300 2490 2390 2610 2460 2740 2540 2840
Production compressors to meet above nominal performance values within + 5%.
32
AIR CONDITIONING COMPRESSORS R22
33
KC SERIES COMPRESSOR NOMENCLATURE
AIR CONDITIONING COMPRESSORS R22
34
NOTES
35
NOTES
36