X-ray Digital CBCT Diagnosis Equipment - Sinclair Dental

0 downloads 109 Views 3MB Size Report
opment to present the best new solutions for this ever-advancing ... Odontogenic lesion visualization ... Intuiteve soft
X-ray Digital CBCT Diagnosis Equipment

Belmont Bel-Cat Selectable FOV

I-mode

Image is Everything Takara Belmont USA, Inc., the Worldwide Leader in Dental Equipment Manufacturing, as well as Salon and Spa Manufacturing, was founded in Japan in 1921. We at Belmont take tremendous pride in our rich and long history as an innovator and leader in the Dental market, which makes us strong, reliable, and here to stay. “Treating the customer with care” has been our philosophy since the company was established. Belmont continues to implement this philosophy by manufacturing products that are of the highest quality and finest craftsmanship at a reasonable cost to our customers, and by offering world-class product support. This has shown to be true with repeat loyal customers over several generations. We have been providing Dental Equipment to our loyal customers for forty-five years. As time has evolved and customer needs have changed, we have invested time and money on research and development to present the best new solutions for this ever-advancing marketplace. We are pleased to introduce the Bel-Cat, the latest addition to our Imaging Product Line. The Bel-Cat is a CBCT system that provides durability with flexibility, so you receive exceptional image quality today and for years to come. We are confident that this system is the best possible imaging system to care for your patients. D-mode

We truly believe Image is everything.

Clear image by 360o Rotation CBCT images taken by 360o rotation minimize the artifacts by metallic objects. The more the rotation angle is, the less distortion will appear, allowing you to obtain sharp and precise CBCT image.

This is an optimum function for implant or endodontic cases that require precise measurement. Bel-Cat provides two CBCT modes. Implant mode (I-mode) has a field of view of 79 mm (D) x 71 mm (H), covering the entire dentition. Dental mode (D-mode) has a field of view of 51 mm (D) x 51 mm (H). Voxel size is 0.1 mm, cabable of highly precise image.

3D MPR

3D MPR

Selectable Field of View Image only the necessary region of interest to provide better image quality and lower dose to your patients

CBCT Applications Panoramic image acquisition

Dental Volume Reformat

180o Rotation Orthodontic evaluation

Implant site assessment

Paranasal sinus evaluation

3rd molar impactions

Odontogenic lesion visualization

Impacted teeth

Trauma evaluation

Pathology

TMJ visualization

Oral surgery

Surgical guides

Mandibular canal localization

Impacted Teeth Image below

360o Rotation

with FPD

Bel-Cat provides a panoramic image in 2D or 3D

Lateral TMJ

Panoramic

Database

OnDemand3D Features • • • • • • • • • • •

OnDemand3D Streaming Implant Planning 3D Zoom Segmentation Virtual Camera Stitching (Option) Superimposition Create a movie clip X-Ray Simulation Report nVidia 3D Vision

OnDemand software provides 2D and 3D software in one package.

3D Image

Scout

Intuiteve software for generation of all necessary views, marking of mandibular nerve canal Datasets are saved as DICOM files transfer of 3D volume files in DICOM3 format for any further desired process ing (Implant planning) 3D Rendering software included Implant library is included

In2Guide Exposure Screen

Easy and precise positioning

Standard Features • • • • •

Clear image with fixed flat panel o 360 rotation minimizes artifact Easy to position patients accurately Scout image Small footprint

Forehead rest is designed to fit patient’s head firmly to provide accurate and clear images Positioning of the patient is easy and accurate, as the operator can stand face-to-face to the patient

Alignment with laser 3 laser lines for patient alignment ensures patient positioned correctly in FOV eliminating retakes

Stable and accurate positioning provides exceptional image quality Scout screen

Variable combinations of functions made to order Variable combinations of functions made to order Model

Bel-Cat

Bel-Cat PA

CBCT (FPD) Panoramic (FPD)

Bel-Cat CM

Knob for adjusting Head Support

large, easy-to-operate knob can adjust the head support by one turn.

Handle

Scout screen in the preview mode allows you to adjust the position of the head on the screen. It ensures accurate, easy and fast patient positioning prior to scan. It saves time and radiation dose.

Handle is designed for patient to hold easily.

Panoramic (CCD)

Simple operation panel for positioning

Cephalometric (CCD)

Sliding unit up/down

Beam positioning mode

Programs • • • • •

CBCT D-mode 51mm x 51mm CBCT I-mode 79mm x 71mm Panoramic TMJ Cephalometric

Frankfort beam up/down Base is accessible by wheelchair

Reset to the initial positon for patient introduction

Indicator beam forward / back

Panoramic with CCD sensor (Bel-Cat PA and Bel -Cat CM only) Panoramic Height of CCD

147 mm (H)

Exposure mode

Adult, Child and Orthoradial Panoramic Radiograph

Magnification Ratio

x 1.25

Exposure time

High speed : 9 sec, Normal : 12 sec.

4 section views of TMJ (Lateral) Height of CCD

147 mm (H)

Magnification Ratio

x 1.21

Exposure time

3 sec. x 4

2 section views of TMJ (Frontal) Height of CCD

147 mm (H)

Magnification Ratio

x 1.7

Exposure time

3 sec. x 2

Maxillary sinus

CCD Panoramic

Height of CCD

147 mm (H)

Magnification Ratio

x 1.21

Cephalometric with CCD sensor (Bel -Cat CM only) Cephalometric Exposure area

Highly precise panoramic image can be taken with CCD sensor. Bel-Cat PA comes with an CCD sensor for panoramic image. This can be attached in front of FPD

Lateral, Normal Lateral, Short mode Frontal

Detachable CCD Sensor for Panoramic

250 mm (W) x 220 mm (H) 180 mm (W) x 220 mm (H) 200 mm (W) x 220 mm (H)

Magnification Ratio

CCD 4 section TMJ (Lateral)

CCD 2 section TMJ (Frontal)

CCD Maxillary Sinus

x 1.1

Exposure time Lateral, Normal Lateral, Short mode Frontal

4 sec. 2.9 sec. 4 sec.

Bones of Carpus (Optional)

Bel-Cat CM comes with an CCD sensor for cephalometric and panoramic image. This can be attached in front of FPD, or to the cephalometric unit.

Exposure area

200 mm (W) x 220 mm (H)

Magnification Ratio

x 1.01

Exposure time

4 sec.

Foot Print (Bel-Cat CM) 28”

61”

87”

CCD Cephalometric 2.9 sec. (Lateral)

CCD Cephalometric 4.0 sec. (Lateral)

52”

6”- 8”

Dimensions (Bel-Cat CM)

75”

CCD Cephalometric 4.0 sec. (Frontal)

CCD Bones of carpus 4.0 sec. (Optional)

86"

35”- 69” 60” - 93”

93”

16”

Foot print (Bel-Cat and Bel-Cat PA)

Product Name

Bel-Cat Series

Rated Voltage

120V 60 Hz

Power Requirement

2.0 kVA (120V 20A breaker)

High voltage generator

Direct voltage

Tube voltage

60 - 95 kV (1kV step)

Tube current

2 - 12mA (1mA step)

Focal Spot

0.5 mm

Total filtration

2.5 mmAl (min)

Positioning indicator

3 laser lights

58-1/4”

58-1/4”

Device Specifications

CBCT D mode F.O.V.

51mm x 51 mm (H)

Area covered

L8 to R8, , L-TMJ, R-TMJ

Voxel Size

0.1 mm

Exposure time

8.5 sec. / 180o , 17 sec. / 360o *(note)

Dimensions (Bel-Cat and Bel-Cat PA)

79 mm x 71 mm (H)

Area covered

L8 to R8, L-TMJ, R-TMJ

Voxel Size

0.155 mm

51-1/4”

F.O.V.

5-7/8”-7-7/8”

I mode

8.5 sec. / 180o , 17 sec. / 360o *(note)

Exposure time o

*The rotation may be 270 depending on the patient positioning

Panoramic with FPD

19-3/4" 39-3/4"

Panoramic Height of FPD

130 mm

Exposure mode

Adult and child

Magnification ratio

x 1.25

Exposure time

16.8 sec.

16”

Exposure time

3 sec. x 4

85-1/2"

x 1.21

59-3/8”-93”

130 mm

Magnification Ration

35-1/4” - 69”

Height of FPD

92-5/8”

4 section veiws of TMJ (Lateral)

Belmont Equipment Divison of Takara Belmont USA Inc. 101 Belmont Drive, Somerset, NJ 08873 Phone : 1-800-223-1192 www.belmontequip.com ETL Classified Models, specifications, prices and warranty policies subject to change without notice BRH00053 REV021012

Takara Company Canada Ltd. 2076 South Sheridan Way, Mississauga ON, L5J 2M4 Phone : 1-905-822-2755 http://dental.takarabelmont.ca